Model: -, Orifice Size: -, Style: -, Fluid Option: -, Suffix: -, Port Size: -, Thread: -, Voltage: -, Lead Wire: -, Surge Suppressor: -, Rectifier: -, Bracket: -
Compatible Fluid: -, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Open, Application: Individual Item, Connection Type: NPT, Plumbing Thread Nominal: 3/4, Driving Type: Pilot Type, Insulation Class: B, Voltage: 110 V AC 50/60 Hz, Sealing materials: NBR, Option: None, Body Material: CAC408, copper, Detailed type:
Pilot: R (External Pilot), Port Size: 06 (3/4"), Thread: N (NPT), Safety Switch, Wiring: M (M12 Connector, OMRON), Check Valve, External Pilot Only: B (Applicable Tube O.D. ø5/16")
Pilot: R (External Pilot), Port Size: 06 (3/4"), Thread: N (NPT), Safety Switch, Wiring: S1 (M12 Connector, Rockwell Automation), Check Valve, External Pilot Only: B (Applicable Tube O.D. ø5/16")
Pilot: R (External Pilot), Port Size: 06 (3/4"), Thread: N (NPT), Safety Switch, Wiring: S1 (M12 Connector, Rockwell Automation), Check Valve, External Pilot Only: None
Pilot: R (External Pilot), Port Size: 06 (3/4"), Thread: N (NPT), Safety Switch, Wiring: M (M12 Connector, OMRON), Check Valve, External Pilot Only: None
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Low Vacuum Compatible / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: [Others] 2 positions universal, Pipe Port Type: NPT, Port Size: 3/4, Pressure Rating(MPa): -0.1 to 0.9, Driving
Pilot: External Pilot, Port Size: 3/4", Thread: NPT, Safety Switch, Wiring: M12 Connector, OMRON, Check Valve, External Pilot Only: Applicable Tube O.D. ø5/16"
Pilot: External Pilot, Port Size: 3/4", Thread: NPT, Safety Switch, Wiring: M12 Connector, Rockwell Automation, Check Valve, External Pilot Only: Applicable Tube O.D. ø5/16"
Pilot: External Pilot, Port Size: 3/4", Thread: NPT, Safety Switch, Wiring: M12 Connector, Rockwell Automation, Check Valve, External Pilot Only: None
Pilot: External Pilot, Port Size: 3/4", Thread: NPT, Safety Switch, Wiring: M12 Connector, OMRON, Check Valve, External Pilot Only: None
Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 06 (3/4), Thread: N (NPT), Passage: External Pilot (N.O/N.C), Option: E (Continuous Duty), CE Compliant: Q (CE Compliant)
Pilot: External Pilot, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: None, Port Size: 1/2, Thread: NPT, Passage: External Pilot (N.O/N.C), Option: Continuous Duty, CE Compliant: CE Compliant
Pilot: R (External Pilot), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: N (NPT), Passage: External Pilot (N.O/N.C), Option: E (Continuous Duty), CE Compliant: Q (CE Compliant)
[%F.S.] 2 1 0 OUT OUT OUT OUT 0 D 2D 3D 4D 5D IN IN IN IN 0 1 2 3 4 5 5 (5D) [] [] LFE13/8 inch 0.2 MPa LFE23/4 inch LFE31 inch (mm) D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 68 No.LFE*-OMY0008 4.0 3.5 3.0 2.5 [%F.S.]
32 3C 0D 06 32 OD Set at 25.0 deg.C 31 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D 01 32 02 34 30 38 30 03 30 30 0D Answer ERR11 Answer -1.52 deg.C Reading offset 01 32 05 36 36 3D
31 32 35 30 30 03 32 3C 0D 06 32 OD Set at 25.0 deg.C 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D 01 32 02 34 30 38 30 03 30 30 0D Answer ERR11 Reading offset 2 01 32 05 36 36 3D
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061)
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061)
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals)