AFF Port size 3/4B 1/8B 01 02 03 06 10 14 AMl 1B 1/4B Note) Please refer to p.4.7-7 about "How to Order" case assembly. 3/8B 11/2B Related products 2B 20 04 1/2B Option combinations Available Not available D J R AMG150 AMG250 AMG350 AMG450 Applicable model Accessories Options C C D J R Accessories/Optional specification AMG550 AMG650 AMG850 Symbol N.C. auto drain N.O. auto drain Drain guide

Calculation D n W P t : Vacuum pressure (kPa) : Safety factor horizontal lifting: 4 or more vertical lifting: 8 or more : Pad diameter (mm) : Number of pads per workpiece : Lifting force (N) D = x x x t x 1000 1 P 4 3.14 W n Selection Graph After establishing the workpiece weight, number of pads to be used, and the vacuum pressure when adsorbing the workpiece, the pad diameters for horizontal

Amplifier lmpedance 100Ko 3ignal Voltage Range 0-1 0 vDc 0-svDc qppllcable Polentiometer 1OKA (1/8W or above) not provided itep Besponse 60ms (0.75A,95'/d )lther Frequency Adlustable Range 100-200 Hz (Factory adjusted @ 125H2) 12Q-19QHz (Factory adiusted @ 140H2) {ull Adjustable Range 0-0.5A (Factory adjusted @ 0A Sain Adlustable Range 5UU-/5UmA aI an InpUI voltage of 10V 500mA-14 at an input

F Port thread Rc Body size R Right to Left Nil 20 1/4 N NPT 30 3/8 F G 40 1/2 50 3/4, 1 Electric entry 1(P) 2(A) Port size Manual lockout Nil 1/4 (AVL2000) 02 D type DIN connector D Rated coil voltage 3/8 (AVL3000) 03 Port size D type DIN connector with indicator light & suppressor Manual lockout Nil B A 3(R) DZ 1/2 (AVL4000) 04 G 100VAC (50/60Hz) 1 3/4 (AVL5000) 06 D type DIN connector with

How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 40 8.

Series 10/11 -CQSX Series10/11 -CQ2X How to Order How to Order Clean room series 10 11 Clean room series 10 11 Relieving type Vacuum type Relieving type Vacuum type C(D)QSX B 20 10 30 A90 C(D)Q2XB 40 10 30 A73 D D With auto switch With auto switch (with built-in magnet) (with built-in magnet) Microspeed cylinder Microspeed cylinder Mounting Cylinder stroke (mm) Bore size Number of auto

Note 2) This filter does not include any companion flange, companion flange bolt, and O-ring. 4 x K depth L DRAIN (): Internal dimensions for FH342 type (mm) Model Weight (kg) d A B C D E F G H J J' K L M N P Q Threaded Rc Flange SSA FH340-03 FH340-04 FH342-06 FH342-08 FH34 -10 FH34 -12 FH341-16 FH440-03 FH44 -04 FH44 -06 FH44 -08 FH44 -10 FH44 -12 FH441-16 FH441-20 FH441-24 FH540-03 FH54

D-R Note 3) Options for 2, 6, and 8 can not be specified at the same time. (Ex.) 68 Note 4) Symbols 9, D, J can not be specified at the same time. (Ex.) 9-D-J Note 5) For products with auto drain, either symbol D or J cannot be specified at the same time. 1 Indicate the required filtration rate after the symbol 1. Ex.)

50 3/4, 1 Electric entry 1(P) 2(A) Port size Manual lockout Nil 1/4 (AVL2000) 02 D type DIN connector D Rated coil voltage 3/8 (AVL3000) 03 Port size D type DIN connector with indicator light & suppressor Manual lockout Nil 3(R) DZ 1/2 (AVL4000) 04 B A G 100VAC (50/60Hz) 1 3/4 (AVL5000) 06 D type DIN connector with M12 connector, indicator light & surge voltage suppressor AVL2000 push button

Actuating force F1 is applied to the top surface of pressure regulation piston r by the pilot pressure (pilot valve assembly q: VY1 D B 00-00), and actuating force F2 is applied to the bottom surface of the piston by the port 2(A) pressure that pases through the feedback passage. Thus, the port 2(A) pressure that corresponds to the pilot pressure is established.

Inlet pressure (MPa) 14-20-5 4 Series AMG Dimensions AMG150 to AMG650 Accessory D: With auto-drain (N.O.) Drain cock: Black One-touch fitting C: With auto-drain (N.C.)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, LOCKING, ACTUATOR, CNA/CNA2 POWER LOCK CYLINDER, ND, 50MM CNA DOUBLE ACTING, 9.47987 lb

Lead wire color (grommet) Voltage Color SOL 100 VAC Blue Cylinder Xa Xb Xc Yb Ya Mode 200 VAC Red Upward High speed a DC Red (+), Black () Low speed b Downward High speed c How to use the needle Low speed d Rotate the needle clockwise to close, and counterclockwise to open.

Fieldbus interface connector layout BUS OUT: M12 4-pin socket, D-coded (SPEEDCON) No. Designation Description 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TDTransmit Data 4 RDReceive Data BUS IN: M12 4-pin socket, D-coded (SPEEDCON) No.

The used of turbine oil at temperatures lower than 0C leads to increased viscosity and may cause the valve to malfunction. d n i n i W g c e t i r o i d n e p a t e p i P Leakage Voltage It must be noted that when connecting C-R element parallel to switching element, leakage current flows through C-R element and the leak voltage increases. 2 thread to be left exposed Clamping Torque Switching

A B-1 A A-1 B B-2 B A-2 COM-A/COM B-3 COM-B/ A-3 Cable type Nil Robotic cable (Flexible cable) S Standard cable Cable color Connector D terminal no.

Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.

nut (for panel mount) Note 3) V V V V V + Option Note 1) Nr Nil Without pressure gauge V V V V V G Round type pressure gauge (without limit indicator) V Round type pressure gauge (with limit indicator) V V V V M Round type pressure gauge (with color zone) V V V V + b Pressure gauge Note 4) c Set pressure Note 5) Nil 0.05 to 0.7 MPa setting V V V V V 1 0.02 to 0.2 MPa setting V V V V V + d

L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.

To use the power of the product, the total load current must be 200 mA or less. 2.2 Communication specification HRLE Series 2-2 HRX-OM-Z015 Chapter 2 Contact input / output communication Table 2-4 Contact input/output communication terminal number PIN No.