SMC Corporation of America
Elite Part Number Search
Search Results "11-CDUJB6-15D"

It will cause failure or malfunction. 11. Do not use the product in an area where a magnetic field is generated. It will cause failure or malfunction. 12. Do not install the product in an environment containing flammable gas, explosive gas, or corrosive gas. It could lead to fire, explosion, or corrosion. 13.

ID 2 3 3 2 4 2147483647 0.01mm 4 1 5 0 6 H 2 065500 mm/s 7 L 8 H 2 0300 % 9 L 10 3 ID1 11 2 4 2147483647 0.01mm 12 1 13 0 14 0255 15 0255 4 16 0255 17 0255 18 IF(ID=1) 19 ID2 2039 ID1 ID3 4059 ID1 ID4 6079 ID1 ID5 8099 ID1 ID6 100119 ID1 ID7 120139 ID1 ID8 140159 ID1 33 - / Bit No.

End plate R (Output block side) How to order 11. Waterproof cap Mounted on the unused ports of the Input block, Output block and Power block. Proper use of this waterproof cap can achieve IP67 enclosure. (The waterproof caps are delivered together with the Power block as accessories.)

Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .

On : Output Off : Not output On, Off Off 11 Upper/Lower Temp. Alarm Sequence * How to return default value: Turn on the power supply with pressing [SEL] and [RET] keys.

No.EX-OMP0013-E PRODUCT NAME SI unit for EtherNet/IPTM MODEL / Series / Product Number EX260-SEN# Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Definition and terminology 10 Installation and Wiring 11 Installation 11 Wiring 12 LED Indication and Settings 16 Hardware configuration 19 EDS file and icon 19 Setting using RSLogix5000TM

29.5 31 25 11.5 14 16.5 26 28.5 7.5 10 12.5 30 32.5 32 12 13 15.5 25 27.5 8 9 11.5 29 31.5 40 15 20 20 32 32 11 16 16 36 36 50 14.5 21 21 33 33 10.5 17 17 37 37 The value of W in the table means the amount of auto switch protrusion from the body end surface.

Fittings & Tubing Air Cylinders Rotary Actuators How to Order 11 Vacuum suction type Clean series 11 M D H R 3 10 R M9B S 22 M D H R 3 10 R M9B S Copper, fluorine and silicone-free + Low particle generation Number of auto switches 2 pcs. 1 pc.

Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.

B H B H d C C d 10 8 21 M4 X 0.7 16.2 Y-J010B SNJ-006B 16 11 21 M5 X 0.8 16.6 Y-J016B M6 X 1.0 4 8 9.2 6 NTJ-006A 2.4 M3 X 0.5 6.4 5.5 6 SNJ-010B M8 X 1.0 4 11 12.7 10 NTJ-010A 3.2 M4 X 0.7 8.1 7 10 Part No.

Description Side cover Bearing retainer Bumper End cover A End cover B Inner cover Motor cover R Motor cover L Auto switch Magnet Brake Material Note 100W Ball screw/Slide screw 1 2 3 4 5 6 7 8 9 10 11 No.

M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9 90.2 91.9 90.2 91.9 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5

Elbow Universal 2 3 Metric size Inch size 3.2 23 01 1/8" 04 06 08 10 12 03 05 07 09 11 13 4 5/32" 6 3/16" Control 8 1/4" Meter-out Meter-in 0 1 10 5/16" 12 3/8" Use 1/8" tube. 1/2" M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 01 02 03 04 U10/32 N01 N02 N03 N04 Needle Valve/Flow Characteristics AS1201FG, AS1211FG AS2201FG-

Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.

Model AM850 AM250 AM350 AM450 AM550 AM650 AM150 Rated flow (l/min (ANR)) 750 1500 2200 3500 6000 12000 300 (1) Port size (Nominal size B) 1/8 ,1/4 ,3/8 1/4 ,3/8 ,1/2 3/8 ,1/2 ,3/4 1/2 ,3/4 ,1 3/4 , 1 1, 11/2 11/2 , 2 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note 1) Max. flow capacity at a pressure of 0.7MPa. It varies depending on operating pressure.

Model AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 AMG150 (1) Flow rate (l /min (ANR)) 750 1500 2200 3500 6000 12000 300 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 3/4, 1 1, 11/2 11/2, 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow is at 0.7MPa. Max. flow depends on operating pressure.

AMH X6 AMH X15 Body size Body size Options specification Options (Not available with element service indicator "T") Thread Accessories Thread Accessories Port size Port size Dimensions Dimensions Model Port size A 239 252 258 284 B 80 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 11/2, 2 AMH150 AMH250 80 Model Connection A 240 260 300 380 B 256 300 349 496.5 AMH450 AMH550

(Ex.: 2504-N002) Construction/Parts/Dimensions AN103 AN203 Construction/Parts/Dimensions VEX AN AMC AN303/403 AN200 to 900SAN, #1 to #8 AN202 to 402SAN, #9 to #11 AN103 to 403SAN, #12 to #15 5.2-2

+0 052 0 Depth 1.5 M5 X 0.8 (Finger closing port) M5 X 0.8 (Finger opening port) Auto switch mounting groove (4 locations) G 65 28.2 4-M6 X 1 H (Piston rod and rack screw) 6.5 1 11 15 10 24 14 Width across flats 10 20 46 24 (4 locations) A (70) 30 24 24 10 30 12.5 12.5 Closed E 54 Open F 17 17 4-M6 X 1 through (Thread for mounting attachment) A B C D E F G H 54 96 116 J 120 195 235 Model

) 3-M3 X 0.5 thread depth 6 44 MDHR2-15E port position 42 B 45 120o 11 120o A C 36 M3 X 0.5 M3 X 0.5 Finger opening port Finger closing port 10 M3 X 0.5 Finger opening port M3 X 0.5 Finger closing port 25o 25o MHZ2 MHZJ2 6-M3 X 0.5 thread depth 6 (A, B, C common view) MHQ 3-3 depth 6 +0.02 0 34 (A, B, C common view) MHL2 12h9 0 -0.043 Auto switch mounting groove MHR 1.5 .