Magnet: None, Mounting: B (Standard, Through-hole), Bore Size: 25mm, Stroke 1: 10mm, +: None, Stroke 2: 40mm, Body Option: C (w/Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke Cylinder, Double Rod Type)

Magnet: None, Mounting: B (Standard, Through-hole), Bore Size: 25mm, Stroke 1: 25mm, +: None, Stroke 2: 25mm, Body Option: C (w/Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke Cylinder, Double Rod Type)

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 25mm, Stroke 1: 10mm, +: None, Stroke 2: 40mm, Body Option: w/Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke Cylinder, Double Rod Type

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 25mm, Stroke 1: 20mm, +: None, Stroke 2: 20mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 25mm, Stroke 1: 20mm, +: None, Stroke 2: 20mm, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 25mm, Stroke 1: 25mm, +: None, Stroke 2: 20mm, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 25mm, Stroke 1: 25mm, +: None, Stroke 2: 25mm, Body Option: w/Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke Cylinder, Double Rod Type

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 25mm, Stroke 1: 25mm, +: None, Stroke 2: 25mm, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 25mm, Stroke 1: 40mm, +: None, Stroke 2: 40mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

lBore size slainlss steel D slon rod Adjustable stroke Exrend'" -xc9 Adjustable slrokeRelracl^^ -xc10 Dul slfokeDouble rod" 25 25frfr i9)nuto switcrr See cata og E2161or ava ab e auto swlclres -xcl2 Aulo swilch rai mounlinq 63 63mn a0 1 m -xc36 -xc37 -xc42 (Ocytinaer strote (mm) "see calalog E21 6 for 'How 1o order' nformal on r o ' Not ava ab e lor boe s 4 o80 Norel S nq e acrng.6labe 20

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches

Bore sizes in mm: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100, Strokes from 5mm to 100mm depending upon bore size, Mounts: through hole, both ends tapped, foot, front & rear flange, double clevis, rear boss, Variety of switches and a variety of lead wire lengths, "Compact Cylinder, NCQ2, COMPACT CYLINDER, N lb

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 25mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Resistant: XB6 [Heat Resistant (-10 to 150°C)]