(a) Delta connection For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage between a pair of lines (e.g. between L1 and L2) among voltages between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1).
Symbol Connection target (application) Description Supply the following power to L1, L2, and L3. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. Driver LECSS2-T5 to Power LECSS2-T9 L1/L2/L3 Main circuit power 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L2/L3 supply 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L3 P3/P4 Connect P3 and P4.
M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9 90.2 91.9 90.2 91.9 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5
M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5 23.3 26.5 23.3 26.5 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9
VBA10A-N02 VBA10A-T02 : when -Z VBA43A-N04 VBA43A-T04 : when -Z G27-20-01 G27-P20-01 AN200-N02 VBA20A-N03 VBA20A-T03 : when -Z VBA40A-N04 VBA40A-T04 : when -Z VBA22A-N03 VBA22A-T03 : when -Z VBA42A-N04 VBA42A-T04 : when -Z VBA11A-N02 VBA11A-T02 : when -Z Model Description Pressure gauge : when Nil Pressure gauge : when -Z Note 4) G36-10-N01 G36-P10-N01 AN300-N03 ANA1-N03 KT-VBA22A-7N KT-VBA22A
-*309(0x0135) ISE75G-*-L2-*320(0x0140) ISE76G-*-L2-*321(0x0141) ISE77G-*-L2-*322(0x0142) ID ISE78G-*-L2-*362(0x016A) 1(0 ms) 2 3 ISE70G/ISE75G MPa/kPa ISE76G/ISE77G/ISE78G MPa 490 5https://www.smcworld.com 6 02 N02 F02 Rc1/4 NPT1/4 G1/4 Al2O3(96) ISE70GC3604()FKM+ ISE75G/ISE76G/ISE77G/ISE78GC3604()FKM ISE70G 179 g 178 g 175 g ISE75G/ISE76G/ISE77G 184 g 183 g 181 g M12 139 g -87No.PS-OMV0008CN-E
Applicable tubing O.D. d L2 L3 M AQ ASV AK D2 L1 VCHC ASS T2 L4 H1 ASR ASQ (Hexagon width across flats) H2 KE (Hexagon width across flats) TMH D3 A1 L5 D1 A2 T1 Inch Size L4 (1) Mass (g) A1 (2) A2 (2) D3 L3 L2 L1 M d T1 D1 H1 H2 D2 Max. Min.
Wa = K Wmax Workpiece mounting coefficient K: Fig. (3) Allowable load weight coefficient : Graph (1) Max. allowable load mass Wmax: Table (2) 1 = W/Wa Wa = 1 x 1 x 4 = 4 K = 1 = 1 Wmax = 4 1 = 1/4 = 0.25 3-2 Load Factor of the Static Moment Rolling Yawing Examine My. My = 1 x 9.8 (10 + 30)/1000 = 0.39 A3 = 30 May = 1 x 1 x 18 = 18 Mymax = 18 K = 1 = 1 2 = 0.39/18 = 0.022 Examine Mr.
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration
AK Applicable tubing O.D. d L2 L3 M Inch size ASS ASR D2 L1 ASF T2 L4 H1 H1 (Hexagon width across flats) (Hexagon width across flats) H2 H2 (He (Hexagon width across flats) xagon width across flats) (Hexagon width across flats) D3 A1 L5 D1 A2 T1 Inch Size L4 Weight (g) d T1 D1 A2 A1 D3 M L3 L2 L1 H1 H2 D2 Max. Min.
4 24 17 28.6 70.3 61.8 ASP630F-04-12S-X369 12 21.7 35.2 49.5 25 21.8 ASP330F-N01-07S-X369 NPT1/8 10-32UNF 12 8 14.2 23.9 31 13.6 38.6 35.2 16.8 1/4 13.2 ASP430F-N02-07S-X369 25.2 34.4 18.3 16.8 ASP430F-N02-09S-X369 5/16 15.2 27.2 36.4 18.4 18.7 17.46 12.7 18.5 48.7 42.4 NPT1/4 ASP430F-N02-11S-X369 3/8 18.5 35.3 44.5 19 20.8 NPT1/8 ASP530F-N03-09S-X369 5/16 15.2 29.7 41.2 18.7 NPT3/8 19 12
11 One-touch Screw-in One-touch N01 N02 N02 Screw-in Screw-in Screw-in ZH15DA08 10 10 One-touch One-touch One-touch 08 03 10 One-touch Screw-in One-touch 02 03 03 Screw-in Screw-in Screw-in ZH15DA09 11 11 One-touch One-touch One-touch 09 N03 11 One-touch Screw-in One-touch N02 N03 N03 Screw-in Screw-in Screw-in ZH18DA10 12 12 One-touch One-touch One-touch 10 03 12 One-touch