SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, 0.56317 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, 0.62657 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, .46020 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71092%8%0.2 to 7.0 l/min0.2 to 7.4 l/min0 to 7.4 l/min3.80 V15.2 mA

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, 45.17730 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM72592%8%0.5 to 25.0 l/min0.5 to 26.3 l/min0 to 26.3 l/min5.00 V20.0 mA

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), .65408 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM75092%8%1.0 to 50.0 l/min1.0 to 52.5 l/min0 to 52.5 l/min5.00 V20.0 mA

SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM MODULE, EJECTOR (A *LQA, VACUUM SERIES, ZX MODULAR VACUUM SYSTEM, DD, ZX NOZZLE SIZE 1.3, .00000 lb

(Normally Closed)], Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: M (with Clogging Switch, 1 Point), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: G (OUT1: NPN; OUT2: External Input), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: E (Out 1: PNP; Out 2: Analog 1 to 5 V), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: M (SI units only)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: M (SI units only)

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: C4 (4mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

.: 32mm), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)