Slotted set screw (M2.5 x 4l) (included) Flat head watchmakers screwdriver Auto switch Auto switch Auto switch mounting surface Magnetic substances such as an iron plate should be separated at least 15mm away from auto switch mounting surface. Magnetic substances may cause unstable operation of the auto switch.
DC (+) Brown 0.5 7 7 7 Lead wire length (m) 3 32 32 32 Switch main circuit Switch main circuit Switch main circuit OUT Black 5 52 52 52 DC () Blue Dimensions D-F8N, D-F8P, D-F8B D-F8P Mounting screw M2.5 x 4l Slotted set screw DC (+) Brown 4.3 Indicator light 2 2.7 OUT Black 10 2.8 4.6 DC () Blue 3.1 10.9 3 D-F8B OUT (+) Brown 4 Most sensitive position 8 OUT () Blue 8
0.3 VDW20 VDW20 3.2 CV = 0.3 VDW20 2.3 CV = 0.18 VDW30 VDW30 3 CV = 0.28 VDW30 3 CV = 0.28 VDW20 VDW20 2.3 CV = 0.18 VDW30 2 CV = 0.16 VDW30 VDW30 2 CV = 0.16 10 Flow rate Ql /min VDW 1.6 CV = 0.07 10 20 VDW VDW 1.6 CV = 0.07 10 20 5.0 VDW10 VDW10 1 CV = 0.03 VDW10 1 CV = 0.03 1.0 0.1 0.001 0.01 0.1 1 10 Pressure differential P = (P P) MPa Viewing the graph To generate a water flow of 4l
Unit: g Model D-M9N D-M9B D-M9P 0.5 8 7 8 Lead wire length m 3 41 38 41 Auto Switch Dimensions Auto Switch Internal Circuit D-M9 M2.5 x 4l mounting hole Slotted set screw Indicator light D-M9B, N, P D-M9N DC(+) Brown 2.6 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC(-) Blue 3.2 D-M9N, P (3-wire) D-M9P Most sensitive position 6 DC(+) Brown 22
M5) A1 A C4H 4mm5/32 inch C6H 6mm A2 B NH7 1/4 inch N7H A3 C C4L 4mm5/32 inch C6L 6mm B N7L 1/4 inch D + N NPN1 P PNP1 A NPN2 B PNP2 C NPN1+ D NPN1+ E PNP1+ F PNP1+ 1 L (2 m) 1 (2 m 1 G 1 M SI2 P (psi)1 1NP3 4 1 2kPaMPa -8No.PS-OML0002CN-G / A ZS-38-A1 (M35 L 2 ) B ZS-38-A2 (M35 L 2 ) C ZS-38-A3 (M35 L 2 ) ZS-27-C (M38 L 2 ) + ZS-27-D (M38 L 2 ) ZS-38-3L 3 1 2m ZS-38-4L
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket), Calibration
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration
Digital flow switch for de-ionized water & chemicals ; Remote type sensor unit ; Flow rate range: 0.4 to 4l/min ~ 4 to 40l/min ; Output for display unit with or w/o analog output ; Port sizes: 3/8", 1/2", 3/4"
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 16mm, Stroke: 15mm, Cylinder Rod Motion: Normally Retracted, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: Light & Surge Suppressor, Auto Switch: Rail Mounting, Number: -
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 16mm, Stroke: 15mm, Cylinder Rod Motion: Normally Extended, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: Light & Surge Suppressor, Auto Switch: Band Mounting, Number: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 10mm, Stroke: 30mm, Cylinder Rod Motion: Normally Extended, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: Light & Surge Suppressor, Auto Switch: Rail Mounting, Number: -