SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20CF-X-02-WB"

Symbol Position detector arms Switch bracket Positioning angle For the applicable auto switch model, refer to the table below. a b c d 10 11 12 13 14 15 20 23 25 180 X X X X X Data X X X X X X X 90 b d X Table position detector arm X X X X X X X a X Switch mounting bracket X X Cylinder Unit/Applicable Auto Switch Load voltage Lead wire length (m) Auto switch model Electrical entry Wiring

X X X X X X X X X X X X 90 X b d X X X Table position detector arm X X X X X X a Switch mounting bracket X Cylinder unit/Applicable auto switch types Load voltage Lead wire length (m) Auto switch part no.

WC WD WE WF XA XB XC YA YB YC Size 10 20 30 50 M8 x 1.25 12 M5 x 0.8 M4 x 0.5 M10 x 1 34 132.5 46 50 27.3 47 15 3H9 3.5 M5 x 0.8 8 32 27 3H9 3.5 19 3H9 3.5 M10 x 1.5 15 M6 x 1 M5 x 0.5 M12 x 1.25 37 168.5 58.5 63.5 39 54 20.5 4H9 4.5 M6 x 1 10 43 36 4H9 4.5 24 4H9 4.5 M10 x 1.5 15 M6 x 1 M5 x 0.5 M12 x 1.25 40 184 63.5 69 36.4 57 23 4H9 4.5 M6 x 1 10 48 39 4H9 4.5 28 4H9 4.5 M12 x 1.75 18

Brown Load Brown Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Leakage current Load impedance Load voltage at OFF = x 2 pcs. x Power supply voltage Internal voltage drop = 1mA x 2 pcs. x 3k = 6V Load voltage at ON = x 2 pcs. = 24V 4V x 2 pcs. = 16V Example: Load impedance is 3k Leakage current from switch is 1mA Example: Power supply is 24VDC Internal voltage

1.25 20 M8 x 1.25 6.6 32 25, 50, 75, 100 125, 150, 175 200, 250, 300 350, 400 91 69 16 12 10 54 14 10 14 120 M6 27 27 40 M8 x 1.25 20 M8 x 1.25 6.6 40 97 69 20 16 12 64 14 11 12 148 M8 32 32 46 M10 x 1.5 22 M10 x 1.5 8.6 50 102 74 20 16 12 78 16.5 13.5 16.5 162 M10 39 39 58 M10 x 1.5 22 M10 x 1.5 8.6 63 (mm) WB WA Bore size (mm) OB OL P PA PB PW Q R S T U VA VB 75st or less Over 75 to 175st

Finger Air Gripper Dimensions (mm) 1in = 25.4mm MHS2-50D, 63D 4-5.1, counter bore dia. 9.5 Counter bore depth SC (mounting hole) RA AA 6.4 AB AC 35 35 RA 5 VA, depth VB YC RB RB NA B XA, depth XB NB Q 4-M6 x 1, thread depth 12 (mounting threads) O 20 20 FX FY FZ (Open DO) (Closed DC) WA, depth WB 4-M5 x 0.8, thread depth 10 Attachment mounting threads CB CA M5 x 0.8 (finger opening port)

1.25 M12 x 1.25 M16 x 1.5 M16 x 1.5 M20 x 1.5 M20 x 1.5 Ports G1/8 G1/4 G1/4 G3/8 G3/8 G1/2 Cushioning stroke [mm] 19 19 24 24 30 30 Mounting position Any Standard strokes [mm] 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 (DIN ISO 4393) [mm] Other stroke lengths in accordance with ISO 497 R 10 Stroke tolerance [mm] <250mm: +1.0/-0mm, <1000mm: +1.4/-0mm Working pressure

#1+#5) : RSH Bore size -lll Basic w/locking mechanism w/cancel cap w/lever detection switch w/locking mechanism + cancel cap w/locking mechanism + lever detection switch w/cancel cap + lever detection switch w/locking mechanism+ cancel cap+ lever detection switch Stroke W Bore (mm) R S T U V WB X Y q SRSH Bore size A, #2 (#2+#5) : RSH Bore size -lll-D 50 30 72 40 21 2 5.5 15.5 32 5 10 24

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

D C B E1 L1 MM H A A1 R1 U1 d NDH10 NX 40 50, 63 80 100 I-04 I-05 I-08 I-10 NT-04 NT-05 NT-08 NT-10 21 25.4 22 8 69 22 24 55 M14 X 1.5 15.5 20 M14 X 1.5 12 16 +0.070 0 0.1 0.3 26 31.2 27 11 74 27 28 60 M18 X 1.5 15.5 20 M18 X 1.5 12 16 +0.070 0 0.1 0.3 31 37.0 32 13 91 37 36 71 M22 X 1.5 22.5 26 M22 X 1.5 18 28 +0.070 0 0.1 0.3 39 47.3 41 16 37 40 83 M26 X 1.5 24.5 28 M26 X 1.5 105 20 30

L NZ RR1 NX E1 L1 MM U1 ND A1 Cotter pin Polishing ball 12 Y-04C 40 +0.3 +0.1 16 38 M14 X 1.5 12 3 X 18l 22 24 55 13 25 55.5 Polishing ball 12 Y-05C 50, 63 +0.3 +0.1 16 38 M18 X 1.5 12 3 X 18l 27 28 60 15 27 55.5 Polishing ball 18 Y-08C 80 +0.3 +0.1 28 55 M22 X 1.5 18 4 X 25l 37 36 71 19 28 76.5 Polishing ball 20 Y-10C 100 +0.3 +0.1 30 61 M26 X 1.5 20 4 X 30l 37 40 83 21 38 83 Knuckle pins

Application examples Changing direction Positioning D-X Individual -X 409 Series MGF Model Selection Operating Conditions 1. Bore size: D (mm) 2. Operating pressure: P (MPa) 3. Mass of total loads: Wo (kg) Wo = (Load mass: WA) + (Jig mass: WB) 4.

Model Bolt Maximum tightening torque (Nm) l (mm) MGF40 MGF63 MGF100 7.5 10 M6 x 1 9 25 M8 x 1.25 9 51 M10 x 1.5 Mounting from bottom side Model Bolt Maximum tightening torque (Nm) l (mm) MGF40 MGF63 MGF100 7.5 18 M8 x 1.25 Example) 9 36 M10 x 1.5 9 65 M12 x 1.75 2. When mounting a workpiece to the cylinder, do so only when the piston is retracted.