Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 X L 40 150 Z M9BW Low speed cylinder Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Auto switch Nil Without auto switch For applicable
Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
AL Dimensions DXT334-X72-04R-04U L side U side D side Exhaust port R side Rc 1/2 supply port (L side) 2-Rc 1/2, Output port 14-9-23
Connector Pin Assignments Display unit Output -43 With unit display switching function Nil Option 1 1 Brown DC (+) M Fixed SI unit Note 1) None Nil 2 White OUT1 (PNP) Pressure unit: PSI (Initial value) With unit display switching function P Lead wire with M12 connector (5m), straight 3 Blue DC () S 4 Black OUT1 (NPN) Note 1) Fixed unit: MPa L Lead wire with M12 connector (5m), right-angled
Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" 1000 680 440 480 420 210 150 Flow rate l/min ANR (SCFM) INOUT (35.0) (23.8) (15.4) (16.8) (14.7) (7.35) (5.25) Effective area mmCv 15.2 10.4 6.7 7.3 6.4 3.2 2.3 (0.84) (0.58) (0.37) (0.41) (0.36) (0.18) (0.13) Note 1) Flow rate values are at a pressure of 0.5MPa (72 psi) and temperature of 20C (68F).
.): ø5/32" / ø1/4", Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 100 / 200, Flow Rate (Vacuum Pressure) [L/min]: 10 / 20, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2]: 750, Weight [g]: 10.5, Internal Capacity
.): ø5/32" / ø1/4", Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 100 / 200, Flow Rate (Vacuum Pressure) [L/min]: 10 / 20, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2]: 750, Weight [g]: 10.5, Internal Capacity
CQSB25-PS CQ2B32-PS CQ2B40-PS Long stroke CQSB12-L-PS CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS Seal kit includes @7, @8 and @9. Order the seal kit with the kit number.
flats Min. bore size Model T Connection port size Weight g Effective area mm2 L D KKA3S-01F-1 Rc 1/8 44.5 37.6 T 17 -02F-1 1/8 Rc 1/4 18.5 6.1 23.4 44.8 41.2 -03F-1 Rc 3/8 49.9 43.1 19 D KKA4S-02F-1 Rc 1/4 46.1 92.2 22 -03F-1 1/4 Rc 3/8 24.2 8.1 41.2 46.9 86.2 -04F-1 Rc 1/2 52.3 99.4 24 H KKA6S-03F-1 Rc 3/8 178.8 50.5 L -04F-1 1/2 Rc 1/2 30.7 11.4 81.6 56.2 191.2 30 -06F-1 Rc 3/4 169.8 57.9
) 27 79 X PE 41.5 30.5 32 R1 R2 27 P 15.5 14.5 G1/2 Electrical entry Rc1/8 PE port 19.5 (21) 19.5 Rc1/8 External pilot port (21) 31 31 5-Rc1/4, 3/8 P, A, B, R1, R2 port ( ): Rc3/8 0 1 0 1 0 1 0 1 3 position double check: VQ460 l 0 1 2 position double: VQ420 l 3 position closed center: VQ430 l 3 position exhaust center: VQ440 l 3 position pressure center: VQ450 l 181 108 73 90 50 11(A port
Tube swaged J O int rTSJ) for use with Swagelok<l type fittings 1 Digital Pressure Switch Series ZSE6/ISE6 How to Order Vacuum pressure switch Positive pressure switch ZSE68 82 27 IL ISE68 Switch type L,.,., '",..
is required 45 40.6 1.8 Acceptable (OK) * Supply pressure: 0.5 MPa, Load factor: 50% 50: 2.2 L (ANR) 45: 1.8 L (ANR) = 0.4 L (ANR) 18% reduction Air consumption Compact and lightweight (32, 40, 50, 63, 80, 100) L1 L2 JMB W2 W1 Current product (Compared with the current product (MB)) W: Width L: Overall length Weight Bore size [mm] Current product W1 [mm] JMB W2 [mm] Current product L1 [
To obtain more detailed information about operating this product, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly. approx. 1 second The flow range is displayed 10 L/min (PFM510) 25 L/min (PFM525) 50 L/min (PFM550) 100 L/min (PFM511) Indicator LED (OUT2) Indicates the output status of OUT2. LED is ON (Red) when OUT2 is ON.
AS2201FE-01, AS2211FE-01 AS2301FE-01, AS2311FE-01 AS2201FE-02, AS2211FE-02 AS2301FE-02, AS2311FE-02 AS3201FE, AS3211FE AS3301FE, AS3311FE Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-F Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) TMH ASD AS AS-FE AS-FE Number of needle rotations Number of needle rotations Number of needle rotations
Approx. 1 second M3 x 8 L Water proof seal (accesorys) Measurement mode 4 L/min 40 L/min 100 L/min 16 L/min 250 L/min Panel Be sure to select the correct sensor to be connected. Caution *: The panel mount adapter can be rotated through 90 degrees for mounting. *: The panel mount adapter should be fixed firmly with screws. Otherwise, fluids such as water may enter.
Refer to the CKZT S-X2797 (page 3) for dimensions other than those shown below. 47 42 20 (Black) 4 130 F . ax M 55 Handle position: Right Unclamping position Handle position: Left Bore size Arm opening angle F 25 90 110 105 126 32 90 110 105 126 4 CKZT -X2797 -X2798 Dimensions: Clamp Arm CKZT25-A000 S-X2797 C R L L: Left 26 18 52 40 16 C: Center R: Right 200.1 2 x 4H7 through 200.02 (8) 28
Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator