Field-wireable #1 PCA-1557730 Field-wireable connector (M8) 35.4 Terminal no. Wire color 1 3 4 Black Brown Blue 1 3 12 4 M8 Width across flats 11 Wiring Plug connector pin assignment #2 PCA-1557743 Field-wireable connector (M12) 55 Terminal no.
1 ARM Diaphragm (B) e w r y Exhaust Bleed w ARP Diaphragm (C) SUP(1) OUT(2) SUP(1) OUT(2) OUT(2) SUP(1) Exhaust Valve IR u !0 !0 !2 t r !
Note 7) This product conforms to the CE mark. 15 Digital Flow Switch Series PF2W For Water How to Order C PF2W5 20 03 Remote Type Sensor Unit Flow rate range 04 20 40 11 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to 100 l/min Option (Refer to page 35.) None e-con connector x 1 pc. Nil C Thread type The cable and connector are shipped unassembled.
IN20267 PRODUCT NAME Ethernet MPC Ethernet/IPTM MODEL / Series / Product Number MPC Multi Position Cylinder MPCXX-XXX-XXX-XX-DUT01607 1 - IN20267 2 - IN20267 Table of Contents 1. Table of Contents . 3 1. Safety Instructions . 5 2. About this Manual . 10 3. MPC . 10 3.1. Purpose . 10 3.2. Terminology . 11 4. Product Summary . 12 5. How to Order . 13 6. Accessories . 13 6.1.
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,
Panel mount adapter Sensor connector ZS-28-C 1 pc. Note) Options are shipped together, but not assembled. Panel mount adapter ZS-27-C With M3 x 8 l (2 pcs.)
By changing the port plug into a fitting, it can be used as the 5 port single solenoid valves, too. 1 2 3 1 2 3 0 1 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 2 2 2 2 0 0 0 0 2 2 2 2 Base Mounted VQZ 85 ,N.C./VQZ 95 ,N.O. 1 1 1 1 3 3 3 3 1 1 1 1 3 3 3 3 3 port valves have the same external appearance as the 5 port valves.
In the case of diodes, the residual voltage is approximately 1 V. 1. Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit.
Dimensions Dimensions Model P1 A B C D E F G H J K M N AR20S 1/4 68 66.8 73 26 27 17.5 26.5 20 2 54 56.7 55.6 AR30S 3/8 81 86.5 79 31.5 32.5 21.5 30.5 26.5 3.5 67 62.7 69.1 AR40S 1/2 98 91.5 83 40.5 41.5 25.5 35.5 35 84 66.7 86.6 AR50S 1 118 125 90.5 50 51 32 43 45 104 74.2 105 The dimension of B is the length when the regulator knob is unlocked. 22 - Revision history 1 Correction of errors
Also, crimp the lead wires and sockets securely. 1.
Trouble Possible cause Countermeasures 1. Between valve and base 1-1) Looseness of clamp screw or mounting bolt. Give more torque to clamp screw. VQ1000 : 0.250.35Nm VQ2000 : 0.50.7Nm If the damage is seen on the gasket, replace with new gasket.
How to wire DIN terminal 1. Disassembly 1) After loosening the screw (1), then if the housing (4) is pulled in the direction of the screw (1), the connector will be removed from the body of equipment (solenoid, etc.). Exploded view 2) Pull out the screw (1), then remove the gasket (2) . 3) On the bottom part of the terminal block (3), theres a cut-off part (indication of an arrow) (3a).
Compatible cable Cord O.D.:3.5 to 7 (Reference) 0.5mm2, 2-core or 3-core, equivalent to JIS C 3306 Caution Caution One-touch fittings Tubing attachment/detachment for One-touch fittings 1) Attaching of tubing 1. Take a tubing having no flaws on its periphery and cut it off at a right angle. When cutting the tubing, use tubing cutters TK-1,2 or 3.
Q 50 R 88 S 3.2 AM 1 2 3 4 , 9 36 205 19 100 106 3 106 10 AMF450 212 22 107 106 3 106 10 36 221 21 10 14 9 90 55 110 50 88 3.2 1 Misc. , , , 1 1 4.5 4.5 6 3 4 257 314 406 30 40 30 10 15 15 16 20 24 9 11 13 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 44 66 96 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AMF550 AMF650 AMF850 1 2 1 2 1 2 1 14-20-47 7 Series
Operating temperature (C) 5 to 60C (Baking temperature 150C or less) Operating pressure (Pa) 1 x 10-6 (abs) to 0.2 MPa (G) Orifice diameter (mm) 3 Main air supply 4.6 Effective area (mm2) Initial air supply 0.2 to 4.6 Internal 5 x 10-9 At normal temperature, excluding gas permeation Leakage (Pam3/s) External 1.3 x 10-11 At normal temperature, excluding gas permeation Fitting 1.3 x 10-11 1.3
1-1 Accessories Pressure gauge (GZ43,GZ33)or pressure switch (ZSE30A)-1 piece Gauge nut (with O-ring)-1 piece Note) The gauge nut is mounted on the pressure gauge or pressure switch.
How to order XGTP 3 1 2 50336 1 C N End lock Nil : OPEN/CLOSE end lock N : None Auto switch and the connector (See Table 1) Gate seal material 1: FKM 2: Kalrez4709 Kalrez is a registered trademark of E. I .du Pont de Nemours and Company or its affiliates.
MH*-OMZ0001 PRODUCT NAME Toggle Type Air Gripper MODEL / Series / Product Number MHT2-32DZ MHT2-40DZ MHT2-50DZ MHT2-63DZ Contents Safety Instructions 1. Product Specifications 1-1. Specifications 2. Operating method or operation 2-1. Design Precautions 2-2. Selection 2-3. Mounting 2-4. Air supply 2-5. Piping 2-6. Operating environment 2-7. Lubrication 3. Maintenance 3-1.
(IR1000:F.S.=0.2MPa,IR1010:F.S.=0.4MPa,IR1020:F.S.=0.8MPa) ) F.S. (2) (3) (4) 0.010.8MPa(IR1000 0.005MPa) 1 IR1000 IR1010 IR1020 [MPa] MAX. 1.0 [MPa] () 0.05 [MPa] 0.0050.2 0.010.4 0.010.8 0.2% 0.5% 4.4L/min(ANR) [1.0MPa ] -560 Rc1/8 Rc1/8 [2 ] 0.14kg (1) (0.05MPa) (2) IR1000:0.2MPa (3)2 ON-OFF () (4) -4- (C)2 (C) (A) (A) (C) (A) (C) BLEED SUP(1) OUT(2) SUP N
How to Order Valves How to Order Manifold Assemblies Example 4 0 5 SY 3 1 FU Single solenoid 2 position single Supply/Exhaust block (U side mounting) SY3140-5FU (3 sets) Double solenoid 5 FU Double/3 position 5 SY 3 2 4 SY3245-5FU (1 set) Series 3 SY3000 5 SY5000 Type of actuation 2 2 position double 3 3 position closed center 24VDC +COM + 1 2 3 Stations D side U side 4 3 position exhaust