SMC Corporation of America
Elite Part Number Search
Search Results "NCGFN20-0100-XB7"

Double acting, single rod cylinder; High temperature (XB6) Bore sizes (mm) 6, 10, 16; Low temperature (XB7) Bore sizes (mm) 6, 10, 16; Low temperature (XB7) ambient range -40 to 70°C; High temperature (XB6) ambient range -10 to 150°C

Double acting, single rod cylinder; High temperature (XB6) Bore sizes (mm) 6, 10, 16; Low temperature (XB7) Bore sizes (mm) 6, 10, 16; Low temperature (XB7) ambient range -40 to 70°C; High temperature (XB6) ambient range -10 to 150°C

Double acting, single rod cylinder ; High temperature (XB6) Bore sizes (mm) 20, 25, 32, 40 ; Low temperature (XB7) Bore sizes (mm) 20, 25, 32, 40 ; Low temperature (XB7) ambient range -40 to 70°C ; High temperature (XB6) ambient range -10 to 150°C

Double acting, single rod cylinder; High temperature (XB6) Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, 80, 100; Low temperature (XB7) Bore sizes (mm): 12, 16, 20, 25, 32, 40; Standard stroke range (mm): 5 to 100; Port threads: M (12 to 25 bore); Rc, NPT or G (32 to 100 bore); Low temperature Option (XB7) ambient range -40 to 70°C; High temperature Option (XB6) ambient range -10 to 150

The XB7 low temperature resistant option is rated for use in environments down to -22° F (-30° C) XB6 high temp & XB7 low temp resistant options; Double acting single rod; Bore sizes: 1½, 2, 2½, 3¼, 4"; Strokes from 1 to 30"; 12 mounting options

Double acting single rod ; XB6 and XB7 bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 ; XB14 bore sizes (mm): 16, 20, 25, 32, 40, 50, 63 ; Mounting include: Through hole (standard), threaded, clevis, foot, head flange, and rod flange ; Low temperature option (XB7) temperature range -40°F to 158°F ; High temperature option (XB6) temperature range 10°F to 302°F ; Heat resistant auto

Double acting, single rod cylinder ; High temperature (XB6) Bore sizes (mm): 20, 25, 32, 40, 50, 63 ; Low temperature (XB7) Bore sizes (mm): 20, 25, 32, 40, 50, 63 ; Low temperature (XB7) ambient range -40 to 70°C ; High temperature (XB6) ambient range -10 to 150°C

XB6 High temperature resistant cylinder XB7 Low lemperature resistant cylinder xBg Low speed cylinder Modification ol rod end %srrc I SERIES NCJ2 Standard Type: Double Acting/Single Rod Series NCJ2 Bore Size s6, a1O, s16 Special options ffi Hrgh tmpetature tvpe mTowlempeEiure itpe Tow speed ope'rat-bn NC iDI J2 .-T se page 16 lor specilicalions of special options.

Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.

[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.

Magnet: None, Mounting: F (Front Flange), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke: 0200 (2")

Magnet: None, Mounting: F (Front Flange), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke: 0150 (1 1/2")

Magnet: None, Mounting: F (Front Flange), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke: 0600 (6")

Magnet: None, Mounting: F (Front Flange), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke: 0300 (3")