Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Screwdriver Operated Style, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 100VAC 50/60HZ, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 110VAC 50/60HZ, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 12VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: Surge Suppressor, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M Plug w/o Connector, Surge Suppressor: Surge Suppressor, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Manually Operated, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M Plug Connector w/o Lead Wire, Surge Suppressor: None, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M8 Connector w/o Cable, Surge Suppressor: Surge Suppressor, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 12VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: None, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 100VAC 50/60HZ, Lead Wire: L Plug w/o Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Option: -, CE Compliant: -
Hexagon socket head cap screw C (M4 x 5L) Switch mounting rod mounting tap (3 locations) Switch mounting rod mounting tap (3 locations) (Attached to auto switch) Hexagon socket head cap screw A (M2.5 x 11L) Auto switch Hexagon socket head cap screw (M3 tightening torque: 0.5 to 0.7 Nm) Auto switch mounting bracket Plugged Hexagon socket head cap screw B (M4 x 8L) Switch mounting rod E Auto
In order to hold the locked state, be sure to follow the steps below after confirming safety. 1) Remove the dust cover (1). 2) Supply air pressure of 0.2 MPa or more to the unlocking port (2) shown below and unlock. 3) Screw the attached hexagon socket head cap bolt (3) (20, 25: M3 x 0.5 x 5l, 32: M3 x 0.5 x 10l), into the lock ring to hold the unlocked condition. 2.
SP158X-002E P: TS P.G.Information (Specialized Product) SMC Corporation 4-14-1, SOTO-KANDA, CHIYODA-KU, TOKYO 101-0021, JAPAN URL: http://www.smcworld.com Liquid Dispense Pump (Solenoid type) Series LSP Features Compact solenoid type diaphragm pump, which dispenses fixed amount of liquid from 5L to 200L each time it is operated.
Model: 42 (Dual AC Type), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 5L (ø3/16" Elbow)
25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Approx.2200W(water), 1500W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN HT-135 Fluorinert FC-77, FC-3283) Recirculating fluid Reservoir capacity : Approx.5L
./ 80L/min(ANR)(SUP=0.14MPa) *3 200L/min(ANR)(SUP=0.4MPa) 5L/min(ANR)(SUP=0.14MPa) *3 11L/min(ANR)(SUP=0.4MPa) 2080() 2060( ExdBT5) ExdBT5(TC15916) A A Rc1/4 1/4NPT G1/4 Rc1/8 A G1/2M20X1.51/2NPT G1/2 2.6kg 2.4kg JISF8007 IP65(IEC Pub.529) *11/21/2%F.S.
In order to hold the locked state, be sure to follow the steps below after confirming safety. 1) Remove the dust cover (1). 2) Supply air pressure of 0.2 MPa or more to the unlocking port (2) shown below and unlock. 3) Screw the attached hexagon socket head cap bolt (3) (20, 25: M3 x 0.5 x 5l, 32: M3 x 0.5 x 10l), into the lock ring to hold the unlocked condition. 2.