/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt fixing brackets 2 pcs. (including 4 M10 bolts) Note 10) Weight (dry state) kg Approx. 130 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less. Note 2) Use fluid in condition below as the circulating fluid.
1 pc. (4) Barrel nipple 25A 1 pc.
Electrical option Nil None S With surge voltage suppressor L With indicator light Z With surge voltage suppressor/indicator light Body size 4 15A 5 20A 6 25A 7 32A 8 40A 9 50A Refer to Table 2 below for applicability.
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.
Operate in a range such that the cylinder pressure is less than two times the supply pressure. 00 51 Applicable solenoid valve 1 2 VQ54 VQ5 VVQ5000-25A-1 (plug-in type) VVQ5000-25A-5 (plug lead type) Can hold an intermediate cylinder position for an extended time When combined with a double check spacer with built-in double check valve, it is unaffected by air leakage between the spool valves
Size: 4 [ø25(ø16)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: FPM seal, Thread: F [G(PF)], Port Size: 1, Voltage: 24VDC, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 4 [ø25(ø16)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: FPM seal, Thread: NPT, Port Size: 1, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 4 [ø25(ø16)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: FPM seal, Thread: NPTF, Port Size: 1, Voltage: 24VDC, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 4 [ø25(ø16)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: FPM seal, Thread: NPT, Port Size: 1, Voltage: 24VDC, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: Port Size 1, Number of Ports: 3 Port, Valve Type: 3 [NC (Operating Pressure 7.0MPa)], Gasket: NBR Seal, Thread: Rc(PT), Port Size: 1, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Bracket: -, CE Compliant: -
Size: Port Size 1, Number of Ports: 3 Port, Valve Type: 3 [NC (Operating Pressure 7.0MPa)], Gasket: FKM Seal, Thread: Rc(PT), Port Size: 1, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Bracket: -, CE Compliant: -
Size: Port Size 1, Number of Ports: 3 Port, Valve Type: 1 [NC (Operating Pressure 3.5MPa)], Gasket: NBR Seal, Thread: Rc(PT), Port Size: 1, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Bracket: -, CE Compliant: -
Compatible Fluid: Coolant, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 25, Voltage: 24 V DC, Sealing materials
Compatible Fluid: Coolant, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 25, Voltage: 24 V DC, Sealing materials
Compatible Fluid: Coolant, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Open, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 25, Voltage: 24 V DC, Sealing materials
Compatible Fluid: Coolant, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Open, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 25, Voltage: 24 V DC, Sealing materials
Compatible Fluid: Coolant, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 16, Voltage: 24 V DC, Sealing materials
Compatible Fluid: Air / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 25, Voltage: 24 V DC, Sealing