SMC Corporation of America
Elite Part Number Search
Search Results "NCDQ8BZ300-400C-M9N"

Magnet: Built-in, Mounting: Through Hole, Overall Length: Super Compact, Bore Size: 3", Stroke: 1 1/2", Body Option: Standard (Rod End Female Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Through Hole, Overall Length: Super Compact, Bore Size: 3", Stroke: 1/2", Body Option: Standard (Rod End Female Thread), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Through Hole, Overall Length: Super Compact, Bore Size: 3", Stroke: 1 1/2", Body Option: Standard (Rod End Female Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Through Hole, Overall Length: Super Compact, Bore Size: 3", Stroke: 1", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: None, Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection

Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Z (Super Compact), Bore Size: 300 (3"), Stroke: 200 (2"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m)

SMC's new NCQ8 series is a square body, compact cylinder that allows close center to center mounting. Visibility of auto switch is improved over the NCQ7 series and is mountable on multi-sides. Use of the retaining ring method improves maintenance performance. Replacing seals is easily obtained by removing the collar. Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT, ACTUATOR, NCQ8 COMPACT CYLINDER, QE, 3 NCQ8 DBL-ACT AUTO-SW, .00000 lb

SMC's new NCQ8 series is a square body, compact cylinder that allows close center to center mounting. Visibility of auto switch is improved over the NCQ7 series and is mountable on multi-sides. Use of the retaining ring method improves maintenance performance. Replacing seals is easily obtained by removing the collar. Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT, ACTUATOR, NCQ8 COMPACT CYLINDER, QE, 3 NCQ8 DBL-ACT AUTO-SW, .00000 lb

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 80mm, Stroke: 400mm, Cushion: C (Air Cushion and Rubber Bumper)

CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm.  High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life.  Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod.  Standard strokes range from 25 to 800mm.Double Acting

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 40mm, Stroke: 400mm, Cushion: C (Air Cushion and Rubber Bumper)

Size: 40, Motor Mounting Position: Top Mounting, Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: C (w/Motor Cover)

Magnet: None, Mounting: L (Axial Foot), Bore Size: 40mm, Stroke: 400mm, Cushion: C (Air Cushion and Rubber Bumper)

Size: 25, Motor Mounting Position: Top Mounting, Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: C (w/Motor Cover)

Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 50, Stroke: L(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead