SMC Corporation of America
Elite Part Number Search
Search Results "KM14-04-06-03S-3"

Metric size Inch size 0 1 Meter-out Meter-in 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 23 04 06 08 10 12 4 6 8 10 12 With One-touch fitting Stainless steel specifications (SUS303) Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Use 1/8" tube.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

Run Thermo chiller Stop 1 5 Circulating fluid 4 temperature 600sec 500sec AS.04 2 set temperature 16oC Circulating fluid set temperature 15 oC 3 AS.06 250sec set temperature 14oC AS.04 Alarm monitoring ON OFF ON AS.06 Alarm monitoring OFF Generation Alarm Nothing Elapsed time Fig 5-3: Alarm generation timing Alarm generation timing Status (1): Temperature alarm monitoring starts by starting

AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 4 Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside

Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).

0.31 0.22 0.27 0.18 0.39 Cv 3.0 4.1 3.0 4.1 3.5 4.2 3.6 4.6 1 2 VSA4140-04 VSA4140-06 VSA4240-04 VSA4240-06 VSA4340-04 VSA4340-06 VSA4440-04 VSA4440-06 1 8 Rc 2 position single SA 1 2 1.31 1 8 Rc 3 4 1 2 1 8 Rc 2 position double 3 position closed center 1 2 1.50 VA 3 4 1 2 3 4 1 2 3 4 1 8 Rc 1 8 Rc 1 2 1.73 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,

Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I

Modification of the detecting position should be made in the condition of 3. CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 1/2 3/4 1 1 1/4 1 1/2 2 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 2.7 2.7 2.7 5.1 5.1 5.0 10.3 10.3 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 56 56 56 76 76 76 101 101 71 71 71 104 104

3/4 1 Thread type ON-flow range Note 1) IF30 is available for 06.

P = 11.5 1 2 3 4 5 6 7 8 ... n: Stations 40.5 Silencer cover L Blanking plug (for One-touch fitting) Dimensions Applicable fitting size d 3.2 4 6 8 A 23 04 06 08 Model A L D KQ2PKQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 This is inserted into cylinder ports and SUP and EXH ports that are not used.

mountable number 3 port valve mountable number 00 02 04 00 02 04 No 2 port valves used 2 pcs.

ground Type 3 ground Type 3 ground Type 3 ground b) 3-wire type Wiring with signal ground line (SG) Master unit Slave unit 01 Slave unit 03 Slave unit 75 Type 3 ground Type 3 ground Type 3 ground Type 3 ground Twisted pair with shield Type 3 ground Type 3 ground Type 3 ground Type 3 ground 1-6-113 114 Type SF1 NKE Corporation Uni-wire System Type SJ1, SJ2 SUNX Corporation S-LINK System Type

L4 Note) Weight (g) 3 5 5.5 6.5 8.5 9.5 19 22 36 38 42 44 76 82 Model D1 Applicable tube O.D. d AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 D2 D3 D4 L1 L2 L3 L5 L6 L7 L8 M1 MIN. 18.4 21 21.7 22.7 25.4 26.5 28.2 29.5 33.6 34.4 36 37.1 44.1 45.1 6 8.4 9.3 11.6 9.3 11.6 12.8 15.2 13.2