42 35.5 13 30 80 346 M24 x 1.5 35 32 28 11 24 70 326 0.030 0.076 0.036 0.090 80 65 55 M39 x 1.5 60 57 45 15 41 95 392 M30 x 1.5 45 42 35.5 13 30 80 362 0.030 0.076 100 80 65 M48 x 1.5 75 72 56 16 50 115 442 M39 x 1.5 60 57 45 15 41 100 412 393
Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.
25 150 Up to 700 25 45 MK(2) 1500 32 150 Up to 1000 32 50 RS Q G 40 200 Up to 1000 40 60 Note 1) The cylinder performance may not as expected when stroke is shorter than recommended stroke even they are available.
Basic mass 0.90 (Foot style 32) Additional mass 0.09/50 st Cylinder stroke 200 (st) 0.90 + 0.09 x 200/50 = 1.26 kg CX MQ RHC Mounting Bracket Part No.
Basic mass 0.90 (Foot style 32) Additional mass 0.09/50 st Cylinder stroke 200 (st) 0.90 + 0.09 x 200/50 = 1.26 kg CX MQ RHC Mounting Bracket Part No.
0.55 45 0.58 45 1.08 45 1.18 AF3000 Bowl capacity (cm 3) Weight (kg) VEX Accessory (Standard) Bowl guard AW Accessory (optional) Part No.
1 2 3 4 5 6 7 8 9 10 11 12 13 80 0 5 10 15 20 25 30 35 40 45 50 55 60 Load capacity (N) Load capacity (pounds) 63 300 12.0 280 11.0 Distance from pivot point (inches) 260 Distance from pivot point (mm) 10.0 240 9.0 220 200 8.0 180 7.0 160 6.0 140 5.0 120 100 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 4.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Load capacity (N) Load capacity
Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.
flow rate L/min 120 16 130 16 180 16 Maximum pump head m 50 49 55 49 68 49 Settable pressure range*5 MPa 0.10 to 0.50 0.10 to 0.49 0.10 to 0.55 0.10 to 0.49 0.10 to 0.68 0.10 to 0.49 Minimum operating flow rate*6 L/min 20 2 25 2 40 2 Tank capacity L 42 7 42 7 60 7 Bypass circuit (With valve) Installed Electric conductivity setting range S/cm 0.5 to 45*9 0.5 to 45 0.5 to 45*9 0.5 to 45 0.5
LB LC LD LE LF LH LT Model LA F H MM U FD FT FX FY ZX ZY Model M 6 x 1.0 depth 12 200 (233) 224 (257) CRA1L50 CRA1F50 41 62 9 4 39 44 108 4.5 114 9 13 90 50 110 81 M 6 x 1.0 depth 12 235 (273.5) 263 (301.5) CRA1L63 CRA1F63 48 76 11 5 45 55 127 5 136 11.5 15 105 59 130 101 M8 x 1.25 depth 16 274 (318) 316 (360) CRA1L80 CRA1F80 58 92 13 5 55 67 154 6 165 13.5 18 130 76 160 119 M10 x 1.5 depth
LB LC LD LE LF LH LT Model LA MM U FD FT FX FY ZX ZY F H Model M 6 x 1.0 depth 12 200 (233) 224 (257) CRA1L50 CRA1F50 41 62 9 44 4 39 108 4.5 114 9 13 90 50 110 81 M 6 x 1.0 depth 12 235 (273.5) 263 (301.5) CRA1L63 CRA1F63 48 76 11 55 5 45 127 5 136 11.5 15 105 59 130 101 M8 x 1.25 depth 16 274 (318) 316 (360) CRA1L80 CRA1F80 58 92 13 67 5 55 154 6 165 13.5 18 130 76 160 119 M10 x 1.5 depth
Port size For sub-plate, manifold type 40, 41, 42, 43 Nil: Without sub-plate R port P, E port 3: Common exhaust type for main and pilot valve D: Push-turn locking slotted type R port P, E port (With gasket and screws) Electrical entry 01: 1/8 With sub-plate 24, 12, 6, 5, 3 VDC M8 connector 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC 24,12 VDC 100,110, 200, 220 VAC Grommet L plug connector M
Applicable pad 04U/06U/08U Applicable pad 10U/16U Applicable pad 25U/32U Applicable pad 40U/50U 4.9 30 R 30 R R 25 30 R R R R 10.5 9.5 2 8 9 25 R 2 0.5 6 7 7 8 R R R R R R 45 45 45 2.7 1 R R 2.5 4.5 5 6.6 R 2.5 3.8 4.9 3.5 5 6 7.9 R 4.5 8 9 11.7 11.7 Note) R part has to be smooth with no corners.
Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.
Bore size CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] Series 40 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQ4100--03 VQ4101--03 1100 1000 900 800 700 600 500 400 300 200 100 0 VQ5100--04 VQ5101--04 Values at extension
, 30, 35, 40, 45, 50, 60, 70, 75, 80, 90, 100 110 to 200 Refer to Made to Order Specifications for stroke which exceeds the standard stroke length.
300 0 100 200 300 100 200 300 Load (N) Load (N) Load (N) 25 25 25 Lr = 200 mm 0.08 MXQ25-150 MXQ25-150 MXQ25-150 MXQ25-10 MXQ25-10 MXQ25-20 MXQ25-20 MXQ25-30 MXQ25-30 MXQ25-40 MXQ25-40 MXQ25-100 MXQ25-125 MXQ25-150 MXQ25-50 MXQ25-75 MXQ25-10 MXQ25-20 MXQ25-30 MXQ25-40 MXQ25-50 MXQ25-50 MXQ25-75 MXQ25-75 0.12 0.10 MXQ25-75 MXQ25-75 MXQ25-75 MXQ25-40 MXQ25-40 MXQ25-40 Table displacement amount
Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.
100/400 100/200 100/200 100/200 100/200 100/200 100/200 100/200 100/200 50/100 * Dimension A reference after installation. 45 Female Elbow KV2KF_ _-_ _ D2 D1 L1 M Applicable Tube L3 L2 H Thread D4 D3 App.
400 300 200 100 0 VF B VFR VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VZS C VFS VS4 800 700 600 500 400 300 200 100 0 VQ7 D EVS VFN 800 700 600 500 400 300 200 100 0 E It is when the cylinder is extending that is meter-out