Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: B (10mm), Stroke: 300mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: 92 [LECSN2-T
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor
Accuracy: Basic, Motor Mounting Position: R (Right Side Parallel), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: B (10mm), Stroke: 200mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: 92
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: B (10mm), Stroke: 200mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: 92 [LECSN2-T EtherNet
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: C (5mm), Stroke: 600mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: 92 [LECSN2-T EtherNet/IPâ„¢ (Absolute Encoder
Accuracy: Basic Type, Size: 40, Motor Type: T6 (100W Output, Absolute Encoder), Lead, mm: B (Size 40: 8mm, Size 63: 10mm, Size 100: 10mm), Stroke: 600mm, Motor Option: B (Lock), Cover: w/o Cover, Cable Type: S (Standard), Cable Length: 5m, Driver Type: 92 (LECSN2-T*-9, 200~240V, Absolute, EtherNet/IPâ„¢ Card), I/O Connector: H (Connector)
Accuracy: Basic Type, Size: 40, Motor Type: T6 (100W Output, Absolute Encoder), Lead, mm: B (Size 40: 8mm, Size 63: 10mm, Size 100: 10mm), Stroke: 400mm, Motor Option: B (Lock), Cover: w/o Cover, Cable Type: S (Standard), Cable Length: 5m, Driver Type: 92 (LECSN2-T*-9, 200~240V, Absolute, EtherNet/IPâ„¢ Card), I/O Connector: H (Connector)
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: C (5mm), Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: 92 [LECSN2-T EtherNet
Accuracy: Basic, Motor Mounting Position: R (Right Side Parallel), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: C (5mm), Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: L (Foot), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: 92 [LECSN2-T EtherNet/IPâ„¢ (Absolute
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Size: 40, AC Servo Motor: 400W Output, Absolute Encoder, Lead Screw: Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 550mm, Motor Option: w/Lock, Actuator Cable: Standard Cable, Actuator Cable Length: 2m, Controller: -, I/O Connector: -, Accuracy: -
Size: 40, AC Servo Motor: 400W Output, Absolute Encoder, Lead Screw: Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 550mm, Motor Option: w/Lock, Actuator Cable: Standard Cable, Actuator Cable Length: 2m, Controller: LECSS2, 200V to 230V Power Supply Voltage, I/O Connector: 1.5m, Accuracy: Basic Type
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Size: 40, Motor Mounting Position: In-line (sizes 25, 32, 40, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: B (Size 25: 6; Size 32: 8; Size 40: 10), Stroke: 550mm, Motor Option: B (with Lock), Grease Application: with, Controller Position: B (Integrated Controller), Parallel Input: 5 (NPN)
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 550mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: S (Standard Cable), Actuator
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 550mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: S (Standard Cable), Actuator