H 13 6.5 6.5 13 B A 3.2 6.5 7 7 15 1 3H9 depth 3 +0.025 0 4 NN-M4 x 0.7 thread depth 8 B A 3H9 depth 3 +0.025 0 HA GA Section AA Section BB (mm) ZZ 74 79 90 108 126 176 M 49 54 65 83 101 151 Z 48.5 53.5 64.5 82.5 100.5 150.5 K 23.5 33.5 43.5 53.5 63.5 88.5 J 19.5 29 39 56 60 96 I 13 8.5 9.5 10.5 24.5 38.5 NN 2 2 3 3 4 5 HA 20 30 20 28 46 56 H 28 30 20 28 23 28 GA 17 12 33 43 43 83 G 9 12
Bellows assembly (7) XL1A16-2-101 XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No. Bellows assembly (7) XL1A63-2-101 XL1A80-2-101 Nut assembly (9) XL1A50-10-1 XL1A80-10-1 Note 1) Bellows assembly contains the valve seal 1. It does not contain the valve seal 2.
VVQ2000-51A-C8 VVQ2000-51A-C10 Note) When replacing a pilot valve assembly only, note that SY114 (G, H, L, M) cannot replace SY115 (DIN terminal) or vice versa.
H G H G H G H 178.5 105.5 73 42.5 50 Indicator light 164.5 178.5 11 (12.5) 4(A) port 11 (12.5) 2(B) port 59 73 42.5 105.5 Indicator light 50 11 (12.5) 11 (12.5) 2 4 4(A) port 2(B) port 24.6 38 48 4 2 B A 24.6 A B 38 48 14 12 5 3 1 B A 30 45 14 3 5 1 12 2-5.6 Mounting hole Manual override 2-5.6 Mounting hole 45 30 Manual override 14.5 27 30.5 32 41.5 91.5 129 79 PE X PE X 32 41.5 30.5 27 R1
(mm) Electrical entry P Port size B C D E F H K L M N A Model Grommet: G Conduit: C Conduit terminal: T Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
Calculation: (Example) CLJ2L16-60 Basic weight320 (16) Additional weight6.5/15 stroke Cylinder stroke60 stroke 320 + 6.5/15 x 60 + 27 = 373 g 4 4.4 5 3 2 1 Stopping Accuracy (Not including tolerance of control system.)
Calculation: (Example) CLJ2L16-60 Basic weight320 (16) Additional weight6.5/15 stroke Cylinder stroke60 stroke 320 + 6.5/15 x 60 + 27 = 373 g 4 4.4 5 3 2 1 Stopping Accuracy (Not including tolerance of control system.)
Torque Gravity Due to Acceleration US System (g) = 32.2 feet per sec. per sec.
Torque Gravity Due to Acceleration US System (g) = 32.2 feet per sec. per sec.
(mm) Electrical entry P Port size B C D E F H K L M N A Model Grommet: G Conduit: C Conduit terminal: T Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 XL1A63-2-101 XL1A80-2-101 XL1A50-10-1 XL1A80-10-1 112 2 1 FKM:No.1349-80 [] XL1A16-2-101-XN1 EPDM Barrel Perfluoro Kalrez Chemraz VMQ FKM for R R R PLASMA No. 2101-80 70W 4079 SS592 SS630 SSE38 1232-70 3310-75 -XN1 -XP1 -XQ1 -XR1 -XR2 -XR3 -XS1 -XT1 R 1Barrel Perfluoro R Kalrez Chemraz
-10 (INC) c 10[mm] 0 10 20 30 40 50 [mm] -27- 4 a b c d e f g h i j k No. 1 2 mm/s mm mm/s^2 mm/s^2 % % mm/s % mm mm mm 0 ABS 100 20.00 3000 3000 80 40 30 100 10.00 20.00 20.00 No.00[mm] 20[mm]20[mm] 1 10 W [mm] c [mm] k 20 0 10 20 30 40 50 [mm] INP 2 k INPON g 30 W [mm] c [mm] k 20 0 10 20 30 40 50 [mm] INP INPOFF () k g BUSYONOFF -28- 5 a b c d e f g h i j k No. 1 2 mm/
No. of connecting tubes Model Weight Color of release button KDM10-23 KDM10-04 KDM10-06 KDM10-08 KDM20-23 KDM20-04 KDM20-06 KDM20-08 3.2 4 6 300 g 10 520 g 8 3.2 Blue 520 g 4 6 8 20 950 g KDM20 Applicable Tubing Tubing material Tubing O.D.
A OUT IN OUT IN A G H H M M AR50, 60 AR30, 40 J G J G A A IN OUT IN OUT H M M H Parts list Material Note No.
1/16 (2) (1) Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 0.06 0.26 0.21 0.44 0.47 1.17 1.22 Note 1) Pressure gauge connection threads are not required for regulator with a square embedded type pressure gauge (AR20 to AR60).
F Nil Rc G N T NPT NPTF Brackets are not installed.
1 G 02 F With bracket For type 30 manifold Not installed when delivered.
Pressure Sensor/Sensor Range ZSM Sensor supply pressure 101 to 101 kPa (Compound pressure) (Vacuum) (Low pressure) (High pressure) PF2 PSE533 10 to 101 kPa 10 to 101 kPa 0.1 to 1 MPa Regulating pressure range PSE531 PSE532 PSE530 Applicable pressure sensor IF SET If the controller is equipped with a unit switching function, unit setting can be changed.
M5 x 0.8 Y G: M6 x 1 G: M8 x 1.25 G: M4 x 0.7 G: M5 x 0.8 D ZPY02U 2 4 6 8 Applicable tube O.
From Table 3.7: At 1soo, 10 m3 of air can hold a maximum of 13.04g/m..10m" = 130.4 g P N E U A T I c T E c H t t o L o G Y At 650/o r.h. the air will conlain 130.4 g '0.65 = 84.9 g {a) The reduced volume ol compressed air at 6 bar pressur can be calculated: pl'v1 = pzvz = p; v1 = v2 = +H# '10 m3 = 1.44 mc From Table 3.7 1.44m3of air at 25oC can hold a maximum of 23'76 g '1 '44 = 34.2 g (