IDG50HV IDG60HV IDG75HV IDG100HV 25 50 100 200 300 500 600 750 1000 25 50 100 200 300 500 600 750 1000 IDG30LV IDG50LV IDG60LV IDG75LV IDG100LV 75 110 170 240 300 IDG60SV IDG75SV IDG100SV 50 100 150 Note) Standard dew point : Outlet air atmospheric pressure dew point under standard performance conditions Standard purge rate : Ratio of purge air flow rate to inlet air flow rate under standard
HRS HRS 090 HRS 090 HRS 100/150 Protection Circuit Item Unit Standard value Influence HRSH 090 Corrosion Scale generation Caution pH (at 25C) 6.5 to 8.2 v v Electric conductivity (25C) [S/cm] 100* to 800* v v Chloride ion (Cl) [mg/L] 200 or less v Sulfuric acid ion (SO42) [mg/L] 200 or less v HRSH If operating in the below conditions, the protection circuit will activate and an operation
, 200, 300 500 10 150, 200, 300, 400, 500 750 15 1 axis 200, 300, 400, 500, 600 1000 20 200, 300, 400, 500, 600, 800 25 1200 25 2 axes 200, 300, 400, 500, 600, 800, 1000 1500 32 Note 1) Strokes exceeding the standard strokes are available as a special order.
port 1/8 IN port 1/2 221 62 62.8 8 OUT port 1/2 Silencer (Option) 22 32 EXH port 1/2 96 4 x 12 130 3.2 116 150 (When silencer installed: 200) (When high-noise reduction silencer installed: 230) For detailed dimensions, specifications and lead times, please contact SMC.
Model XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 Rated voltage for heater 90 to 240 VAC Heater assembly quantity 1 1 1 1 H4 100C 100 V 200/40 200/50 400/100 600/150 Heater assembly quantity used Heater power W (Nominal value) Inrush/Power consumption (Option symbol, Operating voltage) 200 V 800/40 800/50 1600/100 2400/150 Heater assembly quantity 1 1 1 1 2 H5 120C 100 V 200/40 400/70 400/
300 400 500 600 700 800 900 1000 Flow rate (slpm, N2) 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Flow rate (slpm, N2) AK1200HF 150 psig (1.0 MPa) 50 psig (0.34 MPa) Inlet pressure: 100 psig (0.69 MPa) AK1200FC Inlet pressure: 150 psig (1.0 MPa) 3/4 inch connections ) 100 0.69 75 0.52 0.62 90 0.55 80 60 0.41 Delivery pressure (MPa) Delivery pressure (MPa) Delivery pressure (
CXS15 CXS20 CXS25 CXS32 Model 120 150 200 175 150 125 120 110 200 175 150 125 120 110 200 175 150 125 120 110 125 120 110 150 125 110 100 90 80 Stroke SS ZZ Z 175 210 282 257 232 207 202 192 272 247 222 197 192 182 270 245 220 195 190 180 185 180 170 205 180 165 155 145 135 Symbol Made to Order 192 229 312 287 262 237 232 222 296 271 246 221 216 206 294 269 244 219 214 204 204 199 189 222
200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure 0.5MPa ARM11AA1-312 (One-touch fittings: IN 10, OUT 6) ARM11AA1-312-1 (One-touch fittings: IN 10, OUT 6) 0.6 0.7 0.30 0.35 Outlet pressure MPa Outlet pressure MPa 0.25 0.5 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 250 300 0 50 100 150 200 Flow
, 200, 250, 300 10 RHC 150, 200, 250, 300, 350, 400, 450, 500 15 750 MK(2) 20 1000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 Made to Order Specifications (For details, refer to page 10-21-1.)
, 200, 250, 300 10 RHC 150, 200, 250, 300, 350, 400, 450, 500 15 750 MK(2) 20 1000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 Made to Order Specifications (For details, refer to page 10-21-1.)
Formula: L1 = 10.5n + 45, L2 = 10.5n + 93.5 n: Stations (Maximum 16 stations) n L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 L2 L3 L4 55.5 66 76.5 87 97.5 108 118.5 129 139.5 150 160.5 171 181.5 192 202.5 213 104 114.5 125 135.5 146 156.5 167 177.5 188 198.5 209 219.5 230 240.5 251 261.5 125 137.5 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5 275 287.5 135.5 148 160.5 173 185.5
Switch (When equipped with switch) Internal Pilot Manifold L Dimension n: Stations External Pilot Manifold L Dimension n: Stations L n 4 173 162.5 145 14 L n 4 185.5 175 155.5 15 2 148 137.5 124 12 3 160.5 150 134.5 13 5 185.5 175 155.5 15 6 198 187.5 166 16 7 210.5 200 176.5 17 8 210.5 200 187 12 9 223 212.5 197.5 13 2 160.5 150 134.5 13 3 173 162.5 145 14 5 198 187.5 166 16 6 210.5 200
, 200 M6 x 1 depth 9 45 25 80 60 55 30 108 25 M6 115 65 125 112 11 12 9 6.6 95 82 99 M6 x 1 depth 13 54 35 100 70 65 35 130 30 M8 135 75 150 134 13 16 9 9 108 92 109 75, 100 125, 150 200, 250 300 M6 x 1 depth 13 60 35 106 80 73 40 135 35 M8 140 85 150 134 16 16 9 9 118 102 129 75 50 134 95 93 50 170 45 M8 175 105 186 170 19 19 M8 x 1.25 depth 16 12 9 150 134 152 90 56 152 115 103 55 194 50
l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150 501 to 600 175 175 601 to 700 187.5 187.5 701 to 750 73 81 89 89 101 101 1 to 50 86 94 102 102 114 114 51 to 100 98 106 114 114 126 126 101 to 150 111 119 127 127
, 175, 200, 250, 300, 350 W 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 Minimum Auto Switch Mounting Stroke Manufacture of Intermediate Strokes (mm) Spacers installed Spacers are installed in standard stroke cylinders. 20 to 32: Stroke can be modified in 1mm increments. 40 to 100: Stroke can be modified in 5mm increments.
, 175, 200, 250, 300, 350 W 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 Minimum Auto Switch Mounting Stroke Manufacture of Intermediate Strokes (mm) Spacers installed Spacers are installed in standard stroke cylinders. 20 to 32: Stroke can be modified in 1mm increments. 40 to 100: Stroke can be modified in 5mm increments.
Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option) CH1 0.1 15 to 25 HRL Inverter dual type 26 kW Indoor use 19 kW 9 kW CH2 0.5 20 to 40 1.0 kW (Max. 1.5 kW) 322 Circulating Fluid
Standard type 1.0 5 to 35 V V HRSH090 Inverter type 0.1 5 to 40 V Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (400 V as standard, 200 V as an option) (Only 200 V as an option) Indoor use Electrical box: IPX4 CH1 0.1 15 to 25 V HRLE Basic dual type V (CH1, 2 (CH1, 2 Scheduled to acquire UL
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bore size (Stroke (mm)) 8 12 16 20 25 25, 50, 75, 100, 125, 150 50, 75, 100, 125, 150 75, 100, 125, 150, 175, 200 100, 125, 150, 175, 200, 225, 250 100, 125, 150, 175, 200, 225, 250, 275, 300 Auto switch Nil Without