In-line 0.5 () 3 (L) 5 (Z) None (N) 3 wire (Equiv. NPN) IC A76H 5V Yes A72H A72 200V Grommet Reed switch Solid state switch A73H A73 100V 12V 5V 12V 100V or less Stroke (mm) No A80H A80 IC Relay, PLC 2 wire Refer to standard stroke on p.2.4-3. Refer to p.2.4-3 when using auto switch.
Z I M 1 G 0.2 (G) A H P 6.3 5 NN OO (Hexagon head bolt) PP (Hexagon nut) E N X (Hexagon socket head cap screw) F (Through) V (Opposite side: Same) (L) (Z) TT QQ (G) T Q U R UU (Piping port) (Opposite side: Same) (I) (L) (Z) N W C (mm) M N OO A B C D E G H I J K L NN P F Model 2-5.5 through 2-9.5 counterbore with depth 5.3 2-M4 x 0.7 with depth 6 64 25 62 23 11.5 50 28 6 12 12 30 10 M6 x 1.0
How to Order L 25 100 CG1Y Without auto switch L H7BW S 25 100 CDG1Y With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) CV MVGQ CC RB J D-X 20Data 10-4-13 14 Series CG1Y Dimensions: 20 to 100 Mounting bracket dimensions are the same as those of the low friction, double acting, single rod type of Series CG1Q. Please refer to page of Best Pneumatics Vol. 6.
s t o p p e r I n s t a l l p o s i t i o n o f e x t e r n a l s t o p p e r C auti on on usi ng exte rnal stoppe r R o t a r y a c t u a t o r w i t h A u t o s w i t c h A u t o s w i t c h s p e c i f i c a t i o n A u t o s w i t c h i n s t a l l a t i o n A u t o s w i t c h s e t p o s i t i o n I n t e r n a l s t r u c t u r e a n d o p e r a t i o n p r i n c i p l
200 VAC specification] Terminal block K L H M N J 4-13 P [200 VAC specification] Power cord outlet (17) [100 VAC specification] Power cord (mm) A B C D E F G H J K L M N P Q Port size Model IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E 69 101 270 32 21 330 413 38 150 3/8 226 410 240 15 51 232 138 24 327 125 67 304 33 73 31 36 154 21 330 473 1/2 13 453 283 275 498 455 15 270 31 80 230 32 15
K 0.2 A + Stroke M E 25, 30, 40 2 x P H effective thread depth C Q Y F 2 x 4 x OB Depth of counterbore RB 2 x 4 x OA effective depth RA J I 4 x N through 0.2 D W E M K B + Stroke L 0.2 A + Stroke M E (mm) Bore size (mm) P Stroke range (mm) RB Note) H OA A B C D E F W I Y J K L M N OB Q RA TN TF 10 39.5 M3 x 0.5 M4 x 0.7 10 to 40 31.5 6 6 ( 5.8) 29 5.5 38 4 5 5 8 20 3.5 6.5 14.5 7 16 44
IDG100S-N04-P IDG100-N04-P IDG30L-N03-P IDG50L-N03-P IDG60L-N04-P IDG75L-N04-P IDG60S-N04-P IDG75S-N04-P IDG3-N02-PS IDG5-N02-PS IDG10-N03-P IDG20-N03-P IDG30-N03-P IDG50-N03-P IDG60-N04-P IDG75-N04-P IDG1-N02-P The membrane air dryer uses hollow fibers composed of a macro molecular membrane through which moisture passes easily, but is difficult for air (oxygen and nitrogen) to pass through
PAP: Clean room LVH Note 1) 1 to 12 l for 3/8" tubing type. Note 2) The above values are for a normal temperature and using clean water. LVD Refer to the separate pamphlet P-E00-5A for further details.
MXF Calculation of resistance force f MXW San 1 (L/GP)2 (provided that L>GP) MXP Calculation of theoretical output F MG L (mm) W MGP Refer to the table of theoretical output on p.3.8-3.
min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AR20(K) Rc 1/4 AR60(K) Rc 1 AR40(K) Rc 1/2 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 00 0 5000 10 0 0 200 400 600 800 1000 2000 3000 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AR25(K) Rc 3/8 AR40(K)-06 Rc
Circuits and Wiring Examples p. 9 Options/Part Nos.
L (Example) F9BVL Note 1) Be careful for the differential of 2 color indication type D-F9BAL. Refer to "Auto Switch Hysteresis" on P.24. Note 2) Refer to P.22 and 23 for auto switch specifications.
63mm cAt N63-P 80mm cA1N80-P!
P. 64 15-2-61 Series H/DL/L/LL Male Connector: H H1 (width across flats) H2 (width across flats) Applicable tubing O.D.
Digital Flow Switch Unit Specifications Detection type Heat type Measured flow range 50 to 500 L/min 5 to 100 L/min Minimum unit setting 5 L/min 1 L/min Accumulated pulse flow rate exchange value (Pulse width: 50 [ms]) 5 L/pulse 1 L/pulse Accumulated flow range 0 to 9 L 5% F.S. or less (15 to 35C: Based on 25C) Linearity 2% F.S. or less Repeatability 5% F.S. or less (15 to 35C: Based on 25C
Real-time switch output Unit switching Hysteresis mode ON YES Display Real-time flow rate Accumulated flow OFF P-1 P-2 L/min L Real-time flow rate GPM gal (US) "P" Window comparator mode H : Hysteresis GPM = gal (US)/min H H Note) Fixed SI unit (L/min, L, m3 or m3x10) will be set for the type without the unit switching function.
6 8 34 25f8 5.5 M10 x 1.25 17 15 M24 x 1.5 1/8 81 11 3.5 5.5 143 10 46 32 8 9 40 31f8 7.5 M14 x 1.5 18 15 M30 x 1.5 1/8 87 13 3 4 159 10 53 40 10 11 48 34f8 7.5 M16 x 1.5 22 21 M33 x 2 1/4 108 16 5 0 183 16 54 8 Series CHN Dimensions Single clevis type: CHNC Width across flats B1 MM GA2 NN Rc P GB2 Rc P Rc P Cushion valve Cushion valve GB1 V T Cushion valve H1 GA1 CD Push press fitting W
(Type DZ only) 67.5 59 32 17 2 2-4.5 (Mounting hole) P mPm P 19 35 Pg.7 2-Rc 1/8 1(P) port A A A 11 20 26 49 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc 1/8, M5 x 0.8 2(A) port 19 35 n-Rc 1/8 3(R) port 47.5 11 R R P = 19 19 L Dimension n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266
(DZtype only) 67.5 59 32 17 2 2-4.5 (mounting holes) P 19 35 P Pg.7 2-Rc(PT) 1/8 (ports P) A A A 11 20 26 49 Approx. 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port R) 47.5 11 R R P = 19 19 L: Dimension table n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228