Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m), Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
How to order: EX500-AP 050 S How to order: EX500-AC 030 SSPS How to order: EX500-AC000-S 1 How to order: EX9-AC 010 1 How to order: EX9-AP 010 7 Cable length (L) Connector specification 003 0.3 [m] 005 0.5 [m] 010 1 [m] 030 3 [m] 050 5 [m] Cable length (L) Connector specification 010 1 [m] 050 5 [m] Cable length (L) 010 1 [m] 030 3 [m] 050 5 [m] Cable length(L) 010 030 1[m] 3[m] S Straight
M2 W1 CC W3 : Collision speed (mm/s) L1 : Distance to the center of load gravity (m) ME : Dynamic moment (Nm) g : Gravitational acceleration (9.8 m/s2) YES m : Load weight (kg) F : Load (N) FE : Load equivalent to impact (at impact with stopper) (N) a : Average speed (mm/s) Pitch moment Yaw moment NO M1 = W4 x L3 M2 = W1 x L2 RB M1e = We x L3 x 1 3 M3e = We x L2 x 1 3 NO Do not use it
Cable length (L) A1 (17.7) (10.2) 1 2 5 6 (14) (18) 1 3 5 8 A B C 1.5 m 3 m 5 m 8 m A6 B1 B3 A1 A3 B6 (13.5) 1 2 5.7 15 16 Connector B Connector D (30.7) L (11) (14.7) (10) 10 m LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) 8 A B C 15 m Actuator side Controller side 20 m 5.5 6.3 5.7 (14.2) Connector C (Terminal no.)
Ordering example) Lead wire length 5A 10 ZS ZCU Lead wire length (For DC) Nil 6 10 15 20 25 30 0.3 m (Standard) 4A 20 VJ10 6 AMJ 0.6 m 1 m 1.5 m 2 m 2.5 m 3 m Note) If ordering a vacuum switch with 3 m lead wire, specify both the vacuum unit switch and the 3 m lead wire connector part numbers. Nil 30 50 0.6 m 3 m 5 m (For 100 VAC) 1A 36 VJ10 6 Misc. ZX1051-K15LOZ-EC 1 pc.