Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.034 lb
frequency [Hz] 70 50 150 100 Valve Construction 2-position single 2-position single Standard 5-port specification Made to Order 3-port specification (-X1) q w 3 (EB) 1 (P) 5 (EA) 3 5 1 3 5 1 2 4 2 4 Component Parts No.
No gauge port No pressure gauge No code 0 V3 L 1 H 2 4 Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 1000mm, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 1000mm, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 1000mm, CE Compliant: CE Compliant