Page 33 Model Selection .Page 37 Flow Rate Characteristics . Page 39 Purge Air Flow Rate Charts ... Page 41 Precautions .
Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 22 36 110 180 544 612 873
type GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS Pressure gauge G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 Round G46-2-02 G46-2-02 0.2MPa Note 4) Square embedded type GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.
T orque 4 : 4.4 LB . in 1 .39 (9.9) RECEPTACLE WITH .37 (9.4) SPACING 1.02 (25.9) .13 (3.3) DIA.
38 41 32 33 34.5 37 35.5 37 39.5 44.5 46 1 4 17 18.5 26.5 21 17 10 3 8 1 2 25.0 35.2 22 1 4 17 3 8 1 2 3 8 1 2 20.9 12 28.5 22 17 39.7 50.2 22 (71) (84) 71 100 26.5 22 20.9 34 25 16 Reference dimensions after R(PT) thread installation.
80 65 0.074 0 250 to 1000 16 110 80 10 13 95 20 25 63 30 90 116 40 37 100 80 0.074 Bore size (mm) ZZ Y 6.8 to 11.3 WH 335 X 10 P 30 S 1/2 NF 215 NE 24 ND 25 MM 27.7 M M18 x 1.5 LZ 7.5 LX 73 LY 53 LT 88.5 LS 10 LH 275 52 50 342 10 37 1/2 215 24 24.5 27.7 M18 x 1.5 7.5 80 60 95 10 289 55 63 371 8.5 to 13.5 13 40 3/4 228 32 30.5 37 M22 x 1.5 10 100 75 115 12 308 65 80 391 13 47 3/4 236 41 34
(Refer to p.4.9-5) Caution Model Recommended SMC speed controller Caution Model Elbow Straight In-line REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC32 AS3201F-01-08-X214 AS3001F-08-X214 AS3201F-01-08-X214 REC40 AS3201F-02-08-X214 AS3001F-08-X214 AS3301F-02-08-X214 4.9-3 Be sure to read before handling.
For details about the follwing auto switches (D-B76/B73/B73C/G79/K79/K79C/B80/B80C), please inquire of us. 8-21-37
plug connector with cover (LL) 52-SY5120-LL-01 (-F2) Insulation: Red (+) Insulation: Black () 4.1 0.3 mm2 12 14.7 L 104 (Lead wire length) Cable type (TT) 52-SY5120-TT-01 (-F2) Lead wire marking No.1 (+), No.2 () 5.9 0.75 mm2 L 120.8 (Lead wire length) Max.10 5 ATEX Compliant Body Ported Type Series 52-SY5000 Dimensions 2-position double L plug connector (L) 52-SY5220-L-01 (-F2) 22.6 16.7
Note 2) ( ): Denotes without sub-plate. 267 Single Unit/Sub-plate Type 10-SV Dimensions: Series 10-SV1000 2 position single/double, 4 position dual 3 port [M12 waterproof connector type] 10-SV100(R)-W-01 Directional Control Valves Air Grippers Modular F. R.
Model VQZ100 VQZ200 VQZ300 AN110-01 AN110-01 AN200-02 AN200-02 AN110-01 Refer to page 4-14-3 for silencer for single valve unit. 4-14-17 18 Series VQZ Option Body Ported External Pilot Specifications Inch-size One-touch Fittings and Option Threads External pilot specifications are used when the operating pressure is below the minimum operating pressure 0.1 to 0.15 MPa or when valve is used
(Comparison with current PB series) Weight Weight 0. 0.11kg kg Weight 0.11kg PB1013A/Air-operated type without foot 37 37 mm mm 52 mm 37 mm 52 52 mm mm 66 66 mm mm 66 mm Actual size (PB1013A) Application Examples Application Examples Application Examples Space saving (Air operated) Car washing machine Printing machine Semiconductor/ LCD equipment Analyzer for medical and biochemistry Water
37 44 32 40 48 56 3.2 3.2 4.5 4.5 37 37 42 42 21.5 18 16 18.5 182 215 281 325 144 166 188 230 Adapter Assembly Installation Procedure For details, refer to Best Pneumatics Vol. 16.
-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -02-08 AS2200-02 100 200 50 100 0
L 31 32 33 34 35 36 37 38 39 40 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 No.
AL.01 Contact output 2 function Sets output signal function of contact output 2. RMT Contact output 2 operation Sets output signal operation of contact output 2. A Contact output 2 selected alarm Sets alarm which is selected for contact output 2. AL.01 Contact output 3 function Sets output signal function of contact output 3.
AL.01 Contact output 2 function Sets output signal function of contact output 2. RMT Contact output 2 operation Sets output signal operation of contact output 2. A Contact output 2 selected alarm Sets alarm which is selected for contact output 2. AL.01 Contact output 3 function Sets output signal function of contact output 3.
AL.01 Contact output 2 function Sets output signal function of contact output 2. RMT Contact output 2 operation Sets output signal operation of contact output 2. A Contact output 2 selected alarm Sets alarm which is selected for contact output 2. AL.01 Contact output 3 function Sets output signal function of contact output 3.
AL.01 Contact output 3 function ALM Contact output 3 operation B Selected for contact output 3 AL.01 5.2 Function HRS Series 5-6 HRX-OM-O021 Chapter 5 Display and setting of various functions 5.3 Main screen 5.3.1 Main screen Displays the current temperature and the set temperature of the circulating fluid.
AL.01 Contact output 3 function ALM Contact output 3 operation B Selected for contact output 3 AL.01 5.2 Function HRS Series 5-6 HRX-OM-R005 Chapter 5 Display and setting of various functions 5.3 Main screen 5.3.1 Main screen Displays the current temperature and the set temperature of the circulating fluid.