Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 2 Stations, Port Size: 03 (Rc3/8), Electrical Entry Direction: U (Plug-in L Kit U Side), Cable Length: 2 (3.0m Cable), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: None, Option 2: W (IP65 Protection Compatible)
Function: 2 (2 Position Double), Body Option: 1 (Non Plug-in Common Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 2 (200VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: L (L Plug Connector w/Lead Wire 300mm), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: LT (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C),
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: Rc, Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WAO [M8 Connector w/o Connector (IEC60947-5-2)], Lead Wire Length: None, Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread
Series: 2 (10-SV2000), Base Type: 16FD, Connector Entry Direction: 2 (Lateral), Valve Stations: 03 (3 Stations), P, E Port Location: B (Both Sides, 2-20 Stations), Pilot Type: Internal Pilot, A, B Port Size: C6 (One-touch Fitting for Ø6)
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch FLOW CONTROL. SPEED CONTROLLER. 5.00000 lb. SVD.
Size: 40 (1/2), Reverse Flow Function: K (Reverse Flow Function), Thread: F (G), Port Size: 03 (3/8), Accessory 1: D [Float Style Auto Drain (NO)], Pressure Gauge Angle: G1 (Mounting Angle 0°), Accessory 2: None, Option 1: None, Option 2: None, Option 3: None, B: B
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: LT (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °C, Bracket: R (w/Bracket), Calibration
Stations: 5 Stations, Port Size: 03 (Rc3/8), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 2 (M12, 4 Inputs)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WAO [M8 Connector w/o Connector (IEC60947-5-2)], Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WAO [M8 Connector w/o Connector (IEC60947-5-2)], Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 2 (Rear Exhaust), Thread: Rc, Port Size: 03 (3/8), Option: B (w/Bracket), Semi-standard: None
Stations: 03 Stations, Port Size: C8 (w/ø8 One-touch Fitting), SI Unit: V (CC-Link), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM)
Stations: 2 Stations, Port Size: 03 (Rc3/8), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 1 (Input Block 1 pc.), Input Block: 2 (M12, 4 Inputs)
Valve Stations: 2 Stations, Port Size: 03 (3/8), Thread: Rc, SI Unit: Q (DeviceNetâ„¢), End Plate Type: 2 (M12 Connector Power Supply, Max Supply Current 2A), SI Unit COM: N (-COM)
Stations: 3 Stations, Port Size: 03 (Rc3/8), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)]