Style: Pressure Switch, Body Size: AC40, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: MPa, Body Type: Standard
Size: 40, Options: 0.1 to 0.6MPa Set Pressure Range
Size: 40, Options: Scale Plate Pressure Unit: Both MPa and psi
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The standard IS10M pressure switch cannot be set to 0.4 to 0.45 MPa because 0.4 MPa is the upper limit of the set pressure range.
For AC-A/AC-B series modular F.R.L units with a white body, the pressure switch must be replaced with an IS10M-□-6-A pressure switch (set pressure: 0.1 to 0.6 MPa).
Thread: R, Seal: S (Seal), Options: LP (L + P)
Thread: N (NPT), Seal: None, Options: LP (L + P)
Thread: N (NPT), Seal: S (Seal), Options: LP (L + P)
Thread: R, Seal: None, Options: LP (L + P)
Part Number Description: FITTING Product Line: C Product Line Description: CONNECTORS Family Code: 700 Family Description: D SELF ALIGN FITTINGS Class Code: LP Part Code: 1 Reference Code: C Click here to report information errorImage shown may not match exact part number
There are 10 styles available including electroless nickel plated for copper-free applications., FITTING W/CHECK, CONNECTORS, KC SELF SEAL FITTINGS, LP, KC 12MM, .06298 lb
"1/4"" LP FNPT STRAINR, UTC SPECIAL DESIGN