No.PS-OMH0006-F PRODUCT NAME Multi Channel Pressure Sensor Controller MODEL / Series / Product Number PSE200 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 9 Definition and terminology 10 Mounting and Installation 13 Installation 13 Wiring 15 Internal circuit and wiring example 17 Setting of Function 18 Pressure Setting 22 Setting of Special
No.PS-OMU0012-C PRODUCT NAME Sensor Monitor MODEL / Series / Product Number PSE3#0AC Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 9 Definition and terminology 10 Mounting and Installation 13 Installation 13 Wiring 14 Pressure Setting 16 Outline of Settings 17 Initial Setting 18 3 Step Setting Mode 21 Simple Setting Mode 23 Function Selection
MHF2-8D MHF2-12D MHF2-16D MHF2-20D mm 8 12 16 20 MPa 0.150.7 0.10.7 oC -1060 mm 1) 0.05 120 c.p.m. 120 60 2) 1 N 19 48 90 141 8 12 16 20 () mm 16 24 32 40 32 48 64 80 65 155 350 645 85 190 445 850 3) g 120 275 650 1,225 1) 0.15mm 2) 0.5MPaL=20mm 3) 4 2 2-1 1. ( ) 2. 3. 4. 2-2. 1. 2. (1) (2) (3) 5 3. 4. 5. 6. (1) (2) ,2 , 7.
Functions . 14 3.1 Easy mode . 14 (1)Functions in easy mode . 14 (2)Tree structure of easy mode . 15 3.2 Normal mode . 16 (1) Functions in normal mode . 16 (2)Tree structure of easy mode . 18 4. System Structure . 19 5.
Cable colour: Signal Cable O.D. 6.6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) 3 Blue : 24 VDC (For control) Wire diameter (Including insulator) 1.65 mm 4 Black : 0 V (For control) 5 Gray : Not connected Min. bending radius (Fixed) 40 mm (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 7 Cable length (L) 7
For details of each setting, refer to page 17 to 18 of this manual. Please refer to the PLC manufacturer's manual etc. for details of programming and addresses. For the PLC protocol and programming refer to the relevant manufacturer's documentation.
Construction / Parts list, seal list Double acting/ Finger open Single acting / Normal open Single acting / Normal close Double acting / Finger close 5 4 12 7 1 9 10 8 16 15 14 3 2 21 11 18 19 13 20 6 17 Components No. Description Material Remarks Components 12 Needle roller High carbon chromium No.
Maintenance P. 18 4-1. Checks 4-1-1. Inspection points 4-1-2. Inspection interval 5. Troubleshooting P. 19 6. Construction P. 24 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Improper model selected 18 The number of connected products for which copying is possible is up to 10 pcs. Reduce the number to 10 pcs or less. Too many pressure switches connected Check the number of connected copy destination Pressure switches. Product failure Replace the product.
Improper model selected 18 The number of connected products for which copying is possible is up to 10 pcs. Reduce the number to 10 pcs or less. Too many pressure switches connected Check the number of connected copy destination Pressure switches. Product failure Replace the product.
Note 3) ASD330F and 430F types are made of steel. 15-9-18
Part No. 1 3 to 90 N X 8 31 TCU0425l -1-N-X6 L X 5.9 + 200 L X 5.2 + 200 1 3 to 90 N X 4 18 TCU0805l-1-N-X6 8 5 TCU0425l -2-N-X6 42 N X 8 L X 4.4 + 200 L X 3 + 200 2 3 to 90 N X 16 2 3 to 40 28 4 2.5 TCU0805l-2-N-X6 TCU0425l -3-N-X6 52 N X 12 3 3 to 63 L X 2.9 + 200 1 3 to 45 L X 5 + 200 N X 10 28 TCU1065l-1-N-X6 10 6.5 L X 5.3 + 200 L X 3 + 200 N X 6 24 1 3 to 90 52 2 3 to 35 N X 20 TCU0604l
0 t r y Aluminum NBR Resin SY i Stainless steel Aluminum NBR Steel o SYJ VQD1000-9-1 AXT632-7-13(M1.7 X 18) w SX Note) Body cannot be disassembled. VK VZ 3(R) 4(A) 1(P) 2(B) VF 1(P) VFR VP7 VP4 Valve Single Unit Option Piping plate assembly VQD1000-20A VQ VQ4 VQZ VQD VZS VFS VS Manifold style (VQD1131) can be changed to single unit style (VQD1121) by mounting plate assembly.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3 16 1 4 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 " " " " " 20 22 20 22 30 30 75 40 100 62 1 4 Metric size(2) 3 8 1 2 Note 1) Flow rate is less than 0.003 MPa of the initial pressure drop.
N4-18 NCQ2, Series NCQT 200 PSI (14 kgf/cm') -20-150.F (-25 -65"C) 2 20 inch/sec (50-500mm/sec) FEATURES 1) The NCQT Series cylinder gives a shorter, lighter and more compact package for a given stroke. 2) The unique shape enables the use of rail-mounted switches without significantly increasing the overall length. .
Series LVM CAT.ES70-30B Meeting the most advanced needs of process control Compact Direct Operated 2/3 Port Compact Direct Operated 2/3 Port Valve chamber volume Unit: l LVM09/090 LVM10 (For LVM11) LVM10/100 LVM15/150 LVM20/200 Series 18 11 20 50 84 Valve chamber volume Change in volume depending on open/closed status of valve (pumping volume) 0.01 l or less (Rocker type) Pumping volume
Construction/Replacement Parts 18 6.1. Construction 18 6.2. Component Parts 18 6.3. Replacement Parts 19 7. Exploded View of Manifold/Replacement Parts 20 7.1. Exploded View of Manifold 20 7.2. Component Parts for Manifold 20 7.3. Replacement Parts 21 7.4. Manifold Option 22 7.5. How to Increase Manifold Stations 23 8. Maintenance 24 8.1. Maintenance 24 8.2. Replacement Procedure 25 9.
(Refer to page 18) (2) P_1" and the set value are displayed in turn. (3) Press the or button to change the set value. The button is to increase vacuum pressure and the button is to decrease. Press the button once to increase by one digit, and press it continuously to keep increasing the set value.
No.PS-OML0002CN-G // ZSE30A(F) ISE30A 2 8 10 11 14 14 17 18 21 21 24 24 24 F0 26 F1 OUT1 27 F2 OUT2 30 F3 30 F4 31 F5 32 F6 34 F7 35 F8 36 37 F90 37 F97 39 F98 41 F99 43 44 47 48 49 56 56 58 -1No.PS-OML0002CN-G (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating
-12C DFinger: Through-hole mounting 16 22 14 14.6 28.6 166 MHKL2-16C Dust cover adhesion 20 40 18 16 34 314 MHKL2-20C Dust cover adhesion (Finger part only) 25 63 22 19 41 565 MHKL2-25C Dust cover caulking Note) At the pressure of 0.5 MPa, when gripping point L is 20 mm.