SMC Corporation of America
Elite Part Number Search
Search Results "PSE564-A2-28-C2"

Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal

Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal

No.ZB-OM00301 / ZB No.ZB-OM00301 2 9 12 13 15 16 16 V Assy 17 21 25 26 28 28 29 30 30 31 31 32 35 37 38 39 40 Assy 40 Assy 41 42 1 - No.ZB-OM00301 1) (ISO/IEC) (JIS) 2 *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.

Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2+...1/Cn) when in series, and C=C1+C2+...Cn, when in parallel.

Proper tightening torque (Nm) Tightening Torque for Piping Connection thread 7 to 9 12 to 14 22 to 24 28 to 30 Rc Rc Rc Rc 1 8 1 4 3 8 1 2 5. Piping to products When piping to a product, refer to the operation manual to avoid mistakes regarding the supply port, etc. Back page 5 5 Port Solenoid Valves Precautions 4 Be sure to read this before handling.

Solenoid valve No. 3 8 7 6 5 4 3 2 1 2 No. 8 No. 7 8 7 27 (For C2: 28) 9 No. 6 No. 5 No. 4 No. 3 No. 2 No. 1 6 5 33.6 (Pitch) P = 6 (2) 38 4 3 2 1 1 (No.1) Groove side Barb fitting [1(P), 2(A), 3(R) port] Applicable tubing O.D. 4, I.D. 2.5, Polyurethane tubing (made by SMC) Soft nylon tubing (made by SMC) Connector (L = 300 to 1000) Lead wire length Cut dimension for panel mount (mounting

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Note 4) Energization on A (set) side generates vacuum and energization on B (reset) side stops generation of vacuum. 28 - Doc. no. ZB-OM00201-B How to operate the supply valve of the latching type Latching type refers to a solenoid with a self holding mechanism.

Note) Except SI Unit 604 5 Port Solenoid Valve EX260 (Output device for driving 5 port solenoid valves) Compatible Protocols Compact 28 mm SV SYJ SZ Number of outputs Each 32/16 digital output type available in the series VF Output polarity Each negative common (PNP)/positive common (NPN) type available in the series VP4 Enclosure IP67 (For Units with D-sub connector, and when connected

[mm] Bore size A B C D F GA H MM NA NDh8 NN S T Z 6 15 12 14 3 8 14.5 28 M3 x 0.5 16 6 0 0.018 M6 x 1.0 61 (66) 3 117 (122) 10 15 12 14 4 8 8 28 M4 x 0.7 12.5 8 0 0.022 M8 x 1.0 49 105 16 15 18.3 20 5 8 8 28 M5 x 0.8 12.5 10 0 0.022 M10 x 1.0 50 106 : ( ) in S and Z dimensions: With auto switch With Air Cushion/Dimensions other than the table below are the same as the table above.

VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5

N x P (52) 28 20 U N (M6 x 1) C (5.1) 1 0.2 5 T-slot A 36: T-slot pitch 39 36 28 Body mounting reference plane 4H9 +0.030 0 6.5 27.5 Work piece mounting reference plane Refer to Cross section C-C.

ZS-28-CA-2 ZS-28-CA-2 ZS-28-CA-3 ZS-28-CA-2 ZS-28-CA-3 ZS-28-CA-3 ZS-28-CA-3 ZS-28-CA-3 ZS-28-CA-3 ZS-28-CA-3 ZS-28-CA-3 ZS-28-CA-3 ZS-28-CA-4 ZS-28-CA-4 ZS-28-CA-4 SMC part no. Manufacturer's part no.

N x P (52) 28 20 U N (M6 x 1) C (5.1) 1 0.2 5 T-slot A 36: T-slot pitch 39 36 28 Body mounting reference plane 4H9 +0.030 0 6.5 27.5 Work piece mounting reference plane Refer to Cross section C-C.

(mm) Bore size A B C D F GA GB H MM NA NB NDh8 NN S Z 10 15 12 14 4 8 8 5 28 M4 x 0.7 12.5 9.5 8 0 0.022 M8 x 1.0 46 74 16 15 18.3 20 5 8 8 5 28 M5 x 0.8 12.5 9.5 10 0 0.022 M10 x 1.0 47 75 Single foot (L) CJ2YL Bore size Stroke Head cover port location Z Mounting nut Rod end nut Piping port 2 x M5 x 0.8 GB NN F GA Cover surface MM C D 0 0.3 LY LB B LH 0 0.3 B LX LT Piping port M5 x 0.8

D C B E1 L1 MM H A A1 R1 U1 d NDH10 NX 40 50, 63 80 100 I-04 I-05 I-08 I-10 NT-04 NT-05 NT-08 NT-10 21 25.4 22 8 69 22 24 55 M14 X 1.5 15.5 20 M14 X 1.5 12 16 +0.070 0 0.1 0.3 26 31.2 27 11 74 27 28 60 M18 X 1.5 15.5 20 M18 X 1.5 12 16 +0.070 0 0.1 0.3 31 37.0 32 13 91 37 36 71 M22 X 1.5 22.5 26 M22 X 1.5 18 28 +0.070 0 0.1 0.3 39 47.3 41 16 37 40 83 M26 X 1.5 24.5 28 M26 X 1.5 105 20 30

L NZ RR1 NX E1 L1 MM U1 ND A1 Cotter pin Polishing ball 12 Y-04C 40 +0.3 +0.1 16 38 M14 X 1.5 12 3 X 18l 22 24 55 13 25 55.5 Polishing ball 12 Y-05C 50, 63 +0.3 +0.1 16 38 M18 X 1.5 12 3 X 18l 27 28 60 15 27 55.5 Polishing ball 18 Y-08C 80 +0.3 +0.1 28 55 M22 X 1.5 18 4 X 25l 37 36 71 19 28 76.5 Polishing ball 20 Y-10C 100 +0.3 +0.1 30 61 M26 X 1.5 20 4 X 30l 37 40 83 21 38 83 Knuckle pins

Table 3-10 Piping port size Description Port Recommended Recommended piping size tightening torque specifications Circulating fluid outlet port Rc1/2 28 to 30Nm 0.4MPa or more*2 Circulating fluid return port Rc1/2 28 to 30Nm 0.4MPa or more*2 Facility water inlet port *3 Rc3/8 22 to 24Nm 1.0MPa or more (Supply puressure: 0.3 to 0.5MPa) Facility water outlet port *3 Rc3/8 22 to 24Nm 1 For NPT