Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]

S 1 0.53 28 2.511 48 418 6.531.5 6.531.5 10 FKM1.310 3/s Pam -11 FKM1.310 KFNW KFNW KDN SUS316L,SUS304,FKM 2 MPa G 0.40.7[ ] 46 200 360 660 1350 3000 5150 3 3 cm O.5MPa 2.5 12 15.5 30 42 54 54 M5 Rc1/8 Rc1/4 [kg] 0.5 1.2 1.8 3.4 5.6 11.5 20 1 2 [Y-VAC2] 5 3 1 1mm 32 L/SP=0.1MPa 30 6 P11) 28 XLD-100 XLD-160 L/s () P=0.1MPa 26 24 22 20 XLD-63 XLD-80 18 16 14 XLD-50 12 10

Amount of grease Piston rod L Fully extend the piston rod L=10 to 15mm (per 100mm of piston stroke) e.g.) For 200mm stroke, L = 20 to 30mm * Apply grease evenly over the piston rod base. Grease package No. GR-S-010 (10g) GR-S-020 (20g) After applying grease, operate the piston rod 2 to 3 times to spread the grease evenly over the full stroke of the piston rod. 2.

Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection PA14 0 1(+Counter motors side) Load to motor inertia moment ratio PB06 7 7 Function selection E-3 PE41 0 0 LEFS25(L,R)T6 LEFS32(L,R)T7 LEFS40(L,R)T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

(Nm) L(mm) MHM-16D M3x0.5 0.63 6 MHM-25D M4x0.7 1.5 8 MHM-32D M5x0.8 3 10 MHM-50D M6x1 5.2 12 (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 -7- 2-3. 40 2-4. () 5 5 P-01-11 -8- 2-5. 1.52 2-6. 1 ()ISO VG320 (SDS) -9- 2-7. 1) 1) 2) 3) 12mm -10- 2 C3 C1 C2: C3 D-M9V D-M9WV D-M9AV D-M9 D-M9W D-M9A D-P3DWA A B E G A B E G L A B E G L D F H MHM-16D 9.1 9.1 5.6 4.6 8.1 12.8 11

Dimensions Meter-out type Meter-in type F E D B A C J G K H L B Model A MIN. MAX. MIN. MAX.

C J G5-S Air-hydro Converter: CCT40 CV MVGQ 50 M32 x 2 Lube-plug CC Rc 1/4 Air port size RB J D-X 20Rc 1/4 Oil port size Data L Dimension (Effective oil level stroke) (mm) Effective oil level stroke (mm) 50 100 150 200 300 L 213.5 263.5 313.5 363.5 463.5 10-17-9 10 Valve Unit Series CCVS/CCVL How to Order CCV S 1 1 1 U1 Suffix S Single valve Valve unit size Unit for CC63 (Unit mounted to

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) 2, Preparation of OUT1 device Prepare the sensor for which OUT1 is to be set. ON OFF Selection of Pressure range, Output style, Response time and Pressure setting method.

Slave1 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 6320 01 20 (Object 6320h Sub-Index 1, length 32-bit) 1600h_sub2 = 6320 02 20 (Object 6320h Sub-Index 2, length 32-bit) Slave2 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 0007 00 20(Object 0007h (Unsigned 32) Sub-Index 0, length 32-bit) 1600h_sub2 = 6320 01 20(Object 6320h Sub-Index 1, length 32

Air consumption(Note 4) 1.0 or less [Measuring conditions: supply pressure 1.0 MPa, set pressure 0.2 MPa] [L/min(ANR)] Ambient temp. and Standard product: -5 to 60 Fluid temperature With digital pressure switch: 0 to 50 [OC] (No freezing) Port size 1/8 Pressure gauge port size 1/8 [2 ports] Weight [kg] Note 5)0.13 (Note 1) When there is no flow rate on the outlet side.

Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 (CCW) to 1(CW). Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -24- The origin offset means the value of the origin.

Flow Rate and Effective Area AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values

/4 Piping port size NPT 1/8, 1/4 Pressure gauge port size 435 (3.0) Proof pressure psig (MPa) 290 (2.0) Maximum operating pressure psig (MPa) ARX20-N02 7~120 (0.05 to 0.85) Standard Regulating pressure range psig (MPa) 7~45 (0.05 to 0.3) Low pressure Fluid Air ARX20-N01BG Ambient and fluid temperature 23~140F ( 5 to 60C) (with no freezing) Weight lbs (Kgf) .24 (0.11) How to Order ARX2 0 01

Features 2 Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Pressure sensing range High pressure [0 to 1MPa] Vacuum [0 to 101kPa] Low pressure [0 to 101kPa] Compound pressure [101 to 101kPa] 0 1 2 3 Option Without cable Nil Sensor cable (3m) M5 Port size L M5 x 0.8 Options Sensor cable (3m) + Connector (1 pc.)