When washing a cylinder with a brush, etc., please do not apply excessive force to the auto switchs lead wire, etc.

(Do not change.) Pin 3 Reserved. (Do not change.) OFF Pin 4 Reserved. (Do not change.) OFF When using the MECHATROLINK-III standard servo profile, set the number of transmission bytes to either 32 or 48. When using the MECHATROLINK-II-compatible profile, set the number of transmission bytes to either 16 or 32.

Nylon tube Within 0.1mm Soft nylon tube Within 0.1mm Polyurethane tube Within+0.15mm, Within -0.2mm Do not use tube which do not meet these outside diameter tolerances.

No output Reduction of the set pressure Unstable set pressure Delay in increase of the downstream pressure Operating environment Warning (1) Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. (2) Do not operate in a location subject to vibration or impact.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.

Supply rated pressure. (100 kPa to 200 kPa) Supply pressure error Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Do not use tool for mounting because the bowl may be damaged. Refer to the Check item for referential tightening torque. Referential tightening torque: 1.5 Nm Disassembly 1) Remove the bowl assembly. Hold the bowl assembly by hand and rotate counterclockwise to remove the bowl assembly.

In incorporating the element to the element guide, do not drop the element from the upper end of the element guide. Actuators Modular F.R.L.

Do not operate at pressures, temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. Please contact SMC when using a fluid other than compressed air. We do not guarantee against any damage if the product is used outside of the specification range. 2.

Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in a place subject to heavy vibration and/or shock. 3. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion.

Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiation heat. 4. Do not use in environments which exceed the ambient temperature specifications of the product. Caution 1.

Operating pressure Do not use the product beyond the operating pressure range. Do not use in locations where peak pressure exceeds the operating pressure due to water hammer, surge pressure, etc. FGC Bag filter FGF FGF Fluid release valve Tank FGH 2. Operating temperature Do not use the product beyond the operating temperature range.

Do not lift the product by holding the panel, fittings or piping. Never lay the product down for transportation. This may lead to damage to the product. Do not modify the standard product using any of the optional specifications once the product has been supplied to a customer. Check the specifications carefully before selecting an air dryer.

Do not touch the cylinder during operation. Use caution when handling a cylinder, which is running at a high speed and a high frequency, because the surface of a cylinder tube could get so hot enough as to cause you get burned. 4. Do not use an air cylinder as an air-hydro cylinder. If it uses turbine oil in place of fluids for cylinder, it may result in oil leakage. 5.

Do not use in an atmosphere where corrosive gas es, chemicals, sea water, water, or water steam is present. Do not use in cases where there is direct contact with any of the above. 2. Maintenance space Allow sufficient space for maintenance and inspection. 2. Do not use in a place subject to heavy vibration and/or impact. 3. Observe the tightening torque for screws.

Colour of cover Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

[F 0] Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction or damage to the product can result. Verify the specifications before use. [ Un i] Unit selection function 1 [ L] L/min Default settings When the flow exceeds the set value [P_1], the switch will be turned ON.

Set value Set value or 3 4 or 3 Accumulated pulse Time ( ) U P Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 4 1 2 U P Flow DOWN DOWN 4 3 DOWN Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) [F20] Setting of external input Accumulated flow external reset [F22] Setting of analogue output Free range analogue output for instantaneous flow: OFF * Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.