Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I T H O N E-T O U C H F I T T I N G S D I M E N S I O N S (N)AS1000-4000 Model Applicable D1 D2 L1 L2
E U N I T T Y P E D I M E N S I O N S S I N G L E U N I T: DIN R A I L M O U N T No. of Sensors 2 3 4 5 6 L1 70 105 140 175 210 L2 105 140 175 210 245 L3 140 175 210 245 280 No. of Sensors 2 3 4 5 6 L1 70 105 140 175 210 L2 36 71 106 141 Courtesy of Steven Engineering, Inc. !
LED/24 VDC Port size Nil 02 N02 With gasket Rc 1/4 NPT 1/4 Note) Micro load type: Not available L2 option. 864 Pneumatic Pressure Switch Series IS3000 Construction Precautions IS3000-02/3010-02 (Rc 1/4 thread) Be sure to read before handling.
Light Assembly For 110 VAC: 1530118-1 220 VAC: 1530118-2 24 VDC: 1530118-5 Able to convert into L1, L2, L5 by changing each light assembly. 16-9-4
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation Manual + Calibration