AN20-02 AN20-02 AN20-02 AN40-04 AN40-04 Air operated type AN20-02 AN40-04 AN40-04 VXF(A)21AA(B) VXF(A)22AA(B) VXF(A)23AA(B) VXF(A)24AA(B) VXF(A)25AA(B) VXF(A)26AA(B) Note) Spring is shipped together with the product, but not assembled. 9 2 Port Solenoid Valve/Air Operated Valve For Dust Collector Series VXF2/VXFA2 Construction Solenoid Valve Type Air Operated Type VXF2 B<
(Max. 20 stations) SUP/EXH block assembly mounting position Valve stations Series 3 5 7 02 2 stations SY3000 SY5000 SY7000 20 20 stations Symbol Mounting position U side D side Both sides Special specifications Applicable stations U D B M 2 to 10 stations 2 to 20 stations In case of special specifications, indicate separately on a manifold specification sheet.
Specifications PF2A703H PF2A706H Dry air, Nitrogen Heater type 300 to 6000 l/min PF2A712H Model Measured fluid Detection type Rated flow range Note 1) 600 to 12000 l/min 10 l/min 150 to 3000 l/min 5 l/min Minimum set unit Note 1) l/min, CFM l, m3, m3 x 103, ft3, ft3 x 103, ft3 x 106 Note 2) Display units Real-time flow rate Accumulated flow Operating pressure range Proof pressure Pressure
) 98 (108) N M 82 (92) 93 (103) 98 (108) M 82 (92) 93 (103) 98 (108) Normally open Normally closed VXD2270 VXD2380 VXD2390 VXD2272 32A 40A 50A VXD2382 VXD2392 48 50 50 95 97 97 62 64 64 160 170 180 135 140 155 67.5 70 77.5 168 (185) 182 (197) 194 (209) 51.5 54.5 59 100 105 120 36 42 53 23 25.5 25.5 35 40 40 12 14 14 41.5 44.5 44.5 ( ): N.O. 17-3-41
1 103 4 7 10 20 40 70 100 200 Flexing radius [mm] 10.5 Inrush currents at power-on of main circuit and control circuit The following table indicates the inrush currents (reference data) that will flow when the maximum permissible voltage (200V class: 253VAC, 400V class: 528VAC) is applied at the power supply capacity of 2500kVA and the wiring length of 1m (3.28ft).
O.D. 4 2.5 1 4 1 4 3 8 KFF04-02 KFF06-02 KFF06-03 KFF08U-02 KFF08N-02 KFF10U-02 KFF10N-02 KFF12U-02 KFF12N-02 10 33.5 26.8 15 15 17 1.6 25 27 30 17 17 19 15.5 1.5 33.2 26.5 6 15.2 3 12 6 4 35.2 28.5 5 6 11 17 21 30 35 45 4 5 5.5 6.5 7 8 Connection thread Applicable tubing 14 17 1 4 33.2 26.5 15 16.2 28 8 10 6.5 7.5 1 4 32 17 17 34.8 27.5 15 18.8 12 8 9 35 36 1 4 19 17 35.3 28.5 15 19.3 15
-02 KPGL08-01 KPGL08-02 KPGL10-02 KPGL10-03 KPGL12-03 KPGL12-04 KPQL04-M5 KPQL04-01 KPQL04-02 KPQL06-M5 KPQL06-01 KPQL06-02 KPQL08-01 KPQL08-02 KPQL10-02 KPQL10-03 KPQL12-03 KPQL12-04 17 21 25 18.5 23.5 27.5 26 30 33 34.5 37 39.5 8 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 8 10 14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 4 4 18 10.4 20.7 D1 10 L2 A D2 8 H 6 10 10 19.5
M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position
Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21
A, B port) (Light/surge voltage suppressor) 80 [87] 57.5 [64.5] + 64.6 42.1 36.5 25.5 20 12 43.6 22 22 11.5 34 18 1/4 (R1, R2 port) 31.5 63 L plug connector (L): SYJ7240-L01 02 M plug connector (M): SYJ7240-M01 02 DIN terminal (D): SYJ7240-D01 02 M8 connector (W0): SYJ7240-W001 02 Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 91 83.5 57.5 [64.5] 72.2 42.1 M8 x 1 62 57.1 (
-02-08/AN200-2 Speed controller/Silencer 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 10 x 1 m) Speed controller/Silencer AS3301F-02-10/AN200-2 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 12 x 1 m) Speed controller/Silencer AS4001F-02-12/AN200-2 It is when the cylinder is
14 17 R 1/4 41.2 46.2 46.7 51.7 18.5 AS22 1FE-02-08SK 18.5 36.4 27.2 8 15.2 39 AS-FE AS-FE AS22 1FE-02-10SK 21 44.5 18.8 35.3 10 18.5 42 AS32 1FE-03-06SK 17 39.3 27.8 6 12.8 57 KE AS32 1FE-03-08SK 18.5 41 29.5 8 15.2 60 14 19 R 3/8 46.5 51.5 51.7 56.7 23 19.8 AS32 1FE-03-10SK 21 43.3 31.8 10 18.5 62 AS-FG AS32 1FE-03-12SK 22 44.3 32.8 12 20.9 64 AS42 1FE-04-10SK 21 47.9 33.6 10 18.5 103
47.2 52.2 18.5 Applicable tubing O.D. d AS221FE-02-08SK 18.5 36.4 27.2 8 15.2 39 AS221FE-02-10SK 20 21 43.2 33.9 10 18.5 42 AS321FE-03-06SK 16 39.3 27.8 6 12.8 57 AS321FE-03-08SK 18.5 41 29.5 8 15.2 60 R 3/8 19 14 46.5 51.5 52.8 57.8 20.9 23 AS321FE-03-10SK 21 43.3 31.9 10 18.5 62 AS321FE-03-12SK 22 44.3 32.8 12 20.9 64 AS421FE-04-10SK 21 47.9 33.6 10 18.5 103 R 1/2 24 17 51.5 56.5 59.7
Description AXT336-1A-1 01 02 01 02 01 02 02 03 02 03 02 03 02 03 Manifold block assembly AXT336-1A-2 AXT336-1A-3 AXT336-2A-1AXT336-2A-2AXT336-3A-1AXT336-3A-2q End plate (U side) assembly w End plate (D side) assembly e Terminal assembly Junction cover assembly Tie-rod r t y Replacement Parts No. u Description Material Carbon steel NBR NBR Part no.
(P . 103) Part no. Refer to How to Order for the standard model number. (P . 103) Strokes in 1 mm intervals are available by using an exclusive body with the specified stroke. Strokes in 1 mm intervals are available by installing a spacer in the standard stroke cylinder.
BA-32 BA-04 BA-05 BA-06 BA-08 BA-10 D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C BM1-01 BM1-02 BM1-32 BM1-04 BM1-05 BM1-06 Note) Two kinds of auto switch mounting brackets are used as a set.
BA -01 CX D-G5NBL 35 40 45 45 45 40 50 45 D-G5/K5 D-B7/B8 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 BM1 -06 Since this is a guideline including hysteresis, not meant to be guaranteed.
Circulating Fluid Typical Physical Property Values Ethylene Glycol Solution 20% Temperature [C] Density [kg/m3] Specific heat C [J/(kgK)] 10 1.03 x 103 3.93 x 103 20 1.03 x 103 3.95 x 103 30 1.02 x 103 3.97 x 103 40 1.02 x 103 3.98 x 103 50 1.01 x 103 4.00 x 103 60 1.01 x 103 4.02 x 103 Water Density g: 1 x 10 3 [kg/m 3] Specific heat C: 4.2 x 10 3 [J/(kg K)] 6 Thermo-con/ Rack Mount Type
Cooling capacity = Considering a safety factor of 20%, 93.3 W x 1.2 = 112 W Circulating Fluid Typical Physical Property Values Ethylene Glycol Solution 20% Temperature [C] Density [kg/m3] Specific heat C [J/(kgK)] 10 1.03 x 103 3.93 x 103 20 1.03 x 103 3.95 x 103 30 1.02 x 103 3.97 x 103 40 1.02 x 103 3.98 x 103 50 1.01 x 103 4.00 x 103 60 1.01 x 103 4.02 x 103 Water Density : 1 x 10 3
Product Specifications Voltage drop 103 - 21. Memory map list The memory map according to the mode is shown below. Please refer to 10. Memory map for details of each signal.