to +60C, -10C to +70C without magnet Piston speed [mm/s] 50 1000 [mm] Standard strokes Standard stroke Max.
Under conditions of inlet air pressure: 0.7MPa, inlet air temperature: 35C, ambient temperature: 32C, outlet air pressure dew point:10C. Note2)
Specifications Bore size (mm) Action Fluid Proof pressure 6 8 10 D-F8N/F8B Double acting 6 1 Air 1.05MPa 0.15MPa 0.1MPa Minimum operating pressure Double acting Maximum operating pressure 0.7MPa Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C (No freezing) Ambient and fluid temperature Note) The above values should be used as a guide for detection at stroke end.
Symbol -XB6 Heat Resistant Cylinder (10 to 150C) 3 Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 150 from 10C.
Inlet air temperature 35C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.5MPa Air flow 1200 l/min (ANR) Inlet air temperature 55C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.7MPa Air flow 350 l/min (ANR) Condition Condition A = 0.75 based on conditions q, w and e 1 1 B = 0.95 based on conditions q, w and e C = 1.00 based on
A cylinder in which the material of the seals has been changed to a heat resistant style (for up to 110C) so that it can be operated under extreme ambient temperatures that exceed the standard specifications of between -10C and +70C. Mounting MB MBK XC8 Bore size Stroke Add'l symbol Stroke adjustment symbol Standard model no.
Serial communication USB2.0 (Full Speed 12 Mbps) Memory Flash-ROM LED indicator PWR, RUN, USB, ALM, NS, MS, L/A, 100 Lock control Forced-lock release terminal *4 Communication Cable length Actuator cable: 20 m or less Cooling system Natural air cooling Operating temperature range 0C to 40C (No freezing) Operating humidity range 90% RH or less (No condensation) Storage temperature range 10C
Serial communication USB2.0 (Full Speed 12 Mbps) Memory Flash-ROM LED indicator PWR, RUN, USB, ALM, NS, MS, L/A, 100 Lock control Forced-lock release terminal *4 Communication Cable length Actuator cable: 20 m or less Cooling system Natural air cooling Operating temperature range 0C to 40C (No freezing) Operating humidity range 90% RH or less (No condensation) Storage temperature range 10C
OFF *1 10C 3 Check the effect of ambient temperature. Please review the setting value. There may be causes such as large load fluctuation and flow rate fluctuation. Please review the setting value. AL12 CH1 TEMP READY ALARM OFF *1 +1/-1C 3 CH2 High Temp.
Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C (No freezing) Rubber bumper, Air cushion Not required (Non-lube) JIS 2nd class Ambient and fluid temperature Cushion Lubrication Thread tolerance Stroke tolerance CL Non-locking and locking styles are standard for manual release. +1.4 0 MLGC Rubber bumper Air cushion 50 to 750mm/s 50 to 1000mm/s Piston speed CNA Basic
Inlet air temperature 35C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.5MPa Air flow 1200 l/min (ANR) Inlet air temperature 55C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.7MPa Air flow 350 l/min (ANR) Condition Condition A = 0.75 based on conditions q, w and e 1 B = 0.95 based on conditions q, w and e 1 C = 1.00 based on
Effective value N Action Internal gripping force External gripping force 4 55 9.8 10 MHZ2-10D (N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C
Furthermore, when controlling for low speed or controlled output, use clean air (atmospheric pressure dew point temperature of 10C). Installation of a mist separator (filtration degree 0.3m or less) is also recommended. 3. Use a metal seal type when using solenoid valves for cylinder actuation.
Series SV3000,SV4000 DIN rail holding screw tightening torque: 1.4Nm Supply/Exhaust block assembly Circular connector (type 10C) EX250 (type 10S1W) D-sub connector (type 10F) , , and are not included with the supply/exhaust block assembly. Included only with the DIN rail mount type.
Bore Size: 10mm, Stroke: 20mm, Adjuster: C (Metal Stopper), Magnet: Magnet and Rail, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 10mm, Stroke: 10mm, Adjuster: Rubber Stopper, Magnet: Magnet and Rail, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 10mm, Stroke: 20mm, Adjuster: Rubber Stopper, Magnet: Magnet and Rail, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 10mm, Stroke: 20mm, Adjuster: Metal Stopper, Magnet: Magnet and Rail, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 10mm, Stroke: 10mm, Adjuster: Rubber Stopper, Magnet: Magnet and Rail, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 10mm, Stroke: 20mm, Adjuster: Rubber Stopper, Magnet: Magnet and Rail, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)