Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Switch output T Temperature characteristics Indicates the change in the display value caused by ambient temperature changes. U A function to select display units other than the international unit (SI unit) specified in the new Japanese measurement law. The product is not equipped with this function.
Internal voltage drop K Key-lock function This function prevents the set value from being changed by mishandling. M Maximum applied voltage The maximum voltage that can be connected to the output of an NPN device. Maximum load current The maximum current that can flow to the output (output line) of the switch output.
V Voltage dV dt = Voltage ratio Voltage rise rate on zero-cross point dV t Time dt HRLE Series 3.3Installation Procedure 3-11 HRX-OM-Z002 Chapter 3 Transport and Set Up Power supply specifications, power supply cable and earth leakage breaker Prepare the power supply shown in the following table.
L M N O P Q R S T ASCII code 55H 56H 57H 58H 59H 5AH Character used U V W X Y Z HEF002-A6 3-9 Troubleshooting 4 Troubleshooting The table below shows the solutions for the problems.
L M N O P Q R S T ASCII code 55H 56H 57H 58H 59H 5AH Character used U V W X Y Z INR-244-831 3-9 Troubleshooting 4 Troubleshooting The table below shows the solutions for the problems.
250 300 350 400 450 500 600 700 800 900 1000 Product weight[kg] 3.6 3.8 4.0 4.2 4.5 4.7 4.9 5.1 5.3 5.5 5.9 6.3 6.7 7.1 7.5 0.53 Additional weight with lock[kg] LEKFS40 Series Stroke[mm] 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 Product weight[kg] 5.5 5.8 6.1 6.4 6.7 7.0 7.3 7.6 8.2 8.8 9.4 10.0 10.6 11.2 11.8 0.53 Additional weight with lock[kg] 4 - 2How to order L E K
Example) Step data of the controller setting kit [Normal mode] Speed Position Accel Decel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn No. Move mm/s mm mm/s2 mm/s2 mm/s mm mm mm 0 Fixed value Fixed value Fixed value Fixed value Fixed value 60 50 30 100 18.00 22.50 0.5 1 63 *1) Available only for driver's version V1.60 or more.
Station number T A resistor mounted on both ends of wiring for connecting equipment to field bus. It prevents reflection of a signal at the end and subsequent disturbance of the signal. Terminating resistor Total of station Total number of occupied stations among the all slave stations connected with CC-Link.
(A serial-to-parallel converting unit) SI unit T A resistor mounted on both ends of wiring for connecting equipment to field bus. It prevents reflection of a signal at the end and subsequent disturbance of the signal.
T A resistor mounted on both ends of wiring for connecting equipment to field bus. It prevents reflection of a signal at the end and subsequent disturbance of the signal.
T The temperature characteristics show how much temperature affects the switch. We show the temperature characteristics for 0 to 50[oC] or -5 to 50[oC] based on data at 25[oC]. Ex.)
Select a cylinder so that Ek does not exceed the allowable kinetic energy shown in T able 1.
Description Note Body Valve guide Piston Bonnet Handle Adjusting spring Valve Material VEX PBT Brass Polyacetal Brass Brass Steel wire Brass q w e r t y u Replacement Parts Electroless nickel plated AW Mounting/Adjustment No.
1 3 Port Air Operated Valve Series VPA3145/3165/3185 How to Order SA 04 4 5 1 VPA3 VA Thread type SA VPA Air operated valve Nil Rc G NPT NPTF F N T VA 1 Number of pilot VM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size (IN, OUT port) Single Port size Rc
Size: 1 (ø0.7), 1st Selection Supply Valve and Release Valve: K (N.C.
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 20mm, Water Resistant: None, Port Thread: TF (Bore 20: M5 Thread, Bore 32 to 50: G), Stroke: 15mm, Action: T (Single Acting/Spring Extend), Rod End: K (Chamfered), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 2 (200VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4)
Mounting style Basic style Foot style Rod side flange style Head side flange style Single clevis style Double clevis style Center trunnion style B L F G C D T Tubing material Nil F Aluminum tube Steel tube Auto switch Nil Without auto switch Auto switches are not available with steel tube. Select applicable auto switch part numbers from the table below.