Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type)
Piping Variations With one-touch fittings (C4, C6, C8, N7) Female thread (01, 02, N01, N02, F01, F02) Straight (Nil) Bottom (L) Straight (Nil) Bottom (L) Without flow adjustment valve (Nil) S 1 2 S 1 2 S S 1 1 2 2 IN 1 IN 1 IN IN With flow adjustment valve (S) S S 1 2 1 2 S S 1 1 2 2 IN IN 1 IN 1 IN 906 2-Color Display Digital Flow Switch Series PFM7 Option 1 Nil With lead wire with connector
IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.
P Peak value display Displays the maximum pressure reached up to that moment. Piping-port size The size of the port on the switch body with which a device can be connected.
() N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I 1 W Z (2 m) (2 m) + () 2 R S () () T V () () A A B B -11No.PF-OMJ0005CN-I IN OUT X693 IN OUT 73 IN OUT
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
output PNP open collector 1 output NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current output Symbol A B C D ARM ARP Accessory (Pressure gauge) Pressure Switch Specifications Nil None IR1000 series: G33--01 IR2000 series: G43--01 IR-A Set pressure range (MPa) 0.1 to 1 G Resolution of setting and display (MPa) 0.001 IR IR 12 to 24 VDC10%, Ripple (p-p
T Stations Accessory (Pressure gauge) For high/low temperature environments 2 2 stations Nil None ... ... IR1000: G33--01 IR2000: G43--01 T L For high temperature For low temperature G 8 8 stations Body size Accessory (pressure gauge) is included, (but not assembled).
vacuum) (compound) (positive pressure) Rated pressure range 0.0 to -101.0 kPa -100.0 to 100.0 kPa -0.100 to 1.000 MPa Set pressure range 10.0 to -105.0 kPa -105.0 to 105.0 kPa -0.105 to 1.050 MPa Withstand pressure 500 kPa 500 kPa 1.5 MPa Minimum display unit 0.1 kPa 0.1 kPa 0.001 MPa Applicable fluid Air, inert gases and incombustible gases Power supply voltage 12 to 24 VDC 10%, ripple (p-p
output P PNP open collector 1 output Symbol Description Nil Units selection function1 M SI unit only2 P Units selection function (Initial value psi)1 1 Under the New Measurement Act, switches with the units selection function are not permitted for use in Japan. 2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Symbol Description
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)
Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
G46 P10 N02 G36 P4 N01 G46 P4 N02 1348110A B Regulating pressure range Bracket 0.05 to 0.85MPa 0.05 to 0.30MPa 0 1 ARX20 Nil F ARX21 Nil F Thread type G Pressure gauge Rc NPT G Nil N F ARX20N ARX21N P Port size Panel nut 1/8 1/4 01 02 Option combination numbers Panel nut is also included with B.
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type)
B G P BG GP 1 Specialty Regulators ARX Series Regulator for 290 psi (2 MPa) ARX20, 21 Flow Characteristics ARX20-N02 130.5 ARX20-N01 Conditions: Supply pressure 290 psig 130.5 116 116 101.5 101.5 Secondary pressure (psig) Secondary pressure (psig) 87 87 72.5 72.5 58 58 43.5 43.5 30 30 15 15 0 3.5 7.1 10.6 14.1 17.7 21.2 24.7 28.3 31.8 35.3 0 3.5 7.1 10.6 14.1 17.7 21.2 24.7 28.3 31.8 35.3
ASP-X369 Series Compact With One-touch Fitting Wide size variations
-K1K-01-X56 GZ33-P1C-N01-X55 kPa inHg/psi -100100kPa -30inHg14psi R1/8 NPT1/8 3F.S ,5F.S [g] ZL3 ZL6 390 470 +80 +25 +20 +60 / +120 , +80 +30 +60 22 No.ZL3-OM00801-A 9.5 ZSE10 [kP] -1010 -100100 /[kPa] -10110 -105105 [kPa] 500 [kPa] 0.1 [DCV] 122410%(p-p)10% [mA] 40 NPN NPN PNP PNP 2 OUT1: OUT2: [mA] 80 [V] 28(NPN ) 26.4(NPN ) [V] 2 (80mA ) [ms] 2.5 (20,100,500,1000,2000ms
output P PNP open collector 1 output Symbol Description Nil Unit selection function1 M SI unit only2 P Unit selection function (Initial value psi)1 1 Under the New Measurement Act, switches with the unit selection function are not permitted for use in Japan. 2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Symbol Description
(See Figure on page 59) Switch output NPN or PNP open collector output: 1 output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. applied voltage 28 V (NPN output) Residual voltage 1 V or less (at 80 mA load current) 4 ms or less (with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 10 s, 30 s or 60 s selected) Delay time Short circuit protection Provided
NPT AR24P-320AS-01 Rc (14) Plug assembly Including part (13)) AR24P-320AS-N01 NPT AR24P-320AS-F01 G The numbers in the table and structural drawings are consistent with the numbers in sections [10.