A A1 RR1 A1 E1 L1 MM RR1 U1 NZ L Part no.
L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max.
78.5 42.5 DIN rail holding screw (For DIN rail mounting) (Station n1) (Station 1) (Station 1) (Station n2) Light/surge voltage suppressor Individual SUP spacer Individual EXH spacer 63.5 60 52.5 12 (For DIN rail mounting) (7.5) n1 = Valve stations n2 = Input block stations L2 = L1 10.5 L3 = 16 x n1 + 60 L4 = L3 + 81 + 21 x n2 L5 = (L1 L4)/2 L6 = 16 x n1 + 48 L7 = 21 x n2 + 81.5 L1: DIN
In this case, please note that dimensions, L1 and L2 on pages 160 and 161 may vary slightly.) For other components, refer to the SY series of the WEB catalog.
CRB2 CRB2 Q1 = M Q1 = M CRB1 L1 = L1 = MSU L1 L1 Q1 Q1 CRJ Not available for size 10 Not available for size 10 The maximum dimension L1 is, as a rule, twice the thread size. (Example) For M5: L1 max. = 10 mm The maximum dimension L1 is, as a rule, twice the thread size.
Allowable dynamic moment Model Mounting orientation LJ1H20 Actuator rating Load movement direction 8kg 500mm/s 600mm Work load Maximum speed Maximum stroke 600 400 L1 (mm) a = 1000 Pitching Yawing Vertical Vertical m a a = 2000 a = 3000 200 LJ1H2022PA-K (Power supply voltage 200VAC) L1 Mep 0 5 10 15 Transfer load m (kg) When an actuator is operated under conditions that exceed the lines in
Slave unit 75 Slave unit 03 Slave unit 01 Master unit ZW-31LM SI unit Master unit SI unit Master unit SI unit SI unit SHIELD SG L2 L1 SHIELD SG L2 L1 SHIELD SG L2 L1 SG L2 L1 + + FG + + FG + + + + + + SHIELD FG FG + Twisted pair wire with shield Class 3 ground Class 3 ground Class 3 ground Class 3 ground FG FG b) 3 wire type Wiring does not include signal ground line (SG).
= 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1.
Formula: L1 = 16n + 57, L2 = 16n + 176 (For one input block.
P = 10.5 15.5 L1 L2 4.5 (Station 1) (Station n) 15.5 (Light/surge voltage suppressor) (Light/surge voltage suppressor) + + + + + + + + + + B B 20 15 5 A A B B 20 1 5 15 (Pitch) P = 10.5 M5 x 0.8 (A, B port) A A One-touch fitting (A, B port) Applicable tubing O.D.: 4 and 5/32" 17.5 (Pitch) P = 10.5 18 1.5 SS5YJ3-32,S32Stations -M5 Stations n L1 L2 10-SS5YJ3-32,S32Stations -C4 3 52 44 6 83.5
Slave unit 75 Slave unit 03 Slave unit 01 Master unit ZW-31LM SI unit Master unit SI unit Master unit SI unit SI unit SHIELD SG L2 L1 SHIELD SG L2 L1 SHIELD SG L2 L1 SG L2 L1 + + FG + + FG + + + + + + SHIELD FG FG + Twisted pair wire with shield Type 3 ground Type 3 ground Type 3 ground Type 3 ground FG FG b) 3-wire type Wiring does not include signal ground line (SG).
Allowable dynamic moment Model Mounting orientation LJ1H20 Actuator rating Load movement direction 8kg 500mm/s 600mm Work load Maximum speed Maximum stroke 600 400 L1 (mm) a = 1000 Pitching Yawing Vertical Vertical m a a = 2000 a = 3000 200 LJ1H2022PA-K (Power supply voltage 200VAC) L1 Mep 0 5 10 15 Transfer load m (kg) When an actuator is operated under conditions that exceed the lines in
Dimensions LLAA--C Stations 4-Mounting hole for W Y Dimensions (mm) A S K Model LLA2A LLA3A LLA4A LLA5A 11.5 L1 24 L2 L3 29 Sensor (Breathing port) U 2-R 34.5 (mm) H G Station 2 3 4 5 Model C Symbol P N L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 62 93 124 155 E V LLA2A 75 106 137 168 Pitch = B A (OUT) port n-Q 118 149 180 211 P (IN) port 2-Q 74 111 148 185 (Max.
U side mounting 17.5 17.5 3 1/8" PE. port 3 1/8" PE. port 38 70 38 53 Dimensions Formula: L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) Dimensions Formula: L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) n L 1 2 3 4 5 6 7 8 L1 88 113 138 163 188 213 238 263 L2 101 126 151 176 201 226 251 276 n L 1 2 3 4 5 6 7 8 L1 88 113 138 163 188 213 238 263 L2 101 126
wiring P/J/S kit for 2 to 24 stations/Single wiring L0 kit : Stations (1 to 8) L1 kit : Stations (1 to 8) L2 kit : Stations (1 to 8) !
Applicable shaft type: K (mm) X W1 L1 max L3 max (mm) Shaft type L3 = Y W2 L2 max L4 max L1 = W1 = J K T J K T J K T J K T Size Size L2 1 4.5 to 14 10 10 X 3 Y 1 0.5 to 2 0.5 to 2 6.5 to 14 L1 1 L4 = L2 = Y = L2 1 5.5 to 18 15 15 X 4 Y 1.5 0.5 to 2.5 0.5 to 2.5 8 to 18 L1 1 L2 1 6 to 20 20 20 Y 1.5 X 4.5 0.5 to 3 0.5 to 3 9 to 20 L1 1 X = L2 2 8.5 to 22 30 30 Y 2 X 5 0.5 to 4 0.5 to 4 11.5
Applicable shaft types: K, T Equal dimensions are indicated by the same marker. 20L1 = L1 = L1 L1 = Q1 = M Q1 = M Q1 = M L1 = L1 Q1 = M L1= Q1 = M K axis L1 T axis Q1 Q1 (mm) Q1 Q1 L1 L1 Size Thread M 3 x 0.5 M 4 x 0.7 M 5 x 0.8 M 6 x 1 M 8 x1.25 M10 x 1.5 Rc 1/8 Q1 (mm) 20 30 10 15 40 J axis Z axis (mm) Size Thread M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 2.5 2.5 3.3 2.5 3.3 4.2 5
wiring P/J/S kit for 2 to 24 stations/Single wiring L0 kit : Stations (1 to 8) L1 kit : Stations (1 to 8) L2 kit : Stations (1 to 8) !
Applicable bore size A1 L1 MM NDH10 NX R1 U1 Part no. Applicable bore size Dd9 d L L1 m t Included retaining ring Part no.
C4 N3 For (Built-in One-touch fitting) C4 N3 4 L2 L1 For M5 Manual override 10 12.3 35 15.5 0.2 34.2 91.7 [96.1] 78.8 [83.2] 36.5 17 12.5 P R 57.2 [59.4] P R A A A A A 31.5 56.4 [58.6] B B B B B (4.4) 2 x 4.5 (For mounting) (Pitch) P = 10.5 (Station 1) (Station n) 15.5 L1 L2 4.5 (Station 1) (Station n) (Light/surge voltage suppressor) 15.5 (Light/surge voltage suppressor) + + + + + + + +