SMC Corporation of America
Elite Part Number Search
Search Results "MXP16-20C-M9BWL"

Features 1 New New 5 port solenoid valve series SY9000 Cv 2.8 (base mounted type with sub-plate) Interface regulator series ARBY3000/5000 (for series SY3000/5000) High speed response: 10ms (SY3000 single solenoid, 0.5MPa, 20C) (representative value) The innovative design of the pilot valve makes it possible to achieve a short response time of 10ms while consuming only a half watt of power

Standard Specifications/Single Unit (Standard Dew Point 20C) Membrane Air Dryer Series IDG Model Standard dew point: 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters. -20C low dew point just by installing in air pressure line.

The value of the minimum bending radius is measured at the temperature of 20C as shown below. KP LQ MQR Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. T T Fixed end IDK 3.

Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter change rate of 10% or less.

(mm) 7.3 5.8 4.4 2.8 8.8 Black (B) White (W) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Blue (BU) Fixed end Translucent (N) Fluid Air 20C 0.8 Max.

Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less.

Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.

Note 2) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20C, 101.3 kPa, and 65% RH. Note 3) Without lead wire. Note 4) Accumulated flow rate is reset when the power supply turns OFF. Note 5) Switch output and accumulated pulse output can be selected during initial setting.

Flow at 20C, atmospheric pressure, and 65% of the relative humidity The maximum flow capacity varies depending on the inlet pressure.

(Coil temperature : 20C, at rated voltage and without surge voltage suppressor) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

Item Property Conductor resistance /km, 20C 65 or less Voltage limit V, 1 minute, AC 1000 Circular connector cable assembly Insulation resistance M/km, 20C Note) When using the negative COM specification, use valves for negative COM. 5 or more Assembly part no.

Lead wire length 0 1 2 0.6 m 1.5 m 3.0 m Electrical characteristics Item Characteristic Sheath Colour: Urban white Conductor resistance /km, 20C 65 or less Withstand pressure V, 1 minute, AC 1000 Polarity Terminal no. Lead wire colour Dot marking Insulation resistance M/km, 20C 5 or more 1 () (+) Black None SOL. A 14 () (+) Yellow Black Station 1 SOL.

Insulation resistance M/km, 20C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 or more Note) The minimum bending radius of the D-sub connector cables is 20 mm.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

Note) Supply pressure: 0.5MPa, Temperature: 20C. In-line style How to Order 1F 12 K 400 AS JIS Symbol Option Body size K N None Hexagonal lock nut Electroless nickel plated 100 200 205 300 400 M5 1/8 1/4 3/8 1/2 Indicate symbols in alphabetical order if two options or more desired. Applicable tube O.D.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Compact design with large flow Sonic conductance: C [dm3/(sbar)] Body width [mm] 10 15 18 1.1 2.8 4.5 Response time 10 ms (Representative value) (SX3000 double, 0.5 MPa, 20C) High reliability and long service life exceeding 50 million cycles or more (

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 4) For VFR600-FZ-06, ( ): VFR610-DZ-06 3-5-93 94 Series VFR6000 How to Order Option Electrical entry Nil Z None With light/surge voltage suppressor F: Plug-in type, conduit type Not applicable to grommet terminal.

Black White 24 5 or less Insulation resistance, M/km, 20C White None 25 Note) The minimum inside bending radius for each cable is 20mm.