SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-N-P-N01-LBK"

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE20, CB, ISE20 1/8 INCH NPT VERSION, 0.26455 lb

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE20, CA, ISE20 1/8 INCH PT VERSION, 0.26455 lb

This is a legacy product, and replaced byZSE20F-N-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .17857 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature

This is a legacy product, and replaced byZSE20-N-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .34645 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, "PRESSURE SWITCH

(When replacing the piping adapter ZS-46-N, tighten it using the same method.) Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

(When replacing the piping adapter ZS-46-N, tighten it using the same method.) Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

(When replacing the piping adapter ZS-46-N, tighten it using the same method.) Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm.

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, ISE20, "PRESSURE SWITCH, N lb

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, ISE20, "PRESSURE SWITCH, N lb

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, ISE20, "PRESSURE SWITCH, N lb

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: None, Option 3: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)