9.4.15 HRL200-W-40-T2 CH1 .9-19 9.4.16 HRL100/200-W-40-T2 CH2 .9-19 9.5 Pump Capacity . 9-20 9.5.1 HRL100-A/W-40 CH1 .9-20 9.5.2 HRL200-A/W-40 CH1 .9-20 9.5.3 HRL300-A-40 CH1 .9-21 9.5.4 HRL-A/W-40 CH2 .9-21 9.5.5 HRL100/200/300-A/W-40-T2 CH1 .9-22 9.5.6 HRL300-A-40-T3 CH2 .9-22 9.6 Types of Hazard Labels . 9-23 9.6.1 Positions of danger warning label .9-24 9.7 Standards . 9-25 9.8 Daily
B76 B73 I.C. 5V P P P P P P P P P P P P P P P P P 3 wire (Equiv.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.
Not applicable for types: Double rod (W), Trunnion (T), XC8, XC9, XC10, XC11, Over sized rod (XB5) with front mounts.
5 t !5 t r !9 !8 @2 w !4 !2 !0 !0 !6 !6 i u !7 o i u !7 o !3 y !1 e q !3 y !1 q @7 CXSJM20 to 32 CXSJL20 to 32 @5 i u !7 o !5 t !6 r !9 !8 @2 r !9 !8 @2 !6 o i u !7 !5 t #0 Rod cover Head cover Rod cover Head cover Parts List: Standard Piping No. Description Material No.
A F X10 Nonstandard motor Note) Frame material Nil T Aluminum alloy Stainless steel Limit switch None Nil W B contact specification 2pcs.
m For three phase 200 VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be
VE 3 Bleed port Model (Made to Order) Pressure range Note) Indication unit Connection thread VY1 Note Model MPa G43-2-01 to 02-X2 G43-4-01 to 02-X2 G43-6-01-X2 G43-7-01 to 02-X2 G43-10-01 to 02-X2 G43-2-01 to 02-X3 G43-4-01 to 02-X3 G43-6-01-X3 G43-7-01 to 02-X3 G43-10-01 to 02-X3 G43-2-01 to 02-X4 G43-4-01 to 02-X4 G43-6-01-X4 G43-7-01 to 02-X4 G43-10-01 to 02-X4 0 to 0.2 0 to 0.4 0 to 0.6
Female union Plug P. 104 DHF Use to pipe from male threaded portion such as pressure gauge. P. 106 DP Use to plug unused fitting Branch tee P. 105 DT Use to branch line from female thread of both sides 90 direction. Swivel elbow P. 106 L Use to pipe at right angle to female thread portion. Swiveled at any direction.
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 3 Input Blocks, Type of Input Block: 2 (M12, 4 Inputs), Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: L (No Flow Adjustment Valve, Rear Ported), Port Size: C4 (ø4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Indicator Light w/Surge Suppressor Non-polar), Manual Override: D (Screwdriver Operated Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Indicator Light w/Surge Suppressor Non-polar), Manual Override: None, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LN (L Plug Connector w/o Lead Wire), Surge Suppressor: U (Indicator Light w/Surge Suppressor Non-polar), Manual Override: D (Screwdriver Operated Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: 03 (Side, 3/8), Port Thread: T (NPTF), SI Unit: SD6Q (Serial Kit for DeviceNet™), End Plate: 2 (M12 Connector Power Supply, Max. Supply Current 2A), SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
(Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)