Mounting Method: 0 (1/4 Thread Connection), Load Capacity: 0 (Standard), Port Size: N02 (1/4 NPT), Indicator Light: L2 (Neon Lamp/220VAC)
Mounting Method: 0 (1/4 Thread Connection), Load Capacity: 0 (Standard), Port Size: N02 (1/4 NPT), Indicator Light: L2 (Neon Lamp/220VAC), Pressure Display: P (MPa and psi)
This is a legacy product, and replaced byISE70-N02-L2, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .74287 lb
manifold H O W T O O R D E R NZM V A C U U M E J E C T O R M A N I F O L D (N)ZZM B NUMBER OF STATIONS 01 ... 1 Station 02 ... 2 Stations to 10 ... 10 Stations EXHAUST PORT 04 ... 1/2 06 ... 3/4 PORT THREAD Nil ...PT* Remove (N) when ordering T .NPTF Fitted with an Optional Silencer Series NAN: see section Air Preparation Accessories n 1 2 3 4 5 6 7 8 9 10 L1 28 44 60 76 92 108 124 140 156 172 L2
Memory map of input data Data (2 byte) Input area Branch connector (INPUT) MSB LSB MSB LSB 15 8 7 0 byte (b+1) byte (b) Word (a) COM A byte (b+3) byte (b+2) Word (a+1) COM B byte (b+5) byte (b+4) Word (a+2) COM C byte (b+7) byte (b+6) Word (a+3) COM D (a, b=0 to) Memory map of output data Data (2 byte) Output area Branch connector (OUTPUT) MSB LSB MSB LSB 15 8 7 0 byte (d+1) byte (b) Word
Memory map of output data Data (2 byte) Output area Branch connector (OUTPUT) MSB LSB MSB LSB 15 8 7 0 byte (d) byte (d+1) Word(c) COM A byte (d+2) byte (d+3) Word(c+1) COM B byte (d+4) byte (d+5) Word(c+2) COM C byte (d+6) byte (d+7) Word(c+3) COM D : : (c, d=0 to) NOTE Read carefully the user manual of PLC which is used as a master.
Enable Byte order of process Process data data within one word The data format of process is assumed to be LSB-MSB. Port Disable 7 format (Input data) Process data size of input 1 to 32 Setting the input data size 0 *1 The data format of process is assumed to be MSB-LSB. Enable Byte order of process data within one word Process data The data format of process is assumed to be LSB-MSB.
LSB) 0x0C FunctionID 1 (MSB) R Fixed at 0x0. 0x0D FunctionID 2 (LSB) 0x0E Reserved R Fixed at 0x00.
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only)
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -