Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: G + J
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: M + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: J + M
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: G + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Fixed SI Unit
2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop output, BCD outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CNPN open collector Max 30 VDC, 50 mA ?390 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.
2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop output, BCD outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CNPN open collector Max 30 VDC, 50 mA ?321.6 to 26.4 VDC10 W or lessBetween case and AC line: 1500 VAC for 1 min.
2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CNPN open collector Max 30 VDC, 50 mA90 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.
2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop output, BCD outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CPNP open collector Max 30 VDC, 50 mA ?390 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.
2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CPNP open collector Max 30 VDC, 50 mA21.6 to 26.4 VDC10 W or lessBetween case and AC line: 1500 VAC for 1 min.
2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CPNP open collector Max 30 VDC, 50 mA90 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.
NCA1F200-2100-XA22, TIE ROD CYLINDER, 3.75 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, 2100 lb