This energy saving design reduces the amount of heat exhausted by the dryer and can reduce power consumption during periods of reduced demand. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation; Max. inlet air temperature: 140°F (60°C); Max. flow at rated conditions: 1,059 scfm 30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard
The CA2 is available in 40, 50, 63, 80 and 100 bore sizes and is RoHS compliant. XB6 High temperature ambient range -10°C to 150°C; XC5 High temperature ambient range -10°C to 110°C; Double acting single rod; Bore sizes: 40, 50, 63, 80, 100mm; Options include pivot backet and/or knuckle joints
With an improved auto drain and standard dust filter, these units will provide years of reliable service. *** These units are not available for use in the United States or Canada *** EC Directive compliant with CE marking for use in Europe, Asia and Oceania; 50 Hz operation ; Max. inlet air temperature: 149°F (65°C); Max. flow at rated conditions: 565 scfm 960 m³/hr (ANR) @50°F (10°C) PDP
Cooling capacity: CH1= 9, 19, 26 or 37kW (oscillator); CH2= 1kW (optical system); Power Supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase; Power Supply "40": 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase; Temperature set range: CH1 = 15 to 25°C, CH2 = 20 to 40°C; Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C; Refrigerant: R410A; Communication: contact/analog I/O; Serial RS
Total cooling capacity: 9.5kW (air)/11.0kW (water) (CH1 oscillator, CH2 optical system combined); Power supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase; Power supply "40"; 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase; Temperature set range: CH1 = 15 to 25°C, CH2 = 0 to 15°C; Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C; Refrigerant: R410A; Communication: contact/analog
Series IDF*F refrigerated air dryers are larger units with improved ambient (113°F/45°C) and inlet (140°F/60°C) air temperatures. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation ; Max. inlet air temperature: 140°F (60°C) ; Max. flow at rated conditions: 1,059 scfm (30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size
This energy saving design reduces the amount of heat exhausted by the dryer and can reduce power consumption during periods of reduced demand. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation; Max. inlet air temperature: 140°F (60°C); Max. flow at rated conditions: 1,059 scfm 30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard
Cooling capacity: CH1= 9, 19 or 26kW (oscillator); CH2= 1kW (optical system); Power Supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase; Power Supply "40": 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase; Temperature set range: CH1 = 15 to 25°C, CH2 = 20 to 40°C; Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C; Refrigerant: R410A; Communication: contact/analog I/O; Serial RS-232C
With an improved auto drain and standard dust filter, these units will provide years of reliable service. *** These units are not available for use in the United States or Canada *** EC Directive compliant with CE marking for use in Europe, Asia and Oceania; 50 Hz operation ; Max. inlet air temperature: 149°F (65°C); Max. flow at rated conditions: 565 scfm 960 m³/hr (ANR) @50°F (10°C) PDP
Total cooling capacity: 9.5kW (air)/11.0kW (water) (CH1 oscillator, CH2 optical system combined); Power supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase; Power supply "40"; 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase; Temperature set range: CH1 = 15 to 25°C, CH2 = 0 to 15°C; Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C; Refrigerant: R410A; Communication: contact/analog
The CA2 is available in 40, 50, 63, 80 and 100 bore sizes and is RoHS compliant. XB6 High temperature ambient range -10°C to 150°C; XC5 High temperature ambient range -10°C to 110°C; Double acting single rod; Bore sizes: 40, 50, 63, 80, 100mm; Options include pivot backet and/or knuckle joints
range (C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ001-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?
range (C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ001-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?
range (C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ002-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?
range (C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ004-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?
range (C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-W1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?
1) (C)Cooling capacity Note 3) (kW)Heating capacity Note 3) (kW)Temperature stability Note 4) (C)Pump capacity Note 5) (MPa)Rated flow Note 6) (l/min)Flow setting range Note 7) (l/min)Main tank capacity Note 8) ( l )Sub-tank capacity Note 9) ( l )Port sizeWetted parts materialTemperature rangePressure rangeRequired flow Note 10) (50/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunications
1) (C)Cooling capacity Note 3) (kW)Heating capacity Note 3) (kW)Temperature stability Note 4) (C)Pump capacity Note 5) (MPa)Rated flow Note 6) (l/min)Flow setting range Note 7) (l/min)Main tank capacity Note 8) ( l )Sub-tank capacity Note 9) ( l )Port sizeWetted parts materialTemperature rangePressure rangeRequired flow Note 10) (50/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunications
C)Cooling capacity Note 3) (kW)Heating capacity Note 3) (kW)Temperature stability Note 4) (C)Pump capacity Note 5) (MPa)Rated flow Note 6) (l/min)Flow setting range Note 7) (l/min)Main tank capacity Note 8) ( l )Sub-tank capacity Note 9) ( l )Port sizeWetted parts materialTemperature rangePressure rangeRequired flow Note 10) (50/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunications
size 41 IN OUT A B C D Model Port size SRP111-M5 M5 x 0.8 14 23.5 30 30 C D SRP111-01 Rc 1/8 15 22.5 40 40 873 SRP Series Made to Order Specifications: Please contact SMC for detailed dimensions, specifications and lead times.