ISE When the values of P1 and P2 are the same or when P1>P2 within three digits, the hysteresis will be automatically three digits for the set value of P1. Window comparator mode: ZSE The hysteresis is two digits, so separate P1 from P2 by five digits or more and set them.
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 L 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 6 JXCE1/91/P1/D1/L1 Series Options Controller setting kit JXC-W2 Power supply plug JXC-CPW The power supply plug is an accessory.
For saturated steam Viewing the graph [664] (183) Upstream pressure of valve P1 = 1.0MPa 1.0 The sonic range pressure to generate a flow rate of 25kg/h for orifice 3 (VCS21) is P1 approx. 0.68MPa for orifice 4 (VCS21) is P1 approx. 0.40MPa for orifice 5 (VCS21) is P1 approx. 0.29MPa The holding heat differs somewhat depending on the pressure P1, but at 25kg/h it is approximately 16000kcal
For saturated steam Viewing the graph [664] (183) Upstream pressure of valve P1 = 1.0MPa 1.0 The sonic range pressure to generate a flow rate of 25kg/h for orifice 3 (VCS21) is P1 approx. 0.68MPa for orifice 4 (VCS21) is P1 approx. 0.40MPa for orifice 5 (VCS21) is P1 approx. 0.29MPa The holding heat differs somewhat depending on the pressure P1, but at 25kg/h it is approximately 16000kcal
At this time, read vacuum pressure P1, obtain the suction flow rate from the flow-rate characteristics graph for the ejector that is being used, and render this amount as the leakage of the workpiece.
(condition P1 and Q1) 3. When suction port is opened further, suction flow moves to maximum value (Qmax), but vacuum pressure is near 0 (atmospheric pressure). When vacuum port (vacuum piping) has no leakage, vacuum pressure becomes maximum, and vacuum pressure decreases as leakage increases. When leakage value is the same as max. suction flow, vacuum pressure is near 0.
Subsonic flow at P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P (P2 + 0.1013) Sonic flow of P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) VER2000 Q: Air flow rate [/min (ANR)] S: Effective area [mm2] P: Amount of pressure drop P1 P2 [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Cylinder stroke (st/mm) Correction for varying air temperatures: Square the coefficient
SRH E 21 LQ2 SN SRP SRF SRF One nut (including insert bushing) of the nuts is not attached. Please refer to below Ordering example. Fitting type ITV E T Union elbow Union tee Applicable tubing size IC Class Applicable tubing size (inch) Applicable tubing size (mm) Reducing Reducing Class No. No.
Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 14-14-6 to 14-14-8 for precautions on every series. Suffix Basic size (Applicable compressor rating) T With terminal (Provided as standard for HAA37.)
Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 14-14-6 to 14-14-8 for precautions on every series.
Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).
Item Classification pD(Torrcm) /D (Knudsen number) >0.5 <0.01 Viscous flow 0.5 to 0.015 0.01 to 0.3 Intermediate flow <0.015 >0.3 Molecular flow 8 Exhaust time (low/medium vacuum) 4 5 1 2 3 4 1 2 3 The time (gt) required to exhaust a chamber at low vacuum with volume V (l), from pressure P1 to P2, using a pump with pumping speed S (l/sec) is gt=2.3(V/S)log(P1/P2).
No.ZB-OM00301 / ZB No.ZB-OM00301 2 9 12 13 15 16 16 V Assy 17 21 25 26 28 28 29 30 30 31 31 32 35 37 38 39 40 Assy 40 Assy 41 42 1 - No.ZB-OM00301 1) (ISO/IEC) (JIS) 2 *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.
Item Classification pD(Torrcm) /D (Knudsen number) >0.5 <0.01 Viscous flow 0.5 to 0.015 0.01 to 0.3 Intermediate flow <0.015 >0.3 Molecular flow 8 Exhaust time (low/medium vacuum) 4 5 1 2 3 4 1 2 3 The time (gt) required to exhaust a chamber at low vacuum with volume V (l), from pressure P1 to P2, using a pump with pumping speed S (l/sec) is gt=2.3(V/S)log(P1/P2).
OFF OFF OFF OFF P1 n1 P2 P1 n2 n1 (Standard: Factory setting) (Reversed) (Standard: Factory setting) (Reversed) Press the SET button to set the mode and proceed to the output type setting. 3 2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the set value.
OFF OFF OFF OFF P1 n1 P2 P1 n2 n1 (Standard: Factory setting) (Reversed) (Standard: Factory setting) (Reversed) Press the SET button to set the mode and proceed to the output type setting. 3 2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the set value.
Note 4) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).
OFF OFF OFF OFF P1 n1 P2 P1 n2 n1 (Standard: Factory setting) (Reversed) (Standard: Factory setting) (Reversed) Press the SET button to set the mode and proceed to the output type setting. 16-2-6 7 Series ZSE30/ISE30 High Precision, 2-color Display Digital Pressure Switch Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the set value
SYJ7000-16-2A SYJ7000-21-1 Gasket Base mounted ARBYJ5000-00-P Pillips head screw M3 X 47, matted nickel plated (With spring washer) DXT199-21-6 SYJ7000-21-3A Pillips head screw M3 X 55, matted nickel plated (With spring washer) Pillips head screw M3 X 8, matted nickel plated (With spring washer) Blank plate Base mounted SYJ7000-21-1 Gasket DXT199-21-6 Individual exhaust interface SYJ7000-
(Pilot port) (For mounting) 2-3.2 22 3 49 2.5 (For mounting) 2-3.2 equivalent (18.5) A B 1.5 11 17.5 Manual override A B 1.5 33 16 (18.5) (21) 18.9 13.5 15 54.5 Manual override 21.6 54.5 28.5 2-1 (Bleed port) 21 R2 P P1 P R R (11) (0.5) 13 10 5 2-1 (Bleed port) M5 x 0.8 (Piping port) 10 10 7 7 14 M3 x 0.5 28 (Piping port) 5-2-21 4/5 Port Air Operated Valve Series SYJA5000 How to Order A,