sggT 3 Lr 33 51 75 96 117 138 159 180 La ,15 6 al 1(F 12S r50 171 IQ 44 suction filter and silencer valve retease vatve vacuum switch (solid-state or diaphragm) Pnessune to-21iFllg (-030 mmllD. nozzle diameters for efficient aoolication. floul Incnemed by 40%. ) nozzle suction flow is 40% higher than nal designs. &Lig[tweignt. 15.5mm) width; 0.881bs. (4009f) weight.
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Piping: NPT1/4, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: With Unit Display Switching Function, Option 1: L [Lead Wire with M12 Connector (5m), Right-Angled], Option 2: With Bracket
Piping: NPT1/4, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: With Unit Display Switching Function, Option 1: L [Lead Wire with M12 Connector (5m), Right-Angled], Option 2: With Bracket
Piping: NPT1/4, Output: 27 [NPN Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: With Unit Display Switching Function, Option 1: L [Lead Wire with M12 Connector (5m), Right-Angled], Option 2: With Bracket
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type])
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
(PAP331) Besides, sidebody and port are made of molded piece, that has enabled to generate lower particulate. 1 N Diaphragm material 1 With silencer AN200-02 for Air EXH. 2 When NPT port thread is necessary, use AN200-N02. 1 PTFE Long service life Operating method Durability has been improved by adopting the denaturated PTFE for the diaphragm.
SS5YJ3-32, S32Station -M5 Stations L1 L2 SS5YJ3-32, S32Station -C4 3 52 44 6 83.5 75.5 8 104.5 96.5 10 125.5 117.5 20 230.5 222.5 2 41.5 33.5 4 62.5 54.5 5 73 65 7 94 86 9 115 107 11 136 128 12 146.5 138.5 13 157 149 14 167.5 159.5 15 178 170 16 188.5 180.5 17 199 191 18 209.5 201.5 19 220 212 Stations L1 L2 3 53 44 6 84.5 75.5 8 105.5 96.5 10 126.5 117.5 20 231.5 222.5 2 42.5 33.5 4 63.5
W~igh L2 L..3, ~L ~ "A1 '" , 'A2 oM II'. I '-1 'N . ,." " H1 H2 01 02 03 l1 M odel ~ T1 T2 ' ~ f . 9 4 ' 3 ~9 . 2~q .. ~ " 6 8" 41,-'1; " W }?'.." 48.7' 42.6, 10.9 46.4 2B,2 " . . '118:'7 ~7 .3 .70~ .2M ..