200 176.5 17 7 210.5 200 187 12 8 223 212.5 197.5 13 9 235.5 225 208 14 L1 L2 L3 L4 L1 L2 L3 L4 L n 12 260.5 250 229 16 L n 12 273 262.5 239.5 17 10 235.5 225 208 14 11 248 237.5 218.5 15 13 273 262.5 239.5 17 14 285.5 275 250 18 15 285.5 275 260.5 12.5 16 298 287.5 271 13.5 10 248 237.5 218.5 15 11 260.5 250 229 16 13 285.5 275 250 18 14 285.5 275 260.5 12.5 15 298 287.5 271 13.5 16 310.5
14 185.5 175 155.5 15 198 187.5 166 16 210.5 200 176.5 17 210.5 200 187 12 223 212.5 197.5 13 235.5 225 208 14 L n 12 13 14 15 16 11 10 L n 12 13 14 15 16 11 10 L1 L2 L3 L4 L1 L2 L3 L4 235.5 225 208 14 248 237.5 218.5 15 260.5 250 229 16 273 262.5 239.5 17 285.5 275 250 18 285.5 275 260.5 12.5 298 287.5 271 13.5 248 237.5 218.5 15 260.5 250 229 16 273 262.5 239.5 17 285.5 275 250 18 285.5
PF25 SEMI-F47 (Tough Drive )] (a)DC158V Tough DriveDC158V[AL. 10] O N OFF [Pr. PF25] (DC 158 V) ALM ( ) O N OFF WNG ( ) O N OFF MTTR ( Tough Drive ) O N OFF MBR () O N OFF O N OFF 7 24 7. (b) DC158V ON OFF [Pr. PF25] (DC 158 V) ON OFF ALM ( ) ON OFF WNG ( ) ON OFF MTTR ( Tough Drive ) MBR ON OFF () ON OFF 7 25 7. 7.4 SEMI-F47 SEMI-F47 LECSS2-TSEMI-F47 (1) [Pr.
How to Order MXW 16 100 B M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
Piston gasket N SA !II 18* Cylinder lube qaskel N SA Piston Aluminum alloy Cushion valve Steel wire Nickel plated 1 9 Snap ring Steer for spring ~40~ 1 00 ,.
M2 Find the value M2max when Va = 250 mm/s from Graph (13) c. m x g Calculate for the impact load. Since the impact is absorbed by shock absorber, the bumper coefficient = 1/100 FE = 1.4 x Va x m x g x = 1.4 x 250 x 5.5 x 9.8 x 1/100 = 188.7 [N] Dynamic moment M1 Examine M1E. Calculate the collision speed V.
(t odefReo l M ll P R I U w x (R t o , t,lt'o' 6.3t f ' tl.to.1" l2.roi, r/A 38 N/A 23 6 6.1 I t.2 0.59 Pil/PR0220ctl(s) 234 6.38 -od' o.ls f ' 12.70 iz tz.to|-, N/A 38 N/A 23 6 12 6.1 '|.2 0.77 Prr525CM(Sl 199 e.60Yl t.7o-&' r s.oo l, 25.4 lt.9-3r 5l 25 25 25 N/A 14.3 1.36 PMr55o(il(s) 250 e.60 f , r ?.
Up to 700 80 7 RS Q G 25 25 1500 250 Up to 700 80 12 32 32 1500 250 Up to 1000 80 21 RS H A 40 40 1500 250 Up to 1000 80 33 50 50 1500 250 Up to 1200 RZQ 80 47 63 63 1500 250 Up to 1200 80 84 MI W S 80 80 1500 250 Up to 1400 80 127 100 100 1500 250 Up to 1500 80 196 CEP1 Note 1)The cylinder performance may not be as expected when stroke is shorter than recommended stroke (1 to 249 stroke
D-A9 5 15 30 Note 1) 15 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 35 (n 2) (n = 2, 3, 4, 5) CM2 CM3 D-M9V 5 20 35 20 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 35 (n 2) (n = 2, 3, 4, 5) CG1 CG1 D-A9V 5 15 25 15 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 25 + 35 (n 2) (n = 2, 3, 4, 5) CG3 D-M9WV D-M9AV 10 20 35 20 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 35 (n 2) (n = 2, 3, 4, 5) JMB D-C7 D-C80 5 15
Basic Type: JB JB20, 16 Center of sphere R JB20 to 160 Center of sphere R (mm) M A Maximum operating tension and compression force (N) Maximum thread depth P Applicable bore size (mm) Model Nominal size Pitch Weight (kg) Center of sphere R Allowable eccentricity U B C D E F G H Compression Tension JB12-3-050 JB16-4-070 JB20-5-080 JB25-6-100 JB40-8-125 JB63-10-150 JB80-16-200 JB100-20-250
Floating Joint Center of sphere M M U U D H G B F P C E R A (mm) Max. operating tension and compression N Center of sphere R Model Max. screw-in depth P Allowable eccentricity U M A Applicable bore size Weight (kg) B C D E F G H Nominal size Pitch Compression Tension JB40-8-125 JB63-10-150 JB80-16-200 JB100-20-250 JB140-22-250 20, 25 32 40 50, 63 80 8 10 16 20 22 29 35.5 47.5 59 71.5 1.25
13 Power cable holder (Electric wire diameter 9 to 11) [opposite side] [mm] Dimensions Model Port size A B C D E F G H J K L M N P Q R IDF22E R1 290 775 623 134 405 698 93 46 25 13 314 85 600 340 IDF37E R1 1/2 855 680 IDF55E R2 470 855 800 128 455 868 110 36 50 13 500 75 700 526 250 519 IDF75E 900 968 13 Refrigerant R407C (HFC) Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet
n = 1 + 2 + 3 < 1 Load factors n Note Item Examine W. W max. is maximum movable load at Va. 1 =W/Wmax. (1) Max. movable load Examine Mp,My,and Mr.
[mm/s] 801900 24 to 610 16 to 410 8 to 200 9011000 24 to 500 16 to 340 8 to 170 500 10 to 500 5 to 250 20 to 1000 12 to 500 6 to 250 24 to 1200 16 to 500 8 to 250 Actuator specification 501600 20 to 900 12 to 500 6 to 250 24 to 1200 16 to 500 8 to 250 Driver type LECPA Note2) 601700 20 to 630 12 to 420 6 to 230 24 to 930 16 to 500 8 to 250 Stroke Speed range 701800 20 to 550 12 to 330 6
250, 300, 350, 400, 450, 500, 550, 600, 700, 800, 900, 1000, (1100), 1200, (1300), (1400), 1500, (1600), (1700), (1800), (1900), 2000 48 20 1000 Page 170 32 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600, (700), (800), (900), (1000) Page 170 2000 10 25 LEMH Linear guide single axis type 48 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600, (700), (800), (900), (1000),
Minimum Stroke for Auto Switch Mounting n: Number of auto switches [mm] Auto switch model Number of auto switches 32, 40, 45, 50, 56, 63, 67, 80, 85, 100 2 (Different surfaces, Same surface), 1 15 D-M9m D-M9mW n 15 + 40 (n 2) 2 (n = 2, 4, 6, 8) Note) 2 (Different surfaces, Same surface), 1 10 D-M9mV D-M9mWV n 10 + 30 (n 2) 2 (n = 2, 4, 6, 8) Note) 2 (Different surfaces, Same surface), 1
Applicable strokes: 150, 250, 350 Example) LG1H2021PA-150-F2-X2 100 5.3 8.3 400 7.7 12.0 5 to 40 (with no condensation) 200 6.1 9.6 300 6.9 10.8 mm kg kg C kg N mm/s mm Standard stroke Aluminum Stainless steel Body weight Operating temperature range Work load Rated thrust Maximum speed Performance 30 180 500 0.02 AC servomotor (100W) Incremental system Ground ball screw 15mm, 10mm lead High
Note 6) When N is specified in the end of part number of auto-drain, applicable tubing O.D should be 3/8". 14-2-22 23 F.R.L. Unit Series AC20D to 40D Dimensions AC20D A F N E P K C G G IN OUT Q F.R.L.
L1=(14 x n)+36 10 16 14 10 14 Y W Pressure gauge (Accessory) V X 2 x 4.3 L3=50+R+V L4=50+T+X H H L L S S O O M4 thread hole U U C C P P K K 50 SMC 25 S T R L2=(14 x n)+29 29 55 (Max. 58) Note) U IN IN IN 33 15 14 Note) Max. dimension is the size when the knob is unlocked.