Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: G, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Light
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPTF, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPTF, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPTF, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPTF, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPTF, Voltage: 200VAC 50/60HZ, Lead Wire: Grommet, Surge Suppressor: Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: G, Voltage: 200VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: G, Voltage: 240VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 32A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (32A)], Thread: NPT, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Surge Suppressor
, Ion exchange resin*12 Temperature range [C] 5 to 40 Pressure range [MPa] 0.3 to 0.5 Required flow rate (50/60 Hz)13 [L/min] 8 12 Facility water system Inlet-outlet pressure differential of facility water [MPa] 0.3 or more Port size Rc3/8 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Synthetic rubber Power supply Single-phase 100 VAC (50/60 Hz), 115 VAC
(For communication cable) Weight*9,*12 kg 134 *1 Use fluid that fulfills the conditions below as the circulating fluid.
VP7-8: Flow Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) Flow characteristics Type of actuation Valve model Port size Single 12 12 12 12 13(6.8) 7.5 7.5 7.5 7.5 7.6(6.1) 0.30 0.30 0.30 0.30 0.32(0.35) 0.32 0.32 0.32 0.32 0.34(0.23) 3.1 3.1 3.1 3.1 3.3(1.8) 2.0 2.0 2.0 2.0 2.1(1.6) 13 13 13 14(13) 12 7.6 7.6 7.6 7.6(7.6) 7.6 0.30 0.30 0.30 0.30
For Y terminal, it is up to 1.25 mm2 4. c Cable (8) external: 6 to 12 mm Note) For the one with the external dimension ranged between 9 to 12 mm, remove the inside parts of the rubber seal (7) before using. Supply air Install an air filter and a lubricator on the upstream side. Lubrication This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
Cooling Capacity HRS100-A -20/40(50 Hz) HRS100-A -20/40(60 Hz) 14 14 12 12 Ambient temperature 90F (32C) Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 90F (32C) Ambient temperature 104F (40C) Ambient temperature 104F (40C) 8 8 6 6 4 4 Ambient temperature 113F (45C) Ambient temperature 113F (45C) 2 2 0 0 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] 41 [5]
x V x C x iT it m x C x (T0 Tt) it Q = = 1 x 250 x 4.186 x 103 x 12 900 = = 13953 [J/s] 14.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 14.0 [kW] x 1.2 = 1 x 250 x 60 x 1.0 x 103 x 12 15 x 860 16.8 [kW] = Thermo-chiller Q x t: Heat capacity [kJ] 13953 [W] = 14.0 [kW] Water bath 20C Cooling capacity = Considering
In that case, loosen the screw with washer o and place a lead wire into the bracket , and then tighten it once again. b The maximum size for the round terminal o is 1.25 mm23.5 and for the Y terminal is 1.25 mm24. c Cable i outside diameter: 6 to 12 mm Note) For the one with outside diameter ranged between 9 to 12 remove the inside parts of the rubber seal u before using. 3.
OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC FUNC FUNC U Blue DC () Blue DC () -E PNP (1 output) + Analog voltage output -F PNP (1 output) + Analog current output Brown DC (+) Brown DC (+) Black OUT1 Black OUT1 + + White OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC Load Load FUNC FUNC U Blue DC () Blue DC () The FUNC terminal is connected when using the copy function.