When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, VALVE, SOFT START 3/4, VALVE, AV SOFT START UP BODY PORT, 1A, AV OTHER SIZE RATING, 3.93242 lb, ModelPort sizeProof

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)

This model is compatible with single phase 200 VAC 50/60Hz power. Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW, 2.2 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 200 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution

Cooling capacities: 10.5 kW, 15.7 kW, 20.5 kW, 25 kW, 28 Kw ; Temperature range setting: 5 to 35°C ; Temperature stability: ±0.1°C ; Power supply requirement: 3-phase 200 VAC, 50Hz or 3-phase 200 ~ 230 VAC, 60Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 11.5 kW, 15.7 kW, 20.6 kW, 24 kW ; Temperature range setting: 5 to 35°C ; Temperature stability: ±0.1°C ; Power supply requirement: 3-phase 200 VAC, 50Hz or 3-phase 200 ~ 230 VAC, 60Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 2 kW, 8 kW, 15 kW, 30 kW ; Temperature range setting: 20 to 90°C ; Temperature stability: ±0.3°C ; Power supply requirement: 3-phase 200 VAC / 50Hz or 3-phase 200~208 VAC / 60Hz ; Circulating fluid: Clear or deionized water, fluorinated liquid, or 60% ethylene glycol solution ; Standards: UL, CE, SEMI (S2-0703, S8-1103, F47-0200), SEMATECH (S2-93, S8-95)

Fluid fill and drain ports (800W, 1kW) on the front; Mechanical sealless magnet pump eliminates shaft seal leaks; Cooling/Heating capacities: 200W/600W, 400W/1kW, 510W/1.2kW, 800W/1.4kW, 1kW/2kW; Temperture stability: ±0.03°C or Better depending on load stability; Power supply requirement: 100 ~ 240 VAC (200-800W) or 200~240 VAC (1kW) (50/60Hz); Circulating Fluid: water or 20% ethylene glycol

Cooling capacities: 10 kW or 15 kW ; Temperature range setting: 5 to 35°C ; Temperture stability: ±1.0°C ; Power supply requirement: 3-phase 200 VAC 50 Hz or 200~230 VAC 60 Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

LVM20/200 is a compact direct operated 2/3 port solenoid valve for chemicals. LVM's unique internal chamber design reduces the swept volume to a minimum and can mean zero dead volume and carry over.  Operating pressure ranges from -75 kPa to 0.30 MPa. LVM20/200 is available as body ported, direct tube connection or base mounted.

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: Fluorinert™ or GALDEN® (see catalog for compatibility); Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Note: Temperature range depends on fluorinated fluid choice; Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8

Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: 60% ethylene glycol aqueous solution; Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8, F47

Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: tap water or DI water; Temperature range setting: 10 to 60°C; Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8, F47

Cooling capacities: 8kW; Circulating Fluid: Fluorinert™ or GALDEN® (see catalog for compatibility); Temperature range setting: -20 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8, F47

Cooling capacities: 8kW; Circulating Fluid: 60% ethylene glycol aqueous solution; Temperature range setting: -20 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8, F47

Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz); 200~230; STO (Safe Torque Off) safety function available; Display and settings buttons for direct input and status monitoring; Compliant with SEMI F47 Standard; SigmaWin+ Configuration software required (download available separately)

Positioning table available on LECSA (7 points) and LECSC (255 points); Compatible motors: 100/200/400W servo motors for 200~230 VAC; Display and settings buttons for direct input and status monitoring; Configuration software required (sold separately)