Suction flow rate of vacuum suction type (Reference values) Specifications 6 10 Bore size mm Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Piston speed Cushion Stroke adjustable range Port size Air (Non-lube) Size Suction flow rate l/min (ANR) 6 10 1.05MPa 7 15 0.7MPa 0.15MPa 0.1MPa 10C to 60C (With no condensation) 30 to 400 mm/s Rubber
Application Weight (g) Actuator Model Polyacetal roller 300 310 320 320 330 420 410 420 400 Basic VFM250-02-00 Mechanical operation Manual operation VM-08D VM-06DS VM-06D VM-05D VM-02CS VM-02C VM-01CS VM-01C Roller lever VFM250-02-01 VFM250-02-01S Hard steel roller One way roller lever VFM250-02-02 VFM250-02-02S Polyacetal roller Hard steel roller Straight plunger VFM250-02-05 Polyacetal
number 4 2 1 3 L2 L1 (n-1) x 27 27 36.5 21 56 56 2 21 98 Indicator light Manual override 173 (Double dual 3-port) 139.5 (Single) 188.5 (3-position) 157.5 14 14 14 14 PWR 131 115 COM series EX500 12 12 12 12 SMC 8 SI unit 4 x M5 mounting holes Formula: L1 = 27n + 85, L2 = 27n + 130 n: Stations (Maximum 16 stations) Dimension (mm) 7 L n 9 328 373 112 157 1 166 211 301 346 8 274 319 10 355 400
For a 15 orifice (VXD242/Port size 1/2), P 0.16 MPa, for a 20 orifice (VXD252), P 0.055 MPa, for a 25 orifice (VXD262), P 0.032 MPa 1,000 Port size 2 50 Cv = 49 VX2 Port size 1 1/2 40 Cv = 31 500 400 Port size 1 1/4 35 Cv = 23 Port size 1 25 Cv = 12.5 VXK 300 Port size 3/4 20 Cv = 9.5 VXD VXD 200 VXZ Flow rate Q [L/min] Port size 1/2 15 Cv = 5.5 100 VXS Port size 3/8 15 Cv = 4.5 VXB 50
Use a vacuum ejector with a high suction flow rate. 400 Model Selection Condition & Description of improvement Contributing factor Countermeasure Initial adsorption problem (During trial operation) Pressure drop of vacuum piping is large. Reconsider vacuum piping. Use a shorter or larger tube (with appropriate diameter).
0.019 0.077 0.173 0.307 0.483 0.81 IT,lmtig 400 0.017 0.068 0.154 0.273 0.427 0.72 35~ 0.Q15 0.060 0.135 0.239 0.374 I 0.63 " . > JOCt 0.013 0.051 0.115 0.205 0.320 0.54 , , I?a:
MPa Deionized water (Pure water), N2 5 to 60C 10 cm3/min or less (fluid: water) 0.24 Maximum operating pressure (pilot pressure) Fluid Ambient and fluid temperature Valve leakage Tubing Integrated fittings With nut 0.08 1.2 Weight (kg) 0.10 0.28 1.3 Particulate Generation Characteristics Flow-through Characteristics Particle concentration (particles/mL) Particle diameter: 0.1 m or larger 400
load W (N) 100 200 200 80 80 63 100 100 63 50 40 50 40 32 32 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Stroke St (mm) Stroke St (mm) Bore size (mm) Cylinder stroke (mm) Weight Unit: g 15 10 5 100 75 50 45 40 35 30 25 20 482 32 329 308 587 287 267 246 225 204 184 142 163 616 40 432 409 736 386 362 339 316 293 270 224 247 982 50 690 653 1170 617 581 545 508 472 436 400
Weights (g) Vane type Single vane Double vane Model CRB2BW40-S CRB2BW10-D CRB2BW15-D CRB2BW20-D CRB2BW30-D CRB2BW15-S CRB2BW20-S CRB2BW30-S CRB2BW40-D CRB2BW10-S Rotation 90 180 180 90 100 270 180 90 270 270 180 270 180 90 90 90 270 90 100 90 100 90 100 90 100 Body of rotary actuator 26.3 26.0 376 400 446 25.7 49 387 365 48 105 103 198 50 106 203 193 42 43 57 60 121 144 223 243 Flange assembly
Inlet air temperature Correction factor Air flow (l/min (ANR)) Model 50C 70C 100C 41.5 43 45.5 37 43 49.5 37 43 45.5 37 42 43.5 40 44 46 39.5 43 44.5 41 43 45.5 A B C A B C A B C A B C A B C A B C A B C 35.5 36 36.5 33.5 36 38 33.5 36 36.5 33.5 35 36 34.5 36 37 34.5 35.5 36 34.5 35.5 36 38.5 40 42 36 40 45.5 36 40 42.5 36 40 41 38 40 42.5 38 40 41.5 39 40 42.5 200 300 400
Allowable Kinetic Energy and Rotation Time Adjustment Range CRA1 P. 11-8-12 to 11-8-24 CRQ2 Stable operational rotation time adjustment range Allowable kinetic energy MSQ Size Allowable kinetic energy (mJ) Cushion angle With air cushion Rotation time s/90 Without cushion Rubber bumper MRQ 10 0.25 0.2 to 0.7 15 0.39 0.2 to 0.7 D40 20 120 0.2 to 1 25 2040 30 250 0.2 to 1 48 40 40 400
Cushion adjustment (Relief adjustment) man-hours are the same as the adjustment (cushion needle adjustment) for general purpose cylinders. 350 High power cylinder 300 General purpose cylinder (SMC Series CG1) Buffer capacity [kgf cm] Quality of cushioning (RHCF40-500, Load weight 5kg, Supply pressure 0.5MPa, Horizontal operation) 250 500 3000mm/s 1000mm/s 2000mm/s 200 500mm/s 400 150 Deflection
Load A Displacement MSQ1A MSQ10 MSQB10 (Basic type) CRB2 MSQB1A (Basic type) 100 CRBU2 Displacement m Displacement m 400 80 MSQA1A (High precision type) CRB1 60 350 MSU 40 10 20 30 40 MSQA10 (High precision type) 20 CRJ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Weight (g) Vane type Single vane Double vane CRB2BW15-S CRB2BW20-S CRB2BW30-S CRB2BW40-S CRB2BW10-D CRB2BW15-D CRB2BW20-D CRB2BW30-D 90 Model CRB2BW40-D CRB2BW10-S 90 180 180 100 270 180 90 270 270 180 270 180 90 90 90 270 90 100 90 100 90 100 90 100 Rotating angle Body of rotary actuator 26.3 26.0 376 400 446 25.7 49 387 365 48 105 103 198 50 106 203 193 42 43 57 60 121 144 223 243 Flange
Weight (g) Vane type Single vane Double vane CRB2BW15-S CRB2BW20-S CRB2BW30-S CRB2BW40-S CRB2BW10-D CRB2BW15-D CRB2BW20-D CRB2BW30-D 90 Model CRB2BW40-D CRB2BW10-S 90 180 180 100 270 180 90 270 270 180 270 180 90 90 90 270 90 100 90 100 90 100 90 100 Rotating angle Body of rotary actuator 26.3 26.0 376 400 446 25.7 49 387 365 48 105 103 198 50 106 203 193 42 43 57 60 121 144 223 243 Flange
Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 20 RHC 10 MK(2) RS Q G 80 70 30 40 50 60 30 60 70 50 40 20 Point of application L (mm) Point of application L (mm) RS H A RZQ MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 MI W S 200 320 0.7 MPa 500 CEP1 0.7 MPa 280 0.2 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.7 MPa 0.6 MPa 0.6 MPa 160 CE1 0.5 MPa 240 0.5 MPa 400
B C D E F G H I J K L M N O P Symbol Model A ARM2500 ARM3000 6 17 44 56 42 126.5 58 45 17 21 38 42 29 48 68 33.5 7 21 54 68 55 153.5 70 53 23.5 27.5 48.5 55 35 59 85.5 42.5 Dimensions by the Number of Stations Manifold stations 10 Model Symbol 9 8 7 6 5 4 3 2 L1 454 412 370 328 286 244 202 160 118 ARM2500 L2 442 400 358 316 274 232 190 148 106 L3 420 378 336 294 252 210 168 126 84 L1 592
75) C(D)UW6-D 44 (49) 49 (59) 53 (63) 58 (68) 62 (72) 67 (77) 76 (86) 85 (95) 94 (104) C(D)UW10-D 74 (99) 81 (111) 88 (118) 95 (125) 102 (132) 109 (139) 123 (153) 137 (167) 151 (181) C(D)UW16-D 132 (165) 145 (182) 158 (195) 171 (208) 184 (221) 197 (234) 223 (260) 250 (287) 275 (312) 301 (338) 327 (364) 353 (390) 379 (416) C(D)UW20-D 240 (294) 260 (319) 280 (339) 300 (359) 321 (380) 341 (400
258-9200-www.stevenengineering.com 11 12 Vacuum type Relieving type (With specially treated sliding parts) CX DSpecifications 10 15 20 32 25 6 Bore size (mm) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Stroke adjustable range Bearing type -X 1.05 MPa 0.7 MPa 200.05 MPa 0.15 MPa 0.1 MPa 10 to 60C (No freezing) Data 30 to 400
Therefore, even if the conditions given above are not exceeded, the use of a shock absorber is recommended. 5 0 100 200 300 400 500 Speed (mm/s) Static Movable Weight when Stopped When Series CXT cylinder is used for moving the workpiece receptacle, such as in a stamping or press-fitting process, a vertical load will be applied to the top surface of the stopped slide block (refer to the figure