Nil 1/4 1 1/8 1 2 (OUT) (IN) Made to Order Caution Selection of Pilot Valve (JSXFAE/F/H common) Pilot valve orifice diameter: Special specification A For 3 mm to 5 mm Port size: 06, 10 For the pilot valve orifice diameter, 5 mm or larger is recommended. When the pilot orifice diameter is 3 mm or larger and less than 5 mm, put A to the end of the product number for made-to-order.

ABOUT REINSTALLATION . 3-7 Chapter 4 Operation/ Shutdown . 4-1 4.1 CHECK POINTS BEFORE OPERATION . 4-1 4.2 OPERATION . 4-1 4.3 STOP . 4-2 4.4 CAUTIONS FOR RE-START . 4-2 4.5 CHECK POINTS BEFORE RESTART . 4-2 4.6 CAUTIONS WHEN THE PRODUCT IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME . 4-2 Chapter 5 Checks and Maintenance . 5-1 5.1 DAILY INSPECTION . 5-1 5.2 REGULAR MAINTENANCE . 5-2 5.2.1

Flow Rate and Effective Area AS121FG AS221FG-02 AS321FG AS421FG AS221FG-01 Model AS131FG AS231FG-02 AS331FG AS431FG AS231FG-01 Universal type 3.2 6 8 10 12 3.2 6 10 4 6 8 JIS Symbol 4 4 8 10 12 Metric size 6 10 Tubing O.D. 1/8" 5/32" 1/8" 5/32" 5/32" 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 3/16" 1/4" 1/4" 5/16" Inch size 3/16" 1/4" 5/16" 3/8" Flow Direction Symbols on Body Meter-out type Meter-in

View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.

1 W DC (83 mA), 0.5 W DC (42 mA) 12 VDC Power consumption (Current) Inrush 0.5 VA (5 mA), Holding 0.5 VA (5 mA) 100 VAC Inrush 0.55 VA (5 mA), Holding 0.55 VA (5 mA) 110 VAC Inrush 1.0 VA (5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.

1/8 PA 86.3 78.3 2(A) 2(A) 63 19 Rc 1/2 n: Station n L L1 L2 Formula L1 = 41 x n + 33 L2 = 41 x n + 17 9 402 386 10 443 427 2 115 99 3 156 140 4 197 181 5 238 222 6 279 263 7 320 304 8 361 345 5-5-24

Part name Qty (1) Electric Actuator / LEF Series 1 (2) Driver / LECS Series 1(in case with driver) (3) Motor cable Pre-installed (1) (in case with cable) (4) Encoder cable (5) Lock cable (6) I/O Connector 1(in case with I/O connector) LECSA(Pulse input / Positioning) (2) Driver (3) Motor cable (4) Encoder cable (5) Lock cable DC24V Host controller, etc (6) I/O Connector (1) Electric Actuator

1 4 Note 1) Above figure is for D-A73/A80.

Inch Sizes Metric Sizes * 1/4 3/8 1/2 5/8 4mm (5/32) 6mm 8mm (5/16) 10mm 12mm 0.7 11 13 15 04 06 08 10 12 Colors Color Red White Yellow Color Black Blue Green Natural Symbol B BU G N Symbol R W Y * * Coming soon Note: 4mm tubing is suitable for use with 5/32 SMC One-Touch fittings as are 8mm tubing and 5/16 fittings PEAPP08 8 (5/16) 5 38 PEAPP12 12 9 63.5 PEAPP66 6 4 31.8 PEAPP10 10 5 51

residual voltage : 1V or less ISE401 T1-26 1MPa Analog output 1~5(+ 5%F.S.), load impedance: 1k ISE401 T1-65 (145PSI) Type PNP output PNP open collector 80mA 1 When handling the switch, hold the body, not the w i re .

LG1H/ Aluminum body LG1TH/ Stainless steel body LJ1 LG1 LC1 LX LC6D/LC6C Switches 50 10 10 50 Horizontal load 100% Horizontal load 50% 20 10 20 10 Horizontal load 100% Horizontal load 50% Amount of deflection m Amount of deflection m 500 1000 1000 500 200 100 200 100 50 20 50 20 10 10 5 5 Lateral load 100% Lateral load 100% 0.5 1 2 0.5 1 2 Lateral load 50% Lateral load 50% Horizontal empty

Refer to 5. Pairing of wireless unit (Page 69) for the registration procedure. (1) (4) (2) (5) (3) (1) Registered slave Details of the registered slave. Details of the registered slave Description Content Wireless channel Wireless master channel used when the wireless slave was registered.

Refer to 5. Pairing of wireless unit (Page 69) for the registration procedure. (1) (4) (2) (5) (3) (1) Registered slave Details of the registered slave. Details of the registered slave Description Content Wireless channel Wireless master channel used when the wireless slave was registered.

VZ22 20 Rc 1/8 VZ22 30 Rc 1/8 (Example) VV3Z2-20-081 (8 stations) VV3Z2-50081-C6 (8 stations) VZ212-1G-M5 5 pcs. VZ215-5M5 pcs. VZ212-1G-M5 2 pcs. VZ215-5M3 pcs. VVZ200-32A-1 1 pc.

MVGQM12-30-Z73-B 1 SFJ3130-5LZ-MA 1 For the applicable auto switch model, refer to page 10-16-5. Auto switches are shipped together, (but not assembled). Lead wire length for auto switch Cylinder stroke (mm) Refer to Standard Stroke on page 10-16-5.

Minimum Auto Switch Mounting Stroke (mm) Auto switch model Bore size (mm) D-A9 A9V D-M9 D-M9V D-F9W D-F9WV D-F9BAL Number of auto switches 2 pcs. 10 5 15 10 20 10 15 20 1 pc. 5 5 15 5 20 10 15 2 pcs. 10 5 10 10 20 10 10 25,32,40,50 1 pc. 5 5 10 5 20 10 10 2 pcs. 10 5 10 10 15 10 10 63 1 pc. 5 5 10 5 15 5 5 Besides the models listed in How to Order, the following auto switches are applicable

PNP 1~5 V F PNP 4~20 mA G NPN H PNP J 1~5 V 1~5 V K 4~20 mA 4~20 mA OUT2 C (1) T V + (2m) N M L/min L G gal/min gal F gal/min gal J L/min L GFJ : 1[L/min]0.2642[gal/min] 1[gal/min]3.785[L/min] []=9/5[]+32 15 V PF3W5--1(T) -9No.PF-OMN0011CN-C C (1 ) T V -10No.PF-OMN0011CN-C / ZS-26-B ZS-26-C ZS-26-01 ZS-40-W 2 m (e-con) ZS-28-CA-4 1 ZS-40-Y 10 -11No.PF-OMN0011CN-C

1 . i-2 i-2-2 . i-3 i-2-3 . i-3 i-2-4 . i-3 i-2-5 . i-3 i-2-6 . i-4 i-2-7 . i-4 i-2-8 . i-5 i-2-9 . i-5 i-3 . i-6 i-4 / . i-7 1 1-1 . 1-1 2 2-1 . 2-1 2-2 . 2-1 2-2-1 . 2-1 2-2-2 . 2-2 2-2-3 . 2-2 2-2-4 . 2-2 2-2-5 . 2-3 2-3 . 2-4 3 / 3-1 . 3-1 3-2 . 3-1 3-3 . 3-2 3-4 . 3-2 3-5 . 3-2 3-6 . 3-2 4 4-1 . 4-1 4-2 . 4-1 4-2-1 . 4-1 4-2-2 . 4-1 4-2-3 . 4-1 5

Auto switch . 20 5.Operating method or operation . 21 5-1Precautions for Design . 21 5-2. Installation . 22 5-3. Wiring example to robot controller (common to NPN/PNP) . 28 5-4.YASKAWA Plug & Play Kit . 29 5-4-1. Installing YASKAWA Plug & Play Kit . 29 5-4-2. Tool Presets . 34 5-4-3. Utility Window . 35 5-4-4. Magnet Gripper Integration Window . 36 5-5. Air supply . 40 5-6.