SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-20-04-00F"

Body Size: 40, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 04 (1/2), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Standard

Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: RZ (R + Z)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)

: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature

Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.

: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: °C), Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: BG (B + G), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: JN (J + N), Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: N (Non-Relieving Exhaust Mechanism), Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: Standard, Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: H (Set Nut for Panel Mount), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard

Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: 1Y (1 + Y)

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: NR (N + R)