SMC Corporation of America
Elite Part Number Search
Search Results "LEY25C-300G-S3"

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket

Magnet: None, Mounting: G (Head Flange), Bore Size: 32mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)

Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 40mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: G (Head Flange)

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: G (Head Flange)

Magnet: None, Mounting: Head Flange, Bore Size: 32mm, Stroke: 300mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Rod Flange, Bore Size: 40mm, Stroke: 300mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 40mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 20mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Head Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Head Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length

EXH port P1 SUP port Sensor S1 S3 S2 S4 P2 Detection port S1, S2: Fix orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle 868 A Air Catch Sensor Series ISA2 Wiring Individual wiring Centralized wiring Terminal block 1: Brown 2: NC 3 0 1 2 3 4 Brown Blue Black DC (+) NC DC () OUT ZSE30 ISE30 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 6 9 3: Blue DC () NC DC (+) OUT 6 ZSE40 ISE40

This reduces noise considerably compared with A much lower air consumption is required than the current model. the current model. 1: Conditions: Unseated for 5 seconds and seated for 20 seconds (For G type) Comparison of detection circuit ISA3 New New Current model (ISA2) A B EXH port EXH port P1 Sensor Sensor SUP port S1 S3 SUP port S2 Sensor S1 S4 S2 Detection port P2 Detection port C D

JSY1000 series clamp bracket Wiring (JSY1000 series) JSY11M-15P-1A JSY11M-15P-2A F D-sub connector V Pm Flat ribbon cable V TC Spring type terminal block box V T Terminal block box V L Lead wire V S6 EX600 V Sm EX250 V Smm EX260 V S3 EX120 V Manifold Parts Nos.

1 t LEM e Motor type*1 r Lead [mm] q Accuracy LEY Symbol Type Output [W] Actuator size Compatible driver*2 Nil Basic type H High precision type Symbol LEJS40 LEJS63 A 16 20 B 8 10 LES S2 AC servo motor (Incremental encoder) 100 40 LECSA-S1 w Size S3 AC servo motor (Incremental encoder) 200 63 LECSA-S3 LEPY LEPS t Stroke [mm]*3 40 63 S6 AC servo motor (Absolute encoder) 100 40 LECSB-S5 LECSC-S5

Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.

Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable Without cable Without cable With cable (1.5 m) With cable (3 m) With cable (5 m) Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2